3.6.2

Settings Menu

Function
Description
Select Language
Select a language from the displayed
ones. The default language is English.
Select Units
To program the machine to display met-
ric or imperial values. The default view is
in metric system.
Date and Time
To program the current time and date in
the station.
Edit Print Header
Programs the information that appears
in the print summary every time the print
function is used.
Unit Activation
Failure to register and activate the ma-
chine within 30 days of initial start-up
causes the machine to lock and the im-
possibility to use it. Select this item in
the Settings Menu and follow the in-
structions that appear on the screen be-
fore the trial period expires.
Oil Load Cells
To enable or disable the operation of
new PAG oil, new POE oil, exhausted oil
and UV dye scales.
Default Vacuum
To change the vacuum time for the leak
Leak Test Time
test.
Set Buzzer
To enable or disable the acoustic signal.
Firmware Update
To upgrade the firmware through a USB
stick or WiFi. The display shows three
selection options:
+ Check for Update: to check if new
firmware updates are available.
+ USB Update: to upgrade the firmware
through a USB stick.
+ Wi-Fi Update: to upgrade the firmware
through WiFi network. If the station is
connected to the WiFi network and the
WiFi network is connected to the In-
ternet, the search for new updates will
automatically start.
WiFi Configuration
To configure the WiFi connection on the
station.The display shows five selection
options:
+ Search WiFi Networks: to search for
available WiFi networks.
+ WiFi Status: to display some data re-
lated to the WiFi connection used.
+ Test WiFi connection: to perform a
connection test on the wireless net-
work used by the station.
+ Disconnect current network: to dis-
able the WiFi network connection
stored on the station.
+ Manual connect: to perform manual
scan and selection of WiFi network.
Asanetwork
To activate or deactivate the Asanetwork
function.
Information can be obtained from the
service department.
Connected Repair
To activate or deactivate the CoRe func-
[CoRe]
tion. See Connected Repair [CoRe] in
the Initial Settings section.
Default N2 Leak
To change the N2 test time for the leak
Test Time
test.
Select
to return to the Setup Menu.
Robert Bosch GmbH
Introduction | ACS 753 | 49 |
3.6.3

Maintenance Menu

Function
Description
Filter Maintenance
The filter removes acids, particles and
condensate from the refrigerant. To
meet the requirements, it is mandatory
to replace the filter after 68 kg (150 lb)
of refrigerant has been filtered.
This menu item displays the remaining
capacity of the filter before the station is
stopped and stops operating. See Filter
Maintenance in the Maintenance section.
Pump Maintenance
This menu item displays the remaining
time until the next oil change of the vac-
uum pump. To obtain the best perfor-
mance from the vacuum pump, replace
the oil every time the filter is replaced.
See Vacuum pump oil change in the
Maintenance section.
ISV Purge condition Displays the pressure and temperature
in the refrigerant tank. It is used to elim-
inate incondensable gases and helps to
limit the pressure in the refrigerant tank.
Calibration Check
To check the calibration of the internal
scale. See Checking the calibration in
the Maintenance section of this manual.
Adjust Zero Offset
To reset the new PAG oil, new POE oil,
exhausted oil and UV dye scales to zero.
Display Title Info
To activate or deactivate the station
pressure and temperature
System Information Displays the revision level of the station
software.
Service Menu
Reserved for use by Bosch service cen-
ters.
Production Menu
Reserved for use by Bosch technicians
only.
Select
to return to the Setup Menu.
en
displaying.
|
1 689 989 612