Operating Instructions SATAjet 1000 B (RP/HVLP)
• The following applications and operations lead to the loss
of the explosion protection and are, therefore, prohibited:
• Use of the spray gun in explosive areas belonging to ex-zone 0!
• Do not use solvents and cleaning agents based on halogenised
hydrocarbons! Chemical reaction which may occur when using these
substances may be explosive!
7.

Use

• Use only solvent-resistant, antistatic, undamaged and technically
flawless compressed air hoses with a permanent pressure resistance
of minimum 10 bar, e.g. Art. No. 53090!
The following requirements must be fulfilled:
• Compressed air connection 1/4" male thread or a suitable SATA con-
nection nipple.
• Ensure minimum compressed air volume (air consumption) and pres-
sure (recommended spray gun inlet pressure) according to chapter 2.
• Use clean compressed air, e.g. by installing the SATA filter 484, Art.
No. 92320
• Use an air hose with minimum 9 mm inner diameter (see warnings),
e.g. Art. No. 53090.
Before using the spray gun, heed / check the following points to warrant
safe working:
■ Screws [2-1], [2-2], [2-3], [2-4] and [2-5] fit firmly. Tighten screws if
necessary.
■ Fluid tip [2-2] tightened with a torque of 14 Nm [7-5].
■ Locking screw [10-1] tightened.
■ Technically clean compressed air is being used.
Warning! Risk of explosion!
Warning! Risk of explosion!