4.3
Connect the plug to the underside of the control unit
Shorten and/or lengthen cable with plug to fit. To lengthen
(max. 30m), only use the suitable cable extension set
(art. no. 80889, 80890, 80891). To shorten, proceed as
follows:
Lay cable up to connection, measure 5 cm reserve.
Cut off using combination pliers. Strip cable jacket
from approx. 3 cm before the end of the cable.
Pull the nut off the cable cutoff and push onto the
exposed wires.
Bend over the wires into the recesses in the side,
then cut off flush.
The remaining installation does not require any tools.
Connecting the (backwater flap) motor
Route the cable from the motor to the connector on the
left (next to mains connection).
Remove nut (connector) and protective cap.
Align cable arrow on arrow and push on.
Tighten the connector so that the spacer ring connects
flush. If a spacer ring is not fitted, note tightening torque
of 1 Nm.
If the torque is correct, the gap between the nut and
hexagonal body is 1-2 mm, if a spacer ring is not fitted.
34 / 148