Herunterladen Diese Seite drucken

Castolin Eutectic XuperMIG 2500 Bedienungsanleitung Seite 17

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

L12: Slope down.
L13: Final current.
L14: Post-Gas.
The sub-menu gives access to:
Slope up.
Base current.
Pulsed frequency.
LIGHT
PARAMETER
L11
Welding current
L12
Slope down
L13
Final current
L14
Post-Gas
-
Slope up
-
Base current
Pulsed
frequency
-
(0,0Hz =
CONTINUOUS
TIG)
S4: WELDING PROCEDURE selection button.
A light on next to the symbol confirms the selection of the
procedure.
The available procedures in the MIG/MAG modality are:
2T MIG/MAG welding:
Bring the torch close to the piece you mean to weld.
Press (step 1) and hold the torch button.
The wire advances at closing speed until it comes into
contact with the material, at this point the arc is activated
and the speed goes back to the preset value.
Release the button (step 2) in order to start the welding
completion procedure.
The supply of gas continues for a period equal to the
POST-GAS time (adjustable).
4T MIG/MAG welding:
Bring the torch close to the piece you mean to weld.
Press (step 1) and release (step 2) the torch button.
The wire advances at closing speed until it comes into
contact with the material, at this point the arc is activated
and the speed goes back to the preset value.
Downloaded from
www.Manualslib.com
MIN MAX DEFAULT um
7
200
80
A
0,0
25,0
0,0
s
7
200
7
A
0,0
25,0
3,0
s
0,0
25,0
0,0
s
10
90
40
%
0,0
250
0,0
Hz
16
manuals search engine
Press the button (step 3) in order to start the welding
completion procedure.
Continue the gas supply until the torch button release (step
4) starting the POST GAS (adjustable).
The available procedures in the TIG modality are:
2T lift-arc welding:
Touch the piece being worked with the electrode of the
torch.
Press (1T) and keep the button for the torch held down.
Slowly lift the torch to strike the arc.
The WELDING CURRENT goes to the value set, carrying
out an ASCENT RAMP if necessary (adjustable time).
Release (2T) the button to start the process of completing
the weld.
The current goes to the FINAL CURRENT value set in a
NOTES
period equal to the DESCENT RAMP time (adjustable).
Main
The electric arc goes out.
parameter
The supply of gas continues for a period equal to the
Main
POST-GAS time (adjustable).
parameter
Main
4T lift-arc welding:
parameter
Main
Touch the piece being worked with the electrode of the
parameter
torch.
Secondary
Press (1T) and release (2T) the button of the torch.
parameter
Release the torch slowly to strike the arc.
accessible
from the sub-
The WELDING CURRENT goes to the value set, carrying
menu,
out an ASCENT RAMP if necessary (adjustable time).
visualized on
Press (3T) and keep the button held down to start the
D1 with S.UP.
process of completing the weld.
Secondary
parameter
The current goes to the FINAL CURRENT value set in a
accessible
period equal to the chosen DESCENT RAMP time
from the sub-
(adjustable).
menu,
The electric arc stays lit, and is supplied by a current equal
percentage of
the welding
to the FINAL CURRENT (adjustable). Under these
current,
conditions, it is possible to carry out the closing of the weld
visualized on
pool (CRATER FILLER CURRENT).
D1 with b.Cu.
Release (4T) the button to cut off the arc.
Secondary
parameter
The supply of gas continues for a period equal to the
accessible
POST-GAS time (adjustable).
from the sub-
S5: WELDING MODE selection key
menu,
The welding modes which can be selected are:
visualized on
D1 with FrE.
MIG/MAG CONTINUOUS
MMA
TIG CONTINUOUS/PULSED
The light lit up beside the symbol confirms the selection of
the process.
SOUND ALARM: a sound alarm has been provided to
protect the power generator: it blocks the primary inverter in
the event that the average welding current should exceed
260A for more than 1 second.
RESET PARAMETERS: to carry out a reset of the
parameters set on the front panel, and load the default
values, keep the S3 and S5 keys held down together during
the start-up of the machine.

Werbung