Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - Abicor Binzel xFUME FLEX Betriebsanleitung

Niedrigvakuum-schweißrauch-absauggerät
Vorschau ausblenden Andere Handbücher für xFUME FLEX:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

xFUME FLEX

10 Troubleshooting

DANGER
Risk of injury and device damage when handled by unauthorized persons
Improper repair work and modifications to the product may lead to serious injuries and damage to the device. The
product warranty will be rendered invalid if work is carried out on the product by unauthorized persons.
• Only qualified personnel are permitted to perform work on the device or system.
CAUTION
• Before performing any maintenance and cleaning work, suitable safety measures must be taken.
• Maintenance and cleaning work on the device may only be carried out in areas with locally filtered forced ventilation.
• Always wear your personal protective equipment when performing maintenance and cleaning work.
• Personal protective equipment consists of protective clothing, safety goggles, a class P3 respiratory mask, protective
gloves, and safety shoes.
Observe the attached "Warranty" document. In the event of any questions and/or problems, please contact your retailer or
the manufacturer.
NOTICE
• Consult the documentation for the welding components.
Fault
Insufficient extraction volume.
External extraction system does
not start.
Dust is escaping the system.
Tab. 11
Troubleshooting
BAL.0733.0 • 2020-12-04
Cause
• Extraction arm is blocked.
• Close the extraction hood valve.
• Filter elements saturated.
• Power supply defective.
• Electrical components defective.
• Motor protective switch defective.
• Filter elements saturated.
• Service door not closed.
10 Troubleshooting
Troubleshooting
• Remove the blockage from the
extraction arm.
 6.2 Mounting the extraction arm
on page EN-10
• Bring the extraction hood lever into
the vertical position and open the
valve.
 6.4 Controlling the volume flow
on page EN-13
• Replace the filter elements.
 9.2.1 Replacing the filter pad on
page EN-18
 9.3.1 Replacing the primary
filter on page EN-19
• Check the electrical connection.
• Check cable for damage.
• Check and replace if necessary.
• Check and replace if necessary.
• Replace the filter elements.
 9.2.1 Replacing the filter pad on
page EN-18
 9.3.1 Replacing the primary
filter on page EN-19
• Close the service door.
EN - 21