9 Maintenance and cleaning
9.5 Replacing the extraction arm
CAUTION
Reduced extraction capacity
Damage to the extraction hose and leaks negatively impact extraction performance.
• Check the extraction hose regularly and replace it as needed.
Figure
Without
Without
Without
Tab. 10
Replacing the extraction hose
EN - 20
Action
1 Fold the upper end of the rubber sleeve on the extraction
hood so that the gripping clamp is accessible. Loosen the
gripping clamp screw.
2 Retract the extraction hose.
3 Cut open the cable tie.
4 Disconnect the cable connections.
5 Loosen the screw between the connector and profile tube
and remove the extraction hood.
6 Fold the upper end of the rubber sleeve on the extraction
system so that the gripping clamp is accessible. Loosen
the gripping clamp screw.
7 Remove the extraction hose in the direction shown and
replace it with a new one.
 6.2 Mounting the extraction arm on page EN-10
Perform step 5 and step 6.
 6.2 Mounting the extraction arm on page EN-10
Perform step 12 through step 18.