5.14

Oil scales

To enable or disable the scales operation, proceed as
follows:
1. Call up the Main Menu.
2. Select
.
3. Select
.
4. Select Settings.
5. Select Oil Load Cells.
6. Use the Up or Down arrow buttons to select the
scales to be modified: PAG Oil scale, POE Oil
scale, UV dye scale, or Oil Drain scale.
7. Select
to enable or disable.
8. Select
to save.
5.15

Leak test vacuum time change

To change the leak test vacuum time, proceed as fol-
lows:
1. Call up the Main Menu.
2. Select
.
3. Select
.
4. Select Settings.
5. Select Default Vaccum Leak Test Time.
6. Use the multi-touch interface on the numeric key-
pad to change the value.
7. Select
to save.
5.16

Firmware update

To upgrade a firmware, proceed as follows:
1. Call up the Main Menu.
2. Select
.
3. Select
.
4. Select Settings.
5. Select Firmware Update.
6. Use the Up or Down arrow buttons to select the
desired mode.
7. Select
to proceed.
8. Follow the instructions on the display.
i
To upgrade the firmware with USB key, insert the
key into the USB port on the control panel and
display the station; while the firmware upgrade via
WiFi is necessary before connecting the station to a
WiFi network (see chapter 5.17).
Robert Bosch GmbH
Initial settings | ACS 753 | 55 |
5.17
Wifi configuration
1
Fig. 16:
USB port location
1 USB ports
1. Carefully insert the WiFi Dongle into the USB con-
nector of the station.
2. Turn on the station and pair the Dongle with the
Router on.
3. Call up the Main Menu.
4. Select
.
5. Select
.
6. Select Settings.
7. Select WiFi Configuration.
8. Select Search WiFi Networks and wait a few sec-
onds to display the available networks.
9. Select the network associated with the router with
the Up or Down arrow buttons and confirm with
.
10. Enter the router WiFi password, confirm with
and wait for the connection to be established.
i
Make use of Manual Connect function whenever
the WiFi network is not automatically detected
through the Search WiFi Networks function. Man-
ually enter the WiFi network name and password
paying attention to upper and lower cases and then
confirm with
.
11. The station informs the operator with a message
that the connection has been successfully complet-
ed and the status bar will appear
12. Select
to exit.
"
The configuration to WiFi network is completed.
i
The efficiency and quality of wireless communi-
cation may be affected by the presence of radio
disturbances. The protocol provides for handling
errors, but can cause communication problems
that sometimes require new attempts to connect.
If there are critical features that may affect normal
operation, the source of electromagnetic environ-
mental noise must be sought, reducing its intensity.