Detach the fitting by which the top of the filter is
EN
connected to the heater pipeline (1) .
Remove the cap by pressing down the release catch (2)
immediately below the collar and unscrewing the collar
(3), turning anticlockwise .
The two actions must be performed simultaneously
whenever the catch mechanism re-engages.
Remove the filter element (4) and clean or replace .
Do not utilize solvents to clean the filter, the element
and other components.
The use of solvents can damage plastic parts.
when replacing the filter, dispose of the old one
correctly.
Check that the rubber O-ring under the cap is not cut,
broken, out of shape and/or showing signs of wear .
If the seal needs replacing, contact an authorized
Teuco service centre.
Check that the release catch mechanism has not
suffered any damage during the operation of removing
the cap .
Do not operate the filter if the cap release mechanism
has been damaged.
Having washed and repositioned the element, or fitted a
replacement, close the drain plug (5) and repeat the
above sequence of steps in reverse order .
Thereafter:
Start the filter pump by positioning the switch on the
control panel to "MAN" .
Bleed the filter by opening the valve and waiting until
water emerges without air .
Return the switch to the "AUTO" position .