Message:
1140 – Too steep
Check wire routing
Possible cause:
– Tilt sensor has detected slope
inclination exceeding 22°
Remedy:
– Change routing of perimeter wire, block
off lawns with slope inclinations
exceeding 22°
Message:
1160 – Handle actuated
Press OK to release
Possible cause:
– The robotic mower has been lifted by
the carry handle
Remedy:
– Confirm message with OK
Message:
1170 – No signal
Switch on docking station
Possible cause:
– Docking station is switched off
– No reception of wire signal during
operation
– The robotic mower is located outside
the mowing area
– Docking station or electronic
components were replaced
Remedy:
– Switch on docking station and give
mowing command
– Check power supply to the docking
station
– Check LED on the docking station – the
red LED must be permanently
illuminated during operation (
0478 131 9954 A - EN
– Return robotic mower to the mowing
area
– Link robotic mower and docking station
(
11.15)
Message:
1180 – Dock iMOW®
Automatic docking
not possible
Possible cause:
– The docking station was not found
– The start or end of a corridor was
installed incorrectly
Remedy:
– Check LED on the docking station,
switch on the docking station if
necessary (
– Check docking (
– Check funnel-shaped entrance and exit
areas of the corridor (
Message:
1190 – Docking error
Docking station occupied
Possible cause:
– Docking station occupied by a second
robotic mower
Remedy:
– Dock the robotic mower once the
docking station is unoccupied again
Message:
1200 – Mowing motor fault
Mowing motor start not possible after 5
attempts
Possible cause:
– Dirt between carrier plate and mowing
deck housing
– Mowing motor cannot be switched on
13.1)
13.1)
15.7)
12.11)
– Mowing motor overloaded
Remedy:
– Clean mowing blade and mowing deck
(
16.2)
Clean carrier plate (
16.6)
– Set higher cutting height (
– Level out any uneven areas (holes,
depressions) in the mowing area
Message:
1210 – Drive motor fault
Wheel stuck
Possible cause:
– Overload at a drive wheel
Remedy:
– Clean the robotic mower (
– Level out any uneven areas (holes,
depressions) in the mowing area
Message:
1220 – Rain detected
Mowing interrupted
Possible cause:
– Mowing operation has been interrupted
or not started due to rain
Remedy:
– No action necessary; adjust rain sensor
if required (
11.11)
Message:
1230 – Docking error
Dock iMOW®
Possible cause:
– Docking station has been located,
automatic docking not possible
Remedy:
– Check docking, if necessary manually
dock the robotic mower (
9.5)
16.2)