Herunterladen Inhalt Inhalt Diese Seite drucken

Wilo Atmos TERA-SCH Serie Einbau- Und Betriebsanleitung Seite 25

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Fig. 19: Checking the axial alignment with a
calliper gauge
Fig. 20: Checking the axial alignment with a
calliper gauge – circumferential check
Fig. 21: Adjusting screw A for axial safeguard
B
B
Fig. 22: Fastening screws B of coupling halves
Installation and operating instructions Wilo-Atmos TERA-SCH
Installation and electrical connection
Checking the axial alignment
NOTICE
The axial deviation of the two coupling halves must not exceed the maximum values
found in table "Permissible gaps S and S2". This requirement applies to every oper-
ating status – including operating temperature and inlet pressure.
Using a calliper gauge, circumferentially check the distance between the two coupling
halves.
ƒ
Connect the coupling halves once correctly aligned.
The tightening torques for the coupling are listed in the table "Tightening torques
for adjusting screws and coupling halves".
ƒ
Install the coupling guard.
Coupling parameter d
[mm]
80, 88, 95, 103
110, 118
125, 135
140, 152
160, 172
180, 194
200, 218
225, 245
250, 272
280, 305
315, 340
350, 380
400, 430
440, 472
Table 10: Tightening torques for adjusting screws and coupling halves
Tightening torque for ad-
justing screw A [Nm]
4
4
8
8
15
25
25
25
70
70
70
130
130
230
en
Tightening torque for ad-
justing screw B [Nm]
13
14
17.5
29
35
44
67.5
86
145
185
200
260
340
410
25