4.10
Permissible forces and torques on
the pump flanges
Fig. 5: Permissible forces and torques on the
pump flanges – pump made of grey cast iron
Installation and operating instructions Wilo-Atmos TERA-SCH
Product description
Motor power P
[kW]
Measuring surface sound-pressure level Lp, A [dB(A)]
N
2-pole
(2900 rpm)
70
18.5
70
22
72
30
72
37
77
45
77
55
80
75
80
90
80
110
80
132
80
160
80
185
81
200
81
220
81
250
83
280
83
315
83
355
81
400
81
450
81
500
81
560
81
630
-
710
-
800
-
900
-
1000
1)
Spatial mean value of sound-pressure levels within a cube-shaped measuring area at
a distance of 1 m from the surface of the motor
Table 5: Anticipated noise levels for standard pump (50 Hz)
DN
Forces F [N]
F
F
F
X
Y
Z
Each nozzle
1200
1340
1080
100
1420
1580
1280
125
1800
2000
1620
150
2400
2680
2160
200
2980
3340
2700
250
3580
4000
3220
300
4180
4660
3760
250
4780
5320
4300
400
5380
5980
4840
450
4-pole (
1450 rpm)
64
64
66
66
66
67
72
72
74
74
74
74
76
76
76
77
77
77
77
77
77
77
77
77
77
77
77
Torques M [Nm]
Σ Forces F
M
M
X
Y
2100
525
375
2480
630
450
3140
750
525
4180
975
690
5220
1335
945
6260
1815
1290
7300
2325
1650
8340
2910
2070
9380
3585
2550
en
1)
6-pole
(980 rpm)
63
63
64
64
68
68
70
70
70
70
76
76
76
76
76
76
76
78
78
81
81
81
81
8/1
81
81
-
M
Σ Torques M
Z
435
780
570
915
615
1095
795
1440
1095
1965
1485
2670
1905
3420
2385
4290
2940
5280
15