INSTALLATION MANUAL
Your new gas fireplace in general
This RAIS/ATTIKA product is a highly efficient convection gas fireplace with a sealed combustion
chamber for a balanced flue system. The fireplace has variable heating power and is equipped with a
burner which has been developed using the latest burner technology.
Before installation
All local laws and provisions should be studied before installation. Always check the national building
and gas regulations.
In addition, it should be confirmed that the information on the information plate relating to gas type
and gas pressure are in accordance with the local gas conditions that the fireplace shall be installed
under. The gas supply should be examined to ensure that it can supply the required amount of gas
and the required pressure.
It is recommended that gloves are worn when installing the gas fireplace to avoid fingerprints on
glass, etc.
Gas connection
This fireplace may only be installed, adjusted and serviced by an authorised and qualified heating
and plumbing/gas technician. The installation must comply with local and national building and gas
regulations, and the instructions in the installation manual must be followed. The installation manual
and user manual must be left with the customer, who must keep the manuals for later use. The manuals
are necessary when the fireplace is to be serviced.
The pipe on the gas hose has an external diameter of 8 mm or 10 mm, depending on the model.
When it has been determined where the fireplace shall be installed, a gas installation with a stopcock
in the vicinity of the fireplace must be executed to ensure that the gas supply and the fireplace can
be connected.
Since this fireplace is equipped with a sealed combustion chamber, a floor plate is not necessary.
If the fireplace is connected to bottled gas, it may only be connected to bottle gas that is equipped
with a gas regulator (low pressure regulator) that supplies the correct gas pressure.
Ensure that the balanced flue system is not blocked in any way and is free of vegetation in the form
of trees, bushes, etc.
The glass must always be cleaned on the outside before the fireplace is lit. Fingerprints must be wiped
off as these can burn into the glass.