Herunterladen Diese Seite drucken

tau SPEED 2 Bedienungs- Und Wartungsanleitung Seite 17

Automatisierungen für schiebegatter

Werbung

220/230 V ac SINGLE PHASE PHASE MOTOR CONTROL CARD
LOGIC WITH MICROPROCESSOR
LED DISPLAY OF INPUT STATUS
LINE INPUT PROTECTION WITH FUSE
"PEDESTRIAN ENTRY " FUNCTION
BUILT -IN FLASHING CIRCUIT
"MAN PRESENT" CONTROL FUNCTION
RECEIVER CONNECTOR
TERMINAL BOARD CONNECTIONS
GB
1 - 2
5 -6.-7
3 - 4
8 - 9
10 - 11
12 - 14
13 - 14
14 - 15
16 - 20
17 - 20
18 - 20
19 - 20
23 -24
21 - 22
C
Downloaded from
www.Manualslib.com
K440M (FIG U) (SPEED 5 - 8)
220/230 V ac 50 Hz POWER SUPPLY input
MOTOR: 220/230 ac single phase output common =5 ;opening phase = 6 closing phase= 7; connect capacitor
between terminals 6-7 .
220/230 V ac 50 W max. FLASHING OUTPUT. The signal supplied is already modulated for direct use. Flashig
frequency is increased slightly in closing phase.
24 V ac 3 W output for GATE OPEN INDICATOR; the indicator lights up when the gate is completely open and
switches off when closing is started.
24 V ac 10 W output for POWER SUPPLY TO PHOTOCELLS, EXTERNAL RECEIVERS, etc.
OPEN LIMIT SWITCH input (Normally Closed contact) 14= Common.
CLOSE LIMIT SWITCH INPUT (Normally Closed contact). 14=Common
FIXED SAFETY EDGE input (Normally Closed Contact). Operates only during gate opening phase. The safety
edge shuts down gate movement temporarily and activates partial re-closure by approx. 20cm. to enable
removal of obstacles. (14=Common).
PHOTOCELLS or SAFETY DEVICE INPUT (Normally Closed contact); if this safety device trips, the gate is
shut down temporarily until the detected obstacle is removed (if dip switch nr.1 is set accordingly); during
closing the device shuts down gate movement followed by complete opening; (20=Common)
OPEN/CLOSE pushbutton input (Normally Open Contact): for relative operation, refere to function of dip
switches nr.1 and nr.2 (20=Common).
PEDESTRIAN pushbutton input (Normally Open contact); operation is the same as the OPEN/CLOSE
pushbutton but with a limited stroke of approx. 1 m. and set to regulate pedestrian traffic. (20=Common).
STOP pushbutton input (Normally Closed contact);when activated, the gate movement is stopped. The gate
opens automatically when reactivated (20=Common).
2nd. RADIO CHANNEL output (see J1 for alternative application).
AERIAL input: 21=central, 22=sheath
connector for radio card installation
manuals search engine
17

Werbung

loading

Diese Anleitung auch für:

Speed 5Speed 8