Herunterladen Inhalt Inhalt Diese Seite drucken

Replacing The Fi Lter Cartridge - Brita On Line Active Plus Gebrauchsanleitung

Vorschau ausblenden Andere Handbücher für On Line Active Plus:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 47
3.7
Step 7: Commissioning
Before use, make sure that you have followed all the steps
correctly and all the parts are fi tted. Place a suitable container
under the cartridge to catch any leakages.
A Turn on the cold water supply and check the system carefully for
any leaks.
B Open the valve on your tap and rinse through until the fi ltered
water runs clear and without any bubbles (at least 2 litres).
4
Replacing the fi lter cartridge
The fi lter cartridge must be replaced when it runs out or at
latest 6 months after commissioning, irrespective of the level of
exhaustion of the fi lter system.
Read the Operating and Safety Information (chapter 9)
prior to exchange. After storage and transport below 0°C,
!
the product must be stored in the open original packaging
for at least 24 hours at the stated ambient temperatures
( chapter 7) for operation.
The fi lter cartridge can be pivoted by 90° in the wall mount
for easy removal. When the locking handle is open, the
water supply to the cartridge is interrupted and short-circuit
operation with direct water fl ow from the water inlet (IN) to
the outlet (OUT) is possible without an installed cartridge.
Replacing the On Line P 1000 (see fi g. 7):
A Open the locking handle (3).
B Activate the fl ush valve (4) and release pressure from the sys-
tem.
C Remove the exhausted fi lter cartridge (5) from the fi lter head (2).
D Insert the new fi lter cartridge (see chapter 3.5).
E Close the locking handle (3).
Optional: Inserting the BRITA On Line Active A 1000
You can also use the On Line A Activated Carbon A 1000 fi lter
cartridge with your BRITA On Line Active Plus Water Filter Kit.
First, set the fi lter head to setting C.
10
ENGLISH
The fi lter head is set to "++" by default. To
change the setting, use an Allen key (5 mm).
Turn the screw in the direction of the arrow
until you see the C symbol in the window.
Then insert the fi lter cartridge as described in
3.5.
5
Resetting the electronic cartridge exchange
indicator with display
A Press the DISPLAY button briefl y to activate the display.
B Press and hold the START/RESET button for 5 seconds until a
long beep sounds.
C The last programmed 90 or 180 day setting now appears in the
display.
D The timer starts automatically.
6
Repair
Regularly check the fi lter system for leaks. Regularly check the
hoses for kinks. Bent hoses must be replaced.
The complete fi lter system incl. hoses must be replaced after a
maximum of 5 years.
Prior to changing, read the Technical Data (chapter 7) and
!
the Operating and Safety Information (chapter 9).
Regularly clean the outside of the fi lter system with a soft, damp
cloth.
Do not use any abrasive chemicals, cleaning solutions or
!
astringent cleaning agents.
(fi g. 9)

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis