3
On Line Active Plus Kit – easy installation
Before starting, please check that you have all the components
listed above (see fi g. 1) as well as the recommended tools.
There are 7 steps to the installation.
Prior to installation, read the Technical Data (chapter 7) and
the Important Information (chapter 9). After storage and
!
transport below 0°C, the product must be stored in the open
original packaging for at least 24 hours at the stated ambient
temperatures (chapter 7) for operation.
3.1
Step 1: Selecting the carbonate hardness
(++/+) on the fi lter head
To set the fi lter head to your local carbonate hardness, fi rst carry
out a carbonate test using the supplied testing strip.
The testing strip can be found in the outer wrapping of these
Usage Instructions.
Using the testing strip:
• Let the red response fi eld of the probe soak in a glass of your
tap water for 1 second.
• After 1 minute, compare the colour of the response fi eld with
the table and read the appropriate setting from the table.
Depending on the colour of the testing strip, we recommend
setting your fi lter head as follows:
Setting
+
Red, orange,
Colour
yellow
Capacity
1000 L
German Carbonate
up to 8.5
Hardness [°dH]
English Carbonate
up to 10.6
Hardness [°eH]
French Carbonate
up to 15.2
Hardness [°fH]
Grains per Gallon CaCO3
up to 8.9
[gpg CaCO3]
Milligram per Litre CaCO3
up to 151
[mg/L CaO3]
++
Green, dark
green
500 L
above 8.5
(fi g. 2)
above 10.6
above 15.2
above 8.9
(fi g. 3)
above 151
The fi lter head is set to "++" by default. To change the setting, use
an Allen key (5 mm). Turn in the direction of the arrow until the
"+" appears in the window. To set the fi lter head when using the
On Line Active A 1000 fi lter cartridge, see chapter 4.
Alternatively, your local water supplier will provide information on
carbonate hardness.
3.2
Step 2: Programming the electronic BRITA
cartridge exchange indicator with display
A Commissioning:
Please insert the enclosed batteries (2 x AA) into the appropriate
compartment of the BRITA electronic cartridge exchange indicator
with display. A long beep will sound after insertion of the batteries.
B Initial programming with ++ or + setting (see step 1):
Important: Set the electronic exchange indicator to 90 days (with
the "++" setting) or 180 days (with the "+" setting) depending on
the setting made for the fi lter head in step 1.
Caution: Please ensure that you activate the electronic BRITA
cartridge exchange indicator with display during the day so that the
signal can start during the day.
Initial programming with 90 day setting (see fi g. 2):
a Press the DISPLAY button briefl y to activate the display. Initially,
the default setting of 90 days is displayed.
b Then press the START/RESET button briefl y to activate the
90-day timer.
c A fl ashing spot in the bottom left of the display indicates that the
timer has begun.
Initial programming with 180 day setting (see fi g. 2):
a Press the DISPLAY button briefl y to activate the display. Initially,
the default setting of 90 days is displayed.
b Press and hold the DISPLAY button and then press the START/
RESET button briefl y at the same time. This activates the setting
mode.
c To switch from 90 days to 180 days, press the DISPLAY button
briefl y.
d Wait until the indicator stops fl ashing or the DISPLAY switches
off.
e To activate the 180-day timer, briefl y press DISPLAY and then
press the START/RESET button.
f A fl ashing spot in the bottom left of the display indicates that the
timer has begun.
5
ENGLISH