Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 57
B R U G E R M A N U A L
B E D I E N U N G S A N L E I T U N G
U S E R M A N U A L
M A N U E L D ' U T I L I S AT E U R
B R U K E R V E I L E D N I N G
B R U K S A N V I S N I N G
V I S I O 2
V I S I O 3

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für attika V I S I O 2

  • Seite 1 B R U K E R V E I L E D N I N G B R U K S A N V I S N I N G V I S I O 2 V I S I O 3...
  • Seite 2 FR: BOIS Foyer à durèe de combustion limitèe, homologué pour cheminée à connexions multiples. Utiliser seulement les combustibles recommandés. Hergestellt für /Produced for: ATTIKA FEUER AG, Brunnmatt 16, CH-6330 Cham / RAIS A/S, Industrivej 20, DK-9900 Frederikshavn 15a B-VG VKF-NR: xxxxx...
  • Seite 3: Visio 3 Spareparts Drawing

    Visio 3 spareparts drawing VISIO 2 Reservedelstegning / Ersatzteilzeichnung / Spare parts drawing / Dessin des pièces de rechange / Reservdelsritning...
  • Seite 4 pareparts drawing VISIO 3 Reservedelstegning / Ersatzteilzeichnung / Spare parts drawing / Dessin des pièces de rechange / Reservdelsritning...
  • Seite 5 FYR MILJØVENLIGT! 5 Miljøvenlige råd til fornuftig fyring - sund fornuft for både miljø og pengepung. 1. Effektiv optænding. Brug små stykker træ (grantræ) og en egnet optændingsblok, f.eks. paraffinerede træfiberruller/ savsmuld. Åbn luftspjældet, så der tilføres rigeligt med luft, så...
  • Seite 6: Inhaltsverzeichnis

    Dansk RAIS/ - Brugermanual til VISIO VISIO 2 - VISIO 3 Revision : Dato 27. marts 2015 InDleDnIng ..........................4 gaRantI ............................ 5 SpecIfIkatIOneR ........................6 afStanDe/mål .......................... 7 kOnVektIOn ........................... 11 Valg af mateRIale tIl InDbygnIng ..................12 SkORSten ..........................
  • Seite 7: Dato

    Dansk RAIS/ - Brugermanual til VISIO Indledning attika tillykke med Deres nye RaIS/ brændeovn. attika en RaIS/ brændeovn er mere end blot en varmekilde, den er også udtryk for, at De lægger vægt på design og høj kvalitet i Deres hjem.
  • Seite 8: Garanti

    Dansk RAIS/ - Brugermanual til VISIO garanti attika RaIS/ brændeovne kontrolleres i flere omgange i forhold til sikkerhed, samt kvaliteten af materialer og forarbejdning. Vi yder garanti på alle modeller, og garantiperi- oden starter på installationsdatoen. garantien dækker: • dokumenterede funktionsfejl på grund af fejlagtig forarbejdning •...
  • Seite 9: Specifikationer

    Dansk RAIS/ - Brugermanual til VISIO attika RaIS/ VISIO er indsatsovne med hæve/sænke låge. VISIO 2 har frontglas og sideglas til enten til højre eller venstre. VISIO 3 har frontglas og 2 sideglas. Specifikationer DtI ref.: 300-elab-2080-en / 300-elab-2080-nS...
  • Seite 10: Afstande/Mål

    Dansk RAIS/ - Brugermanual til VISIO afstande/mål afstand fra gulv til center røgafgang top afstand fra gulv til center røgafgang bag afstand fra bagside til luftindtag i bunden (air-System) n: afstand fra side til luftindtag i bunden (air-System) VISIO 2 med topafgang bemærk at røgstuds kan dreje trinløst.
  • Seite 11 Dansk RAIS/ - Brugermanual til VISIO VISIO 2 med bagafgang bemærk at røgstuds kan dreje trinløst. Røg til ba...
  • Seite 12 Dansk RAIS/ - Brugermanual til VISIO VISIO 3 med topafgang bemærk at røgstuds kan dreje trinløst. 218 - 280 - 480  29,5 39,5 29,5...
  • Seite 13 Dansk RAIS/ - Brugermanual til VISIO VISIO 3 med bagafgang bemærk at røgstuds kan dreje trinløst.
  • Seite 14: Konvektion

    Dansk RAIS/ - Brugermanual til VISIO konvektion attika RaIS/ ovne er konvektionsovne. konvektion betyder, at der opstår luftcirkulation, således at varmen fordeles mere jævnt i hele rummet. kolde luft trækkes ind ved ovnens bund, og løber op langs ovnens brændkammer, hvorved luften opvarmes.
  • Seite 15: Valg Af Materiale Til Indbygning

    Dansk RAIS/ - Brugermanual til VISIO Valg af materiale til indbygning Som ubrændbart materiale vælges paneler/mursten med en isolansværdi større end 0,03 xk/W.Isolans defineres som vægtykkelse (i m) divideret med væggens lambda værdi. Rådfør dig med installatøren/skorstensfejeren. under testen blev ovnen installeret i et kabinet lavet af ikke-brændbare bygningsplader (12,5 mm feRmacell h2O powerboard).
  • Seite 16: Installation

    Dansk RAIS/ - Brugermanual til VISIO Installation Det er vigtigt at ovnen bliver installeret korrekt af hensyn til både miljø og sikkerhed. Ved installation af ovnen skal alle lokale regler og forordninger, inklusive dem der henviser til nationale og europæiske standarder, overholdes. lokale myndigheder samt skorstens- fejermester bør kontaktes før opstilling.
  • Seite 17: Montering Af Reflektorplade - Visio 2

    Dansk RAIS/ - Brugermanual til VISIO montering af reflektorplade - VISIO 2 Ovnen er udstyret med en afmonter reflektorpladen og vend den reflektorplade på bagsiden. på hovedet. monter pladen med de samme skruer (som vist). montering af reflektorplade - VISIO 3...
  • Seite 18: Transportsikring - Visio 2 - Visio 3

    Dansk RAIS/ - Brugermanual til VISIO buk de 2 udskæringer som vist og monter pladen ovenpå ovnen. transportsikring - VISIO 2 - VISIO 3 Inden ovnen installeres fjernes transportsikringen: • på VISIO 2 er der 1 skrue på siden...
  • Seite 19: Visio 2 - Indbygning Af Indsatsovn

    Dansk RAIS/ - Brugermanual til VISIO sol 50mm Hulmål til VISIO 2 - Fermacell 13 VISIO 2 - Indbygning af indsatsovn ning af Indvendige mål er angivet ved indbygning af Indbygningsmål til VISIO 2 - 12,5 mm fermacell med 25 mm brandbats ovn (uden afdækning).
  • Seite 20 Hulmål til VISIO 2 - Super Isol 50mm attika Dansk RAIS/ - Brugermanual til VISIO Indvendige mål er angivet ved indbygning af Indbygningsmål til VISIO 2 - kalciumsilikat paneler (f.eks. 50 mm Super Isol eller Skamotec 225) ovn (uden afdækning).
  • Seite 21 Mål er angivet ved indbygning af ovn uden afdækning. attika Dansk RAIS/ - Brugermanual til VISIO bemæRk! Ved indbygning uden frontafdækning (tilbehør) anbefaler RaIS at der er en luftspalte på 5 mm mellem paneler og toppen af ovnen (se skitse forneden).
  • Seite 22 Dansk RAIS/ - Brugermanual til VISIO Indbygningsmål til Visio 2 - Mursten (124900 Indbygningsmål til VISIO 2 - mursten Indvendige mål er angivet ved indbygning af ovn (uden afdækn hulmål (højde x bredde x dybde) min. 432 x 685 x 490 mm (indv. mål).
  • Seite 23 Opstillings afstand til Visio 2 - Murst attika Dansk RAIS/ - Brugermanual til VISIO Luftgab (indv) I siden og bunden af ovn. bemæRk! Ved indbygning uden frontafdækning (tilbehør) anbefaler RaIS at der er en luftspalte på 5 Mål er angivet ved indbygning af ovn uden afdækn mm mellem paneler og toppen af ovnen (se skitse forneden).
  • Seite 24: Visio 2 - Opstillingsafstande

    Dansk RAIS/ - Brugermanual til VISIO VISIO 2 - opstillingsafstande paneler - VISIO 2 paneltyper: • 12,5 mm fermacell med 25 mm brandbats • 50 mm kalciumsilikat paneler Der skal indbygges konvektionshuller over og under ovnen. Opbygning af bagvæg, sidevæg og skråplade...
  • Seite 25 Dansk RAIS/ - Brugermanual til VISIO VISIO 2 - opstillingsafstande - paneler afstand fra sideglas til brændbart min. 350 mm (f.eks. dørkarm) min. 130 mm møbleringsafstand fra sideglas min. 850 mm afstand til brændbart fra frontglas min. 300 mm alternativ ubrændbar væg...
  • Seite 26 Dansk RAIS/ - Brugermanual til VISIO VISIO 2 - opstillingsafstande - paneler ObS! Isoleret skorsten (medfølger ikke) helt ned til røgstuds frihøjde over brandkammer min. 698 mm. konvektionshuller placeres lige under skråpladen. for at guide den varme luft ud af konvektionsristene, skal Reflektorplade der monteres en skrå...
  • Seite 27 Dansk RAIS/ - Brugermanual til VISIO mursten - VISIO 2 hvis der indbygges konvektionshuller over og under ovnen, kan afstande til brændbart overføres fra panelopstillingen til VISIO 2. hvis der ikke skabes tilstrækkelig konvektion, kan der forekomme skader på murstens- vægge.
  • Seite 28 Dansk RAIS/ - Brugermanual til VISIO VISIO 2 - opstillingsafstande- mursten afstand fra sideglas til brændbart min. 350 mm (f.eks. dørkarm) - gælder kun med konvektions- huller over/under ovnen. møbleringsafstand fra min. 130 mm sideglas min. 850 mm afstand til brændbart fra frontglas min.
  • Seite 29 Dansk RAIS/ - Brugermanual til VISIO VISIO 2 - opstillingsafstande- mursten frihøjde over brandkammer min. 698 mm eventuelle konvektionshuller placeres lige under skråpladen. Reflektorplade for at guide den varme luft ud af konvektionsristene, skal der monteres en skrå og ikke brændbar isolerende plade...
  • Seite 30: Visio 3 - Indbygning Af Indsatsovn

    Dansk RAIS/ - Brugermanual til VISIO VISIO 3 - Indbygning af indsatsovn Indbygningsmål til VISIO 3 - paneler hulmål (højde x bredde x dybde) min. 432 x 770 x 443 mm (indv. mål). Hulmål til VISIO 3 - Fermacell 13...
  • Seite 31 Dansk RAIS/ - Brugermanual til VISIO Indbygningsmål til Visio 2 - Mursten (1249006) Indbygningsmål til VISIO 3 - mursten Indvendige mål er angivet ved indbygning af ovn (uden afdækning) Hvis en afdækning indbygges, skal hulmålet øges hulmål (højde x bredde x dybde) min. 432 x 770 x 443 mm (indv. mål).
  • Seite 32: Visio 3 - Opstillingsafstande

    Dansk RAIS/ - Brugermanual til VISIO VISIO 3 - opstillingsafstande paneler - VISIO 3 paneltyper: • 12,5 mm fermacell med 25 mm brandbats • 50 mm kalciumsilikat paneler Der skal indbygges konvektionshuller over og under ovnen. Opbygning af bagvæg og skråplade...
  • Seite 33 Dansk RAIS/ - Brugermanual til VISIO VISIO 3 - opstillingsafstande - paneler afstand fra sideglas til brændbart afstand fra sideglas til brændbart min. 220 mm (f.eks. dørkarm) min. 220 mm (f.eks. dørkarm) møbleringsafstand fra møbleringsafstand fra sideglas min. 750 mm sideglas min.
  • Seite 34 Dansk RAIS/ - Brugermanual til VISIO VISIO 3 - opstillingsafstande - paneler ObS! Isoleret skorsten (medfølger ikke) helt ned til røgafgangsadapter frihøjde over brandkammer min. 698 mm konvektionshuller placeres lige under skråpladen. for at guide den varme luft ud af konvektionsristene, skal Reflektorplade der monteres en skrå...
  • Seite 35 Dansk RAIS/ - Brugermanual til VISIO mursten - VISIO 3 hvis der indbygges konvektionshuller over og under ovnen, kan afstande til brændbart overføres fra panelopstillingen til VISIO 3. hvis der ikke skabes tilstrækkelig konvektion, kan der forekomme skader på murstens- vægge.
  • Seite 36 Dansk RAIS/ - Brugermanual til VISIO VISIO 3 - opstillingsafstande- mursten afstand fra sideglas til brændbart afstand fra sideglas til brændbart min. 220 mm (f.eks. dørkarm) min. 220 mm (f.eks. dørkarm) - gælder kun med konvektions- - gælder kun med konvektions- huller over/under ovnen.
  • Seite 37 Dansk RAIS/ - Brugermanual til VISIO VISIO 3 - opstillingsafstande- mursten frihøjde over brandkammer min. 698 mm eventuelle konvektionshuller placeres lige under skråpladen. for at guide den varme luft ud af konvektionsristene, skal der monteres en skrå og ikke Reflektorplade brændbar isolerende plade...
  • Seite 38: Air-System

    Dansk RAIS/ - Brugermanual til VISIO air-system Ved montage af air-system sikres det, at luftreguleringssystemet får frisk luft udefra. for at sikre at air-systemet fungerer, skal man byggemæssigt sørge for, at der ikke kan opstå undertryk i boligen. hvis der er installeret konvektionsriste, må de ikke blokeres.
  • Seite 39: Brændsel

    Dansk RAIS/ - Brugermanual til VISIO brændsel Ovnen er testet iht. DS/en 13229:2001, DS/en 13229:2001/a1:2003, DS/en 13229:2001/ a2:2004 og nS 3058/3059 til forbrænding af kløvet, tørt birk, og godkendt til løvtræ/ nåletræ. brændet skal have et vandindhold på 15-20% og en max. længde på ca. 30 cm.
  • Seite 40: Tørring Og Lagring

    • Det er en god idè at tage brænde ind 2-3 dage før det skal bruges. Regulering af forbrændingsluft alle RaIS/attika ovne er forsynet med ét-grebs betjeningshåndtag til regulering af spjældet. Ovnens individuelle regulering kan ses på illustrationerne (næste afsnit).
  • Seite 41: Ventilation

    Dansk RAIS/ - Brugermanual til VISIO Ventilation Der må ikke være et udsugningsanlæg/emhætte (køkken) i samme rum som ovnen, da dette kan medføre at ovnen afgiver røggasser ind i lokalet. Ovnen har behov for permanent og tilstrækkelig med luft for at kunne fungere sikkert og effektivt.
  • Seite 42: Førstegangsoptænding

    Dansk RAIS/ - Brugermanual til VISIO førstegangsoptænding en forsigtig start betaler sig. begynd med et lille bål, så brændeovnen kan tilvænnes den høje temperatur. Dette giver den bedste start og eventuelle skader undgås. Vær opmærksom på, at der kan fremkomme en ejendommelig, men ufarlig lugt og røgudvikling fra ovnens overflade under den første optænding.
  • Seite 43 Dansk RAIS/ - Brugermanual til VISIO • bålet tændes. • Sæt spjældet i pos. 3 (i ca. 15 min.), derefter i pos. 2. • luk lågen helt og løft i lågehåndtaget (luftgab på 1-2 cm). • når ilden har godt fat i optændingspindene lukkes lågen helt (efter ca.
  • Seite 44: Kontrol

    Dansk RAIS/ - Brugermanual til VISIO • hvis det er nødvendigt sæt spjældhåndtaget i position 3 (helt til højre) i 2-5 min for at få ‘gang’ i ilden. • Derefter sættes spjældet mellem pos. 1 og pos. 2 ( se ‘Indstilling af spjæld’).
  • Seite 45 Advarsel Advarsel Advarsel attika Dansk RAIS/ - Brugermanual til VISIO Hvis brændet kun ulmer eller ryger, og der tilføres for lidt luft, udvikles der Hvis brændet kun ulmer eller ryger, og der tilføres for lidt luft, udvikles der Hvis brændet kun ulmer eller ryger, og der tilføres for lidt luft, udvikles der Advarsel!! uforbrændte røggasser.
  • Seite 46: Rengøring Og Pleje

    Dansk RAIS/ - Brugermanual til VISIO Rengøring og pleje brændeovn og skorsten skal tilses af en skorstensfejer 1 gang om året. Ved rengøring og pleje skal ovnen være kold. er glasset tilsodet: • Rengør glasset regelmæssigt og kun når ovnen er kold, ellers brænder soden sig fast.
  • Seite 47: Rengøring Af Lågeglas - Visio 2

    Dansk RAIS/ - Brugermanual til VISIO Rengøring af lågeglas - VISIO 2 lågen låses inden den rengøres. med specialnøglen (leveret med ovn) vrides låsen (2 stk.) over glasset ud af. frontglasset frigøres ved at vride beslaget over og under glasset ud af.
  • Seite 48: Rengøring Af Lågeglas - Visio 3

    Dansk RAIS/ - Brugermanual til VISIO Rengøring af lågeglas - VISIO 3 lågen låses inden den rengøres. med specialnøglen (leveret med ovn) vrides låsen (1 stk. i hver side) over glasset ud af. Sideglasset frigøres ved at vride beslaget over og under glasset ud af.
  • Seite 49: Rengøring Af Brændkammer

    Dansk RAIS/ - Brugermanual til VISIO Rengøring af brændkammer asken skrabes/skovles ned i risten i midten af ovnen. askebakken under ovnen kan tages ud og tømmes i ikke brændbar beholder indtil den er afkølet. bortskaffelse af aske sker ved almindelig dagrenovation.
  • Seite 50: Driftsforstyrrelser

    Dansk RAIS/ - Brugermanual til VISIO Røgchikanen hviler på 2 kanaler; skub den fremad, tilt og sænk den og fjernes derefter. stift stift fjern skidt og støv, og sæt delene når chikanen monteres, fastgøres på plads i omvendt rækkefølge.
  • Seite 51 Dansk RAIS/ - Brugermanual til VISIO Ovn brænder for stærkt kan skyldes • utæthed ved lågepakning • for stort skorstenstræk >22 pa, reguleringsspjæld bør monteres. Ovn brænder for svagt kan skyldes • for lidt brænde • for lidt lufttilførsel til rumventilation •...
  • Seite 52: Tilbehør Visio 2 - Visio 3

    Dansk RAIS/ - Brugermanual til VISIO tilbehør VISIO 2 - VISIO 3 frontafdækning til VISIO 2 frontafdækning til VISIO 2 6 sidet - venstre - 6 mm tyk 6 sidet - højre - 6 mm tyk 124142080 - rustfri...
  • Seite 53 Dansk RAIS/ - Brugermanual til VISIO konvektionsrist - front konvektionsrist - side 511480470 - hvid 836480470 - hvid 511480490 - sort 836480490 - sort 511480870 - hvid 836480870 - hvid 511480890 - sort 836480890 - sort 836480470 511480470 836480490...
  • Seite 54: Reservedele Visio 2

    Dansk RAIS/ - Brugermanual til VISIO Reservedele VISIO 2 pos. antal Varenr. beskrivelse håndtag for spjæld - komplet 1240905mon Spjæld - komplet 1240990 lågehåndtag 1241015mon kold håndtag - komplet 1242410 glaslister - malet til VISIO 2l (venstre) 124205090 glaslister - rustfri til Visio 2l (venstre) 124205080 glaslister - malet til VISIO 2R (højre)
  • Seite 55: Prøvningsattest (Danmark)

    Dansk RAIS/ - Brugermanual til VISIO pRøVnIngSatteSt (DanmaRk)                   TEST Reg.nr. 300 ...
  • Seite 57: Recycling

    HEIZEN SIE UMWELTFREUNDLICH! 5 umweltfreundliche Empfehlungen zum vernünftigen Heizen – gesunde Vernunft sowohl für die Umwelt als auch für das Portemonnaie. 1. Effektives Anzünden. Verwenden Sie kleine Holzscheite (ideal: Tannenholz) und eine geeignete Anzündhilfe, z.B. parafinge- tränkte Holzfaserröllchen. Öffnen Sie die Luftklappe, so daß reichlich Luft zugeführt wird, damit die Gase des erwärmten Holzes schnell abbrennen.
  • Seite 58 Deutsch RAIS/ - Anleitung für VISIO VISIO 2 - VISIO 3 Revision : Datum : 27. märts 2015 eInleItung ..........................56 gaRantIe ..........................57 SpezIfIkatIOnen ........................58 abStänDe ..........................59 kOnVektIOn ......................... 63 Wahl DeS mateRIalS füR Den eInbau ................64 SchORnSteIn ........................
  • Seite 59: Datum

    Deutsch RAIS/ - Anleitung für VISIO einleitung attika herzlichen glückwunsch zu Ihrem neuen RaIS/ - kaminofen. attika ein RaIS/ - kaminofen ist mehr als nur eine Wärmequelle; er ist auch ausdruck dafür, dass Sie in Ihrem heim auf Design und hohe Qualität Wert legen.
  • Seite 60: Garantie

    Schaden behoben wird. Im falle einer Reparatur sor- gen wir für eine fachgerechte ausführung. garantie-ansprüche auf nachgelieferte oder durch uns reparierte teile werden nach natio- nalem bzw. nach eu-Recht gehandhabt. Die jeweils gültigen garantiebestimmungen können bei der attika feuer ag angefordert werden.
  • Seite 61: Spezifikationen

    Deutsch RAIS/ - Anleitung für VISIO attika RaIS/ VISIO sind einsatzöfen mit hub- und Senktür. VISIO 2 hat ein frontglas und ein Seitenglas entweder rechts oder links. VISIO 3 hat ein frontglas und 2 Seitengläser. Spezifikationen DtI Ref.: 300-elab-2080-en / 300-elab-2080-nS...
  • Seite 62: Abstände

    Deutsch RAIS/ - Anleitung für VISIO abstände I: abstand vom fußboden zur oberen montage des Rauchrohres am Ofen. j: abstand vom fußboden zur mitte des Rauchrohres (hinten). k: abstand von der Rückseite zum frischlufteinlass an der unterseite (luftsystem). n: abstand von der Ofenseite zum frischlufteinlass an der unterseite (luftsystem) VISIO 2 mit oberem ausgang beachten Sie, dass der Rauchrohrstutzen kontinuierlich drehen kann.
  • Seite 63 Deutsch RAIS/ - Anleitung für VISIO VISIO 2 mit rückwärtigen ausgang beachten Sie, dass der Rauchrohrstutzen kontinuierlich drehen kann. Røg til ba...
  • Seite 64 Deutsch RAIS/ - Anleitung für VISIO VISIO 3 mit oberem ausgang beachten Sie, dass der Rauchrohrstutzen kontinuierlich drehen kann. 218 - 280 - 480  29,5 39,5 29,5...
  • Seite 65 Deutsch RAIS/ - Anleitung für VISIO VISIO 3 mit rückwärtigen ausgang beachten Sie, dass der Rauchrohrstutzen kontinuierlich drehen kann.
  • Seite 66: Konvektion

    Deutsch RAIS/ - Anleitung für VISIO konvektion attika RaIS/ - kaminöfen sind konvektionsöfen. Das bewirkt, dass die außenpaneele des Ofens nicht übermäßig aufgeheizt werden. konvektion bedeutet, dass eine luftzirkulation entsteht, so dass die Wärme gleichmäßiger im ganzen Raum verteilt wird.
  • Seite 67: Wahl Des Materials Für Den Einbau

    Deutsch RAIS/ - Anleitung für VISIO Wahl des materials für den einbau als nicht brennbares material sind paneele/mauersteine mit einem Isolierwert über 0,03 m²xk/W zu wählen. Der Isolierwert wird als Wandstärke (in m) dividiert durch den lamb- dawert der Wand definiert. lassen Sie sich vom Installateur/Schornsteinfeger beraten.
  • Seite 68: Installation

    Deutsch RAIS/ - Anleitung für VISIO Installation Der Ofen muss unter berücksichtigung aller geltenden lokalen Regeln und Vorschriften, einschließlich diejenigen, die sich auf nationalen und europäischen normen beziehen, auf- gestellt und installiert werden. lokale behörden sowie der Schornsteinfegermeister sind vor dem aufstellen zu kontaktieren.
  • Seite 69: Montage Der Reflektorplatte - Visio 2

    Deutsch RAIS/ - Anleitung für VISIO montage der Reflektorplatte - VISIO 2 Der Ofen ist auf der Rückseite mit montieren Sie die Reflektorplatte ab und drehen einer Reflektorplatte ausgerüstet. Sie sie auf den kopf. montieren Sie die platte mit denselben Schrauben (wie abgebildet).
  • Seite 70: Transportsicherung - Visio 2 - Visio 3

    Deutsch RAIS/ - Anleitung für VISIO biegen Sie die 2 aussparungen wie abgebildet und montieren Sie die platte auf dem Ofen. transportsicherung - VISIO 2 - VISIO 3 Vor der Installation des Ofens ist die transportsicherung zu entfernen: • am VISIO 2 befindet sich 1 Schraube an der Seite...
  • Seite 71: Visio 2 - Einbau Des Einsatzofens

    Deutsch RAIS/ - Anleitung für VISIO VISIO 2 - einbau des einsatzofens Isol 50mm Hulmål til VISIO 2 - Fermacell 13 einbaumaße für VISIO 2 – 12,5 mm fermacell mit 25 mm brandschutz- gning af Indvendige mål er angivet ved indbygning af matte ovn (uden afdækning).
  • Seite 72 Deutsch RAIS/ - Anleitung für VISIO Hulmål til VISIO 2 - Super Isol 50mm einbaumaße für VISIO 2 – Isolierungsplatten aus calciumsilikat Indvendige mål er angivet ved indbygning af (z.b. 50 mm Super Isol oder Skamotec 225) ovn (uden afdækning).
  • Seite 73 Luftgab (indv.) i toppen af ovn attika Deutsch RAIS/ - Anleitung für VISIO Mål er angivet ved indbygning af ovn uden afdækning. bItte beachten! attika beim einbau ohne frontabdeckung (zubehör) empfiehlt RaIS/ , dass sich zwischen paneelen und der Oberseite des Ofens ein luftspalt von 5 mm befindet (siehe folgende Skizze).
  • Seite 74 Deutsch RAIS/ - Anleitung für VISIO Indbygningsmål til Visio 2 - Mursten (124900 einbaumaße für VISIO 2 – mauerstein Indvendige mål er angivet ved indbygning af ovn (uden afdækn hohlmaß (höhe x breite x tiefe) mind. 432 x 685 x 490 mm (Innenmaß).
  • Seite 75 Opstillings afstand til Visio 2 - Murst attika Deutsch RAIS/ - Anleitung für VISIO Luftgab (indv) I siden og bunden af ovn. bItte beachten! attika beim einbau ohne frontabdeckung (zubehör) empfiehlt RaIS/ , dass sich zwischen Mål er angivet ved indbygning af ovn uden afdækn paneelen und der Oberseite des Ofens ein luftspalt von 5 mm befindet (siehe folgende Skizze).
  • Seite 76: Visio 2 - Aufstellungsabstände

    Deutsch RAIS/ - Anleitung für VISIO VISIO 2 - aufstellungsabstände paneele - VISIO 2 paneeltypen: • 12,5 mm fermacell mit 25 mm brandschutzmatte • 50 mm calciumsilikatplatte über und unter dem Ofen sind konvektionslöcher einzubauen. aufbau von Schrägplatte, Rück- und Seitenwand...
  • Seite 77 Deutsch RAIS/ - Anleitung für VISIO VISIO 2 - aufstellungsabstände - paneele abstand vom Seitenglas zu brennbaren Stoffen mind. 350 mm (z. b. türrahmen) mind. 130 mm möbelabstand vom Seitenglas mind. 850 mm abstand vom frontglas zu brennbaren Stoffen mind. 300 mm...
  • Seite 78 Deutsch RAIS/ - Anleitung für VISIO VISIO 2 - aufstellungsabstände - paneele bItte beachten! Isolierter Schornstein (nicht im lieferumfang) bis hinab zum Rauchrohrstutzen lichte höhe über feuerraum mind. 698 mm. konvektionslöcher sind direkt unter der Schrägplatte zu platzieren Reflektor...
  • Seite 79 Deutsch RAIS/ - Anleitung für VISIO mauerstein - VISIO 2 Wenn konvektionslöcher über und unter dem Ofen eingebaut werden, können die ab- stände zu brennbarem material von der paneelaufstellung (VISIO 2) übernommen werden. Wenn nicht ausreichend konvektion erzeugt wird, kann es zu Schäden an den mauer- steinwänden führen.
  • Seite 80 Deutsch RAIS/ - Anleitung für VISIO VISIO 2 - aufstellungsabstände - mauerstein abstand vom Seitenglas zu brennbaren Stoffen mind. 350 mm (z.b. türrahmen); der abstand gilt nur für konvektionslöcher über/unter dem Ofen. möbelabstand vom mind. 130 mm Seitenglas mind. 850 mm abstand vom frontglas zu brennbaren Stoffen mind.
  • Seite 81 Deutsch RAIS/ - Anleitung für VISIO VISIO 2 - aufstellungsabstände - mauerstein lichte höhe über feuerraum mind. 698 mm eventuelle konvektionslöcher sind direkt unter der Schräg- platte zu platzieren. Reflektorplatte um die warme luft aus den konvektionsrosten zu leiten, muss eine schräge und nicht...
  • Seite 82: Visio 3 - Einbau Des Einsatzofens

    Deutsch RAIS/ - Anleitung für VISIO VISIO 3 - einbau des einsatzofens einbaumaße für VISIO 3 - paneele hohlmaß (höhe x breite x tiefe) mind. 432 x 770 x 443 mm (Innenmaß). Hulmål til VISIO 3 - Fermacell 13...
  • Seite 83 Deutsch RAIS/ - Anleitung für VISIO Indbygningsmål til Visio 2 - Mursten (1249006) einbaumaße für VISIO 3 - mauerstein Indvendige mål er angivet ved indbygning af ovn (uden afdækning) Hvis en afdækning indbygges, skal hulmålet øges hohlmaß (höhe x breite x tiefe) mind. 432 x 770 x 443 mm (Innenmaß).
  • Seite 84: Visio 3 - Aufstellungsabstände

    Deutsch RAIS/ - Anleitung für VISIO VISIO 3 - aufstellungsabstände paneele - VISIO 3 paneeltypen: • 12,5 mm fermacell mit 25 mm brandschutzmatte • 50 mm calciumsilikatplatte über und unter dem Ofen sind konvektionslöcher einzubauen. aufbau von Schrägplatte und Rückwand...
  • Seite 85 Deutsch RAIS/ - Anleitung für VISIO VISIO 3 - aufstellungsabstände - paneele abstand vom Seitenglas abstand vom Seitenglas zu brennbaren Stoffen zu brennbaren Stoffen mind. 220 mm (z.b. türrahmen) mind. 220 mm (z.b. türrahmen) möbelabstand vom möbelabstand vom Seitenglas mind. 750 mm Seitenglas mind.
  • Seite 86 Deutsch RAIS/ - Anleitung für VISIO VISIO 3 - aufstellungsabstände - paneele bItte beachten! Isolierter Schornstein (nicht im lieferumfang) bis hinab zum Rauchrohrstutzen lichte höhe über feuerraum mind. 698 mm konvektionslöcher sind direkt unter der Schrägplatte zu platzieren um die warme luft aus den...
  • Seite 87 Deutsch RAIS/ - Anleitung für VISIO mauerstein - VISIO 3 Wenn konvektionslöcher über und unter dem Ofen eingebaut werden, können die ab- stände zu brennbarem material von der paneelaufstellung (VISIO 3) übernommen werden. Wenn nicht ausreichend konvektion erzeugt wird, kann es zu Schäden an den mauer- steinwänden führen.
  • Seite 88 Deutsch RAIS/ - Anleitung für VISIO VISIO 3 - aufstellungsabstände - backstein abstand vom Seitenglas zu abstand vom Seitenglas zu brennbaren Stoffen mind. 220 mm brennbaren Stoffen mind. 220 mm (z.b. türrahmen); der abstand gilt (z.b. türrahmen); der abstand gilt nur für konvektionslöcher...
  • Seite 89 Deutsch RAIS/ - Anleitung für VISIO VISIO 3 - aufstellungsabstände - mauerstein lichte höhe über feuerraum mind. 698 mm eventuelle konvektionslöcher sind direkt unter der Schräg- platte zu platzieren um die warme luft aus den konvektionsrosten zu leiten, muss eine schräge und nicht...
  • Seite 90: Luftsystem

    Deutsch RAIS/ - Anleitung für VISIO luftsystem bei der montage des luftsystems wird gewährleistet, dass das luftregulierungssystem frischluft von außen erhält. um die funktion des luftsystems zu gewährleisten, muss man hinsichtlich des gebäudes dafür sorgen, dass in der Wohnung kein unterdruck entstehen kann.
  • Seite 91: Verwenden Sie Nur Empfohlenes Feuerholz

    Deutsch RAIS/ - Anleitung für VISIO feuerholz Die öfen wurde nach en13240:2001, en13240:2001/a2:2004, cen/tS 15883 und nS 3058/3059 für die Verbrennung von gespaltener, trockener birke geprüft, und ist für laub- und nadelhölzer zugelassen. Das brennholz darf eine maximale Restfeuchtigkeit von 15-20 % und eine maximale länge von 30 cm aufweisen.
  • Seite 92: Trocknung Und Lagerung

    Deutsch RAIS/ - Anleitung für VISIO trocknung und lagerung holz benötigt zeit zum trocknen. eine korrekte lufttrocknung braucht etwa zwei jahre. hier folgen ein paar tipps: • bewahren Sie holz gesägt, gespalten und gestapelt an einem luftigen, sonnen- reichen und vor Regen geschützten Ort auf (die Südseite des hauses ist besonders gut geeignet).
  • Seite 93: Lüftung

    Deutsch RAIS/ - Anleitung für VISIO lüftung beachten Sie, dass ein eventuelles mechanisches absaugen wie beispielsweise über eine Dunstabzugshaube (küche) die luftzufuhr verringern kann. Dies kan dazu führen dass der Ofen Rauch und Qualm in den Raum abgibt. um eine gute Verbrennung zu gewährleisten, muss im aufstellungsraum für eine reichli- che frischluftzufuhr gesorgt werden (siehe abschnit luftsystem).
  • Seite 94: Erstes Anzünden

    Deutsch RAIS/ - Anleitung für VISIO erstes anzünden ein vorsichtiger Start zahlt sich aus. beginnen Sie mit einem kleinen feuer, so dass sich der kaminofen an die hohe temperatur gewöhnen kann. Das sorgt für den besten Start und eventuelle Schäden werden vermieden.
  • Seite 95 Deutsch RAIS/ - Anleitung für VISIO • zünden Sie das feuer an. • Stellen Sie den bedienhebel in pos. 3 (für ca. 15 min.), danach in pos. 2. • Schließen Sie die tür und heben Sie es bis ein Spalt von 1-2cm offen steht.
  • Seite 96: Kontrolle

    Deutsch RAIS/ - Anleitung für VISIO • bei bedarf stellen Sie den bedienhebel für 2 bis 5 min. in position 3 (ganz nach rechts), um das feuer „in gang“ zu bekommen. • Danach ist der bedienhebel zwischen pos. 1 und pos. 2 zu stellen (siehe „einstellung der luftklappe“).
  • Seite 97 Advarsel Advarsel Advarsel attika Deutsch RAIS/ - Anleitung für VISIO Hvis brændet kun ulmer eller ryger, og der tilføres for lidt luft, udvikles der Hvis brændet kun ulmer eller ryger, og der tilføres for lidt luft, udvikles der Hvis brændet kun ulmer eller ryger, og der tilføres for lidt luft, udvikles der Warnung!! uforbrændte røggasser.
  • Seite 98: Reinigung Und Pflege

    Wir em- pfehlen ausschliesslich den von uns angebotenen Schmierspray, da es bei der Verwendung anderer produkte zu geruchsbildung und Rückständen kommen kann. Den Schmierspray können Sie bei Ihrem attika-/RaIS-fachhändler beziehen.
  • Seite 99: Reinigung Der Türgläser - Visio 2

    Deutsch RAIS/ - Anleitung für VISIO Reinigung der türgläser - VISIO 2 Verriegeln Sie die tür vor dem Reinigen. ziehen Sie mit dem Spezialschlüssel (im lieferumfang enthalten) das Schloss (2 Stück) über dem glas nach außen. Das frontglas wird durch ziehen des beschlages über und unter dem glas nach außen freigelegt.
  • Seite 100: Reinigung Der Türgläser - Visio 3

    Deutsch RAIS/ - Anleitung für VISIO Reinigung der türgläser - VISIO 3 Verriegeln Sie die tür vor dem Reinigen. ziehen Sie mit dem Spezialschlüssel (im lieferumfang enthalten) das Schloss (1 Stück auf jedr Seite) über dem glas nach außen.
  • Seite 101: Reinigung Der Brennkammer

    Deutsch RAIS/ - Anleitung für VISIO Reinigung der brennkammer Schaben/schaufeln Sie die asche in den Rost in der mitte des feuerraums. nehmen Sie die ascheschublade aus dem Ofen und entleeren Sie die asche in einem nicht brennbaren behälter, bis sie abgekühlt ist. Die entsorgung erfolgt über die normale müllabfuhr.
  • Seite 102: Betriebsstörungen

    Deutsch RAIS/ - Anleitung für VISIO Die Rauchschikane ruht auf 2 kanälen; schieben Sie sie nach vorn, kippen und senken Sie sie und nehmen sie danach hinaus. Stift Stift Wenn die Schikane montiert wird, wird die entfernen Sie Schmutz und Staub und platte unter der Verriegelungsplatte befestigt.
  • Seite 103: Verringerter Zug Im Schornstein

    Deutsch RAIS/ - Anleitung für VISIO Der Ofen brennt zu kräftig kann verursacht werden durch • undichtigkeit an der feuerraumtürdichtung. • zu großen zug im Schornstein (>22 pa); Drosselklappe sollte montiert werden. Der Ofen brennt zu schwach kann verursacht werden durch •...
  • Seite 104: Zubehör Visio 2 - Visio 3

    Deutsch RAIS/ - Anleitung für VISIO zubehör VISIO 2 - VISIO 3 frontabdeckung - VISIO 2 frontabdeckung - VISIO 2 6-seitig - links - 6 mm Dicke 6-seitig - rechts - 6 mm Dicke 124142080 - rostfrei 124143080 - rostfrei...
  • Seite 105 Deutsch RAIS/ - Anleitung für VISIO konvektionsrost – front konvektionsrost – Seite 511480470 - weiß 836480470 - weiß 511480490 - schwarz 836480490 - schwarz 511480870 - weiß 836480870 - weiß 511480890 - schwarz 836480890 - schwarz 836480470 511480470 836480490...
  • Seite 106: Ersatzteile Visio 2

    Deutsch RAIS/ - Anleitung für VISIO ersatzteile VISIO 2 pos. anzahl artikelnr. beschreibung handgriff für klappe - komplett 1240905mon luftklappe - komplett 1240990 türgriff 1241015mon kalter griff - komplett 1242410 glasleisten - gemalt VISIO 2l (links) 124205090 glasleisten - rostfrei Visio 2l (links)
  • Seite 107 FIRE ENVIRONMENTALLY FRIENDLY! 5 Eco-friendly advices for sensible heating - common sense both environmentally and economically. 1. Effective lighting. Use small pieces of wood (fir tree) and a suitable fire lighter, for example paraffined wood wool/saw- dust. Open the air damper, so plenty of air is fed to the stove and the gases from the heated wood can burn rapidly.
  • Seite 108 English RAIS/ - User manual for VISIO VISIO 2 - VISIO 3 Revision : Date 27th march 2015 IntRODuctIOn ........................106 WaRRanty ..........................107 SpecIfIcatIOnS ........................108 DIStanceS ..........................109 InStallatIOn InStRuctIOnS ....................113 cOnVectIOn ......................... 114 mateRIal SelectIOn ......................114 chImney ..........................
  • Seite 109: Date

    English RAIS/ - User manual for VISIO Introduction attika thank you for purchasing a RaIS/ wood burning stove. attika a RaIS/ wood burning stove is more than just a heat source. It also shows that you care about design and quality in your home.
  • Seite 110: Warranty

    English RAIS/ - User manual for VISIO WaRRanty attika RaIS/ – wood-burning stoves are tested repeatedly in terms of safety, as well as material and manufacturing quality. We grant warranty on all models, starting with the date of installation.
  • Seite 111: Specifications

    English RAIS/ - User manual for VISIO attika RaIS/ VISIO are inset stoves with a vertically operated door. VISIO 2 has a front glass and a side glass either to the right or left. VISIO 3 has a front glass and 2 side glasses.
  • Seite 112: Distances

    English RAIS/ - User manual for VISIO DIstances Distance from floor to center smoke top outlet Distance from floor to center smoke back outlet Distance from back side to air intake bottom (air system) n: Distance from side to air intake bottom (air system) VISIO 2 with smoke top outlet note that the stove is fitted with a stepless flue collar.
  • Seite 113 English RAIS/ - User manual for VISIO VISIO 2 with smoke back outlet note that the stove is fitted with a stepless flue collar. Røg til ba...
  • Seite 114 English RAIS/ - User manual for VISIO VISIO 3 with smoke top outlet note that the stove is fitted with a stepless flue collar. 218 - 280 - 480  29,5 39,5 29,5...
  • Seite 115 English RAIS/ - User manual for VISIO VISIO 3 with smoke back outlet note that the stove is fitted with a stepless flue collar.
  • Seite 116: Installation Instructions

    English RAIS/ - User manual for VISIO Installation instructions the following pages give instructions for the safe and proper installation of this heating appliance in the uk. these instructions cover the basic principles of installation, although detail may need slight modification to suit particular local site conditions. In all cases the installation must comply with current uk building Regulations, local authority byelaws and other specifications or regulations as they affect the installation of the stove.
  • Seite 117: Convection

    English RAIS/ - User manual for VISIO convection attika RaIS/ stoves are convection stoves. convection means that there is a circulation of air, which ensures that the heat is distributed more evenly throughout the entire room. cold air is sucked in at the base of the stove up through the convection channel, which runs along the stove’s combustion chamber.
  • Seite 118: Chimney

    English RAIS/ - User manual for VISIO During the test, the stove was installed into a test enclosure arrangement made of 12,5 mm fermacell h2O powerboard non-combustible building slabs. the inner side of the test enclosure was insulated with 25 mm mineral wool, type proRox Sl970 Sc from Rockwool.
  • Seite 119: Mounting The Reflektor Plate - Visio 2

    English RAIS/ - User manual for VISIO adequate provision e.g. easily accessible soot door or doors must be provided for sweep- ing the chimney and connecting fluepipe. you should also familiarise yourself with the draught conditions for chimneys with 2 flues.
  • Seite 120: Mounting The Reflector Plate - Visio 3

    English RAIS/ - User manual for VISIO mounting the reflector plate - VISIO 3 the stove is fitted with a Dismount the reflector plate and turn it reflector plate. upside down. mount the plate by reus- ing the screws at the bottom.
  • Seite 121: Installation

    English RAIS/ - User manual for VISIO Installation this appliance may only be installed by a qualified Rais dealer/installer, otherwise the war- ranty is voided. When installing the appliance, all local rules and regulations, including those referring to national and european standards need to be complied with. local authorities and a chim- ney specialist should be contacted prior to set up.
  • Seite 122: Visio 2 - Built-In Dimensions

    English RAIS/ - User manual for VISIO l 50mm Hulmål til VISIO 2 - Fermacell 13 VISIO 2 - built-in dimensions g af Indvendige mål er angivet ved indbygning af Wall opening VISIO 2 - 12.5 mm fermacell with 25 mm mineral wool ovn (uden afdækning).
  • Seite 123 Hulmål til VISIO 2 - Super Isol 50mm attika English RAIS/ - User manual for VISIO Indvendige mål er angivet ved indbygning af Wall opening VISIO 2 - calcium silicate insulating boards (i.e. 50 mm Super Isol og fermatec 225) ovn (uden afdækning).
  • Seite 124 Mål er angivet ved indbygning af ovn uden afdækning. attika English RAIS/ - User manual for VISIO nOte! When installing without outer front cover (accessory) RaIS recommends an air gap of 5 mm between panels and the stove top (see drawing beneath).
  • Seite 125 Indbygningsmål til Visio 2 - Mursten (1249 attika English RAIS/ - User manual for VISIO Indvendige mål er angivet ved indbygning af ovn (uden afd Wall opening VISIO 2 - brick wall Hvis en afdækning indbygges, skal hulmålet øges Wall opening (height x width x depth) min. 432 x 685 x 490 mm (inner dimensions).
  • Seite 126 Opstillings afstand til Visio 2 - Murste attika English RAIS/ - User manual for VISIO Luftgab (indv) I siden og bunden af ovn. nOte! When installing without outer front cover (accessory) RaIS recommends an air gap of 5 Mål er angivet ved indbygning af ovn uden afdækni mm between the bricks and the stove top (see drawing beneath).
  • Seite 127: Visio 2 - Installation Distances

    English RAIS/ - User manual for VISIO VISIO 2 - Installation distances panels - VISIO 2 panel types: • 12.5 mm fermacell with 25 mm mineral wool • 50 mm calcium silicate boards convection areas must be installed above and below the stove.
  • Seite 128 English RAIS/ - User manual for VISIO VISIO 2 - installation distances - panels Distance from side glass to combustible min. 350 mm (e.g. door frame) min. 130 mm Distance from side glass to furniture min. 850 mm Distance from front glass to combustible min.
  • Seite 129 English RAIS/ - User manual for VISIO VISIO 2 - installation distances - panels attentIOn! Insulated chimney (acc.) all the way down to the collar clearance height above burning chamber min. 698 mm convection area is placed just below the sloped plate.
  • Seite 130 English RAIS/ - User manual for VISIO brick wall - VISIO 2 If convection areas are installed above and below the stove, the distances to combustible materials from VISIO 2 panel installation can be applied. If insufficient convection is created, the brick walls may be damaged.
  • Seite 131 English RAIS/ - User manual for VISIO VISIO 2 - installation distances- brick wall Distance from side glass to combustible min. 350 mm (e.g. door frame) - only when installing convection areas above/below the stove. min. 130 mm Distance from side glass to furniture min.
  • Seite 132 English RAIS/ - User manual for VISIO VISIO 2 - installation distances- brick wall clearance height above burning chamber min. 698 mm any convection areas must be placed just below the sloped plate. to guide the hot air out of...
  • Seite 133: Visio 3 - Built-In Dimensions

    English RAIS/ - User manual for VISIO VISIO 3 - built-in dimensions Wall opening VISIO 3 - panels Wall opening (height x width x depth) min. 432 x 770 x 443 mm (inner dimensions). Hulmål til VISIO 3 - Fermacell 13...
  • Seite 134 Indbygningsmål til Visio 2 - Mursten (1249006) attika English RAIS/ - User manual for VISIO Indvendige mål er angivet ved indbygning af ovn (uden afdækning) Hvis en afdækning indbygges, skal hulmålet øges Wall opening VISIO 3 - brick wall svarende til tykkelsen af afdækningen.
  • Seite 135: Visio 3 - Installation Distances

    English RAIS/ - User manual for VISIO VISIO 3 - Installation distances panels - VISIO 3 panel types: • 12.5 mm fermacell with 25 mm mineral wool • 50 mm calcium silicate boards convection areas must be installed above and below the stove.
  • Seite 136 English RAIS/ - User manual for VISIO VISIO 3 - installation distances - panels Distance from side glass to combus- Distance from side glass to combus- tible min. 220 mm (e.g. door frame) tible min. 220 mm (e.g. door frame)
  • Seite 137 English RAIS/ - User manual for VISIO VISIO 3 - installation distances - panels attentIOn! Insulated chimney (acc.) all the way down to the collar clearance height above burning chamber min. 698 mm convection area is placed just below the sloped plate.
  • Seite 138 English RAIS/ - User manual for VISIO brick wall - VISIO 3 If convection areas are installed above and below the stove, the distances to combustible materials from VISIO 2 panel installation can be applied. If insufficient convection is created, the brick walls may be damaged.
  • Seite 139 English RAIS/ - User manual for VISIO VISIO 3 - installation distances- brick wall Distance from side glass to Distance from side glass to combustible min. 220 mm combustible min. 220 mm (e.g. door frame) (e.g. door frame) - only when installing...
  • Seite 140 English RAIS/ - User manual for VISIO VISIO 3 - installation distances- brick wall clearance height above burning chamber min. 698 mm any convection area is placed just below the sloped plate. to guide the hot air out of...
  • Seite 141: Air-System

    English RAIS/ - User manual for VISIO air-system When mounting the air system ensure that the air control system provides fresh air from the outside. In order for the air system to function, you have to ensure in the structure that no vacuum occurs in the housing.
  • Seite 142: For The Installer

    English RAIS/ - User manual for VISIO for the Installer finally before firing the stove for the first time a check should be made to ensure that the assembly and stove installation has been satisfactory and that there are no leaks in any seals in the appliance and appliance connections to the chimney.
  • Seite 143: Drying And Storage

    English RAIS/ - User manual for VISIO ONLY USE RECOMMENDED FUELS the following table shows the calorific value of different types of wood, which have been stored for 2 years, and which have a residual moisture of 15-17%. Wood Kg dry wood pr.
  • Seite 144: Room Ventilation

    English RAIS/ - User manual for VISIO It is not recommended that you turn it down completely. a mistake commonly made is shutting the damper too early because it feels too hot. this results in dark smoke ema- nating from the chimney and the calorific value of the firewood is not being used to its fullest.
  • Seite 145: First Usage

    English RAIS/ - User manual for VISIO first usage a careful start pays off. Start with a small fire, so that the wood burning stove can get accustomed to the high temperature. this gives the best start and any damage is avoided.
  • Seite 146: Lighting And Fuelling

    English RAIS/ - User manual for VISIO lighting and fuelling nOte! If airsystem is connected, the valve must be open. tIpS before firing up: Open a door or window close to the wood burning. If there is a “storm” in the stove...
  • Seite 147 English RAIS/ - User manual for VISIO • When the fire has caught the kindling wood, close the door completely (after approx. 3-10 min., depending on the draft conditions in the chimney). • When the last flames are extinguished and there is a nice layer of embers, add 3-4 pieces wood (about 2-2½...
  • Seite 148: Control

    English RAIS/ - User manual for VISIO nOte! If the fire has burned down too low (too small an ember), it may take longer time to get the fire going again. In order to light up the fire, it is recommended to use kindling wood.
  • Seite 149 Advarsel Advarsel Advarsel attika English RAIS/ - User manual for VISIO Hvis brændet kun ulmer eller ryger, og der tilføres for lidt luft, udvikles der Hvis brændet kun ulmer eller ryger, og der tilføres for lidt luft, udvikles der Hvis brændet kun ulmer eller ryger, og der tilføres for lidt luft, udvikles der Warning!! uforbrændte røggasser.
  • Seite 150: Cleaning And Care

    English RAIS/ - User manual for VISIO cleaning and care glass most woodstoves use a ceramic glass product which is resistant to heat but requires clean- ing to keep its appearance. Soot or opaque marks can easily cleaned if the marks are fresh, however If you leave the...
  • Seite 151: Cleaning The Door Glass - Visio 2

    English RAIS/ - User manual for VISIO cleaning the door glass - VISIO 2 lock the door before cleaning, using the special key (supplied with the stove) wrench the 2 locks above the glass. the front glass is released by wrenching the bracket below and above the side glass.
  • Seite 152: Cleaning The Door Glass - Visio 3

    English RAIS/ - User manual for VISIO cleaning the door glass - VISIO 3 lock the door before cleaning. using the special key (supplied with the stove) wrench the 2 locks (1 on each side) above the glass. the side glass is released by wrenching the bracket below and above the side glass.
  • Seite 153: Cleaning The Combustion Chamber

    English RAIS/ - User manual for VISIO cleaning the combustion chamber Scrape/shovel the ash through the grate in the middle of the stove. the ash tray below is removed and emptied into a non combustible container until it has cooled.
  • Seite 154: Interruption Of Operation

    English RAIS/ - User manual for VISIO the smoke chicane rests on 2 channels. push it forwards, tilt, lower and remove. Remove dirt and dust, and mount When remounting the chicane, secure the parts in reverse order. the plate under locking plate.
  • Seite 155 English RAIS/ - User manual for VISIO Stove is burning too strong could be caused by: • leak around the door seal • chimney draught too large >22 pa, draught control regulator should be installed. Stove is burning too weakly could be caused by: •...
  • Seite 156: Accessories Visio 2 - Visio 3

    English RAIS/ - User manual for VISIO accessories VISIO 2 - VISIO 3 front cover for VISIO 2 front cover for VISIO 2 6 sided - left side - 6 mm thick 6 sided - right side - 6 mm thick...
  • Seite 157 English RAIS/ - User manual for VISIO convection grates - front convection grates - side 511480470 - white 836480470 - white 511480490 - black 836480490 - black 511480870 - white 836480870 - white 511480890 - black 836480890 - black...
  • Seite 158: Spare Parts Visio 2

    English RAIS/ - User manual for VISIO Spare parts VISIO 2 pos. Quantity part no. Description 1240905mon handle for air damper complete 1240990 air damper complete 1241015mon Door handle 1242410 cold hand – kalte hand complete 124205090 glass frames painted Visio 2l...
  • Seite 159 CHAUFFEZ EN RESPECTANT L’ENVIRONNEMENT! 5 conseils pour une combustion raisonnable et respectueuse - une question de bon sens aussi bien pour l’environnement que pour votre porte-monnaie 1. Allumage efficace. Utilisez de petits morceaux de bois (de sapin) et une briquette d’allumage appropriée, par exemple de la laine ou sciure de bois paraffine.
  • Seite 160 Français RAIS/ - Manuel d’utilisateur pour VISIO VISIO 2 - VISIO 3 Revision : Date 27. mars 2015 IntRODuctIOn ........................158 gaRantIe ..........................159 SpécIfIcatIOnS ........................160 DIStanceS ........................... 161 cOnVectIOn ........................165 chOIx DeS matéRIelS pOuR la pOSe ................. 166 chemInée ..........................
  • Seite 161: Date

    Français RAIS/ - Manuel d’utilisateur pour VISIO Introduction attika félicitations pour votre nouveau poêle à bois RaIS/ attika un poêle à bois RaIS/ est bien plus qu’une simple source de chaleur, c’est aussi un symbole de l’importance que vous accordez à décorer votre intérieur en utilisant des produits de qualité...
  • Seite 162: Garantie

    être demandées à RaIS a/S / attika feuer ag ou être consultées sur Internet à l’adresse www.attika.ch.
  • Seite 163: Spécifications

    Français RAIS/ - Manuel d’utilisateur pour VISIO VISIO est un poêle à insert muni d’un couvercle à soulever/abaisser. VISIO 2 comporte un verre avant et un verre latéral, soit pour la droite, soit pour la gauche. VISIO 3 comporte un verre avant et 2 verres latéraux.
  • Seite 164: Distances

    Français RAIS/ - Manuel d’utilisateur pour VISIO Distances Distance du sol au centre de sortie de la fumée en haut Distance du sol au centre de la sortie de fumée en arrière Distance de l’arrière à l’admission d’air en bas (système aIR) n: Distance d’un côté...
  • Seite 165 Français RAIS/ - Manuel d’utilisateur pour VISIO VISIO 2 avec accès par l’arrière notez qu’on peut faire tourner en continu la tubulure de fumée. Røg til ba...
  • Seite 166 Français RAIS/ - Manuel d’utilisateur pour VISIO VISIO 3 avec accès par le haut notez qu’on peut faire tourner en continu la tubulure de fumée. 218 - 280 - 480  29,5 39,5 29,5...
  • Seite 167 Français RAIS/ - Manuel d’utilisateur pour VISIO VISIO 3 avec accès par l’arrière notez qu’on peut faire tourner en continu la tubulure de fumée.
  • Seite 168: Convection

    Français RAIS/ - Manuel d’utilisateur pour VISIO convection attika tous les poêles RaIS/ sont des poêles à convection. le principe de convection l’air froid consiste à faire entrer de dans le système à la base du poêle et à le faire monter à...
  • Seite 169: Choix Des Matériels Pour La Pose

    Français RAIS/ - Manuel d’utilisateur pour VISIO choix des matériels pour la pose On choisira comme matériaux non inflammables des panneaux/briques ayant une valeur d’insulance supérieure à 0,03 m²xk/W. l’insulance est définie comme étant l’épaisseur du mur (en m) divisée par la valeur lambda du mur.
  • Seite 170: Installation

    Français RAIS/ - Manuel d’utilisateur pour VISIO Installation Il importe que le poêle soit correctement installé sur le plan de l’environnement et de la sécurité lors de l’installation du poêle, toutes les normes et résolutions locales, y compris celles faisant référence aux normes nationales et européennes, doivent être respectées.
  • Seite 171: Montage Du Réflecteur - Visio 2

    Français RAIS/ - Manuel d’utilisateur pour VISIO montage du réflecteur - VISIO 2 le poêle est muni d’une plaque Démontez cette plaque et posez-la à de réflecteur sur le côté arrière. l’envers. montez-la avec les mêmes vis (comme indiqué).
  • Seite 172: Protection De Transport - Visio 2 - Visio 3

    Français RAIS/ - Manuel d’utilisateur pour VISIO pliez les 2 échancrures comme indiqué et montez la plaque sur le dessus du poêle. protection de transport - VISIO 2 - VISIO 3 avant l’installation du poêle, il faut retirer la protection de transport : •...
  • Seite 173: Visio 2 - Montage Du Poêle À Insertion

    Français RAIS/ - Manuel d’utilisateur pour VISIO sol 50mm Hulmål til VISIO 2 - Fermacell 13 VISIO 2 - montage du poêle à insertion ning af Indvendige mål er angivet ved indbygning af Dimensions de montage de VISIO 2 - 12,5 mm fermacell avec 25 mm iso- ovn (uden afdækning).
  • Seite 174 Français RAIS/ - Manuel d’utilisateur pour VISIO Hulmål til VISIO 2 - Super Isol 50mm Dimensions de montage de VISIO 2 - de panneaux en silicate de calcium Indvendige mål er angivet ved indbygning af (par example 50 mm Super Isol ou Skamotec 225) ovn (uden afdækning).
  • Seite 175 Mål er angivet ved indbygning af ovn uden afdækning. attika Français RAIS/ - Manuel d’utilisateur pour VISIO RemaRQue! attika en cas de montage sans recouvrement frontal (en accessoires), RaIS/ recommande de laisser une fente d’air de 5 mm entre les panneaux et le haut du poêle (voir le croquis ci-dessous).
  • Seite 176 Français RAIS/ - Manuel d’utilisateur pour VISIO Indbygningsmål til Visio 2 - Mursten (124900 Dimensions de montage de VISIO 2 - brique Indvendige mål er angivet ved indbygning af ovn (uden afdækn taille des orifices (hauteur x largeur x profondeur) minimum 432 x 685 x 490 mm (dimensions intérieures).
  • Seite 177 Opstillings afstand til Visio 2 - Murst attika Français RAIS/ - Manuel d’utilisateur pour VISIO Luftgab (indv) I siden og bunden af ovn. RemaRQue! attika en cas de montage sans recouvrement frontal (en accessoires), RaIS/ recommande Mål er angivet ved indbygning af ovn uden afdækn de laisser une fente d’air de 5 mm entre les panneaux et le haut du poêle...
  • Seite 178: Visio 2 - Distances De Montage

    Français RAIS/ - Manuel d’utilisateur pour VISIO VISIO 2 - distances de montage panneaux - VISIO 2 types de panneaux: • 12,5 mm fermacell med 25 mm isolant en panneau • 50 mm de panneaux en silicate de calcium Des orifices de convection doivent être aménagés au-dessus et en dessous du poêle.
  • Seite 179 Français RAIS/ - Manuel d’utilisateur pour VISIO VISIO 2 - distances de montage - panneaux Distance du verre latéral jusqu’au mur inflammable min. 350 mm (par ex. chambranle) min. 130 mm Distance entre les meubles et le verre latéral min. 850 mm Distance entre le mur inflammable et le verre avant min.
  • Seite 180 Français RAIS/ - Manuel d’utilisateur pour VISIO VISIO 2 - distances de montage - panneaux nOta : cheminée isolée (non fournie) jusqu’en bas vers hauteur libre au-dessus de l’adaptateur de la chambre de combustion sortie de fumée min. 698 mm les orifices de convection sont placés juste sous la...
  • Seite 181 Français RAIS/ - Manuel d’utilisateur pour VISIO murs de briques / mur coupe-feu - VISIO 2 Si des orifices de convection ont été percés au-dessus et en dessous du poêle, les dis- tances par rapport à des éléments inflammables peuvent être mesurées à partir du point d’installation des panneaux á...
  • Seite 182 Français RAIS/ - Manuel d’utilisateur pour VISIO VISIO 2 - distances de montage - murs de briques / mur coupe-feu Distance du verre latéral jusqu’au mur inflammable min. 350 mm (par ex. chambranle) - cette distance n’est valable qu’avec des orifices de convection au-dessus/en-dessous du poêle.
  • Seite 183 Français RAIS/ - Manuel d’utilisateur pour VISIO VISIO 2 - distances de montage - murs de briques / mur coupe-feu hauteur libre au-dessus de la chambre de com- bustion min. 698 mm les orifices de convection éventuels sont placés juste sous la plaque inclinée.
  • Seite 184: Visio 3 - Montage Du Poêle À Insertion

    Français RAIS/ - Manuel d’utilisateur pour VISIO VISIO 3 - montage du poêle à insertion Dimensions de montage de VISIO 3 taille des orifices (hauteur x largeur x profondeur) minimum 432 x 770 x 443 mm (dimensions intérieures). Distance intérieure Types de panneaux jusqu’au mur arrière...
  • Seite 185 Français RAIS/ - Manuel d’utilisateur pour VISIO Indbygningsmål til Visio 2 - Mursten (1249006) Dimensions de montage de VISIO 3 - murs de briques / mur coupe-feu Indvendige mål er angivet ved indbygning af ovn (uden afdækning) Hvis en afdækning indbygges, skal hulmålet øges taille des orifices (hauteur x largeur x profondeur) minimum 432 x 770 x 443 mm (dimensions intérieures).
  • Seite 186: Visio 3 - Distances De Montage

    Français RAIS/ - Manuel d’utilisateur pour VISIO VISIO 3 - distances de montage panneaux - VISIO 3 types de panneaux: • 12,5 mm fermacell med 25 mm isolant en panneau • 50 mm de panneaux en silicate de calcium Des orifices de convection doivent être aménagés au-dessus et en dessous du poêle.
  • Seite 187 Français RAIS/ - Manuel d’utilisateur pour VISIO VISIO 3 - distances de montage - panneaux Distance du verre latéral jusqu’au Distance du verre latéral jusqu’au mur inflammable min. 220 mm mur inflammable min. 220 mm (par ex. chambranle) (par ex. chambranle)
  • Seite 188 Français RAIS/ - Manuel d’utilisateur pour VISIO VISIO 3 - distances de montage - panneaux nOta : cheminée isolée (non fournie) jusqu’en bas vers l’adaptateur de sortie de fumée hauteur libre au-dessus de la chambre de combustion min. 698 mm les orifices de convection sont placés juste sous la...
  • Seite 189 Français RAIS/ - Manuel d’utilisateur pour VISIO murs de briques / mur coupe-feu - VISIO 3 Si des orifices de convection ont été percés au-dessus et en dessous du poêle, les dis- tances par rapport à des éléments inflammables peuvent être mesurées à partir du point d’installation des panneaux á...
  • Seite 190 Français RAIS/ - Manuel d’utilisateur pour VISIO VISIO 3 - distances de montage - murs de briques / mur coupe-feu Distance du verre latéral jusqu’au Distance du verre latéral jusqu’au mur inflammable min. 220 mm mur inflammable min. 220 mm (par ex.
  • Seite 191 Français RAIS/ - Manuel d’utilisateur pour VISIO VISIO 3 - distances de montage - murs de briques / mur coupe-feu hauteur libre au-dessus de la chambre de com- bustion min. 698 mm les orifices de convection éventuels sont placés juste sous la plaque inclinée.
  • Seite 192: Système D'air

    Français RAIS/ - Manuel d’utilisateur pour VISIO Système d’air lors du montage du système d’air, on veille à ce que le système de régulation d’air soit alimenté en air frais par l’extérieur. pour garantir le bon fonctionnement du système d’air, la construction doit être faite de façon à...
  • Seite 193: Bois De Chauffage

    Français RAIS/ - Manuel d’utilisateur pour VISIO bois de chauffage le poêle a été testé conformément à la norme européenne en13240:2001, en13240:2001/a2:2004 et à la norme nS 3058/3059 pour la combustion du bouleau sec et fendu et approuvé également pour la combustion de l’arbre à feuilles/conifère. le bois de chauffage ne devrait contenir que 15-20 % d’eau et avoir un maximum longueur de...
  • Seite 194: Séchage Et Stockage Du Bois

    Français RAIS/ - Manuel d’utilisateur pour VISIO Séchage et stockage du bois le bois a besoin de temps pour sécher: séchage à l’air correct prend env. 2 ans. Voici quelques conseils: • Stocker le bois scié, fendu et empilé dans un endroit aéré, ensoleillé protégé de la pluie (côté...
  • Seite 195: Ventilation

    Français RAIS/ - Manuel d’utilisateur pour VISIO Ventilation l’installation d’aspiration/de hotte aspirante (cuisine) ne doit pas se trouver dans la même pièce que le poêle, car il peut en résulter que le poêle dégage des gaz de fumée vers la pièce.
  • Seite 196: Premier Allumage

    Français RAIS/ - Manuel d’utilisateur pour VISIO premier allumage un démarrage prudent s’avère payant. commencez avec un peu de bois, afin que le poêle puisse s’habituer à la haute température. c’est la meilleure façon de commencer et d’éviter les dégâts éventuels.
  • Seite 197 Français RAIS/ - Manuel d’utilisateur pour VISIO • allumer le feu • Réglez le volet d’air en position complètement ouverte - position 3 (par environ 15 minutes), et puis en position 2. • fermez complètement le couvercle et soulevez-le par sa poignée (fente d’air de 1 à...
  • Seite 198: Contrôle

    Français RAIS/ - Manuel d’utilisateur pour VISIO • au besoin, placez la poignée de tirette sur la position 3 (complètement à droite) pendant 2 à 5 minutes pour faire démarrer le feu • placez ensuite la tirette entre les positions 1 et 2 (voir ‘Réglage de la tirette’).
  • Seite 199 Advarsel Advarsel Advarsel attika Français RAIS/ - Manuel d’utilisateur pour VISIO Hvis brændet kun ulmer eller ryger, og der tilføres for lidt luft, udvikles der Hvis brændet kun ulmer eller ryger, og der tilføres for lidt luft, udvikles der Hvis brændet kun ulmer eller ryger, og der tilføres for lidt luft, udvikles der Attention !! uforbrændte røggasser.
  • Seite 200: Nettoyage Et Entretien

    être lubrifiées au besoin. nous recom- mandons d’avoir exclusivement recours à l’aérosol de lubrification que nous proposons (www.attika-shop.ch), car l’utilisation d’autres produits pourraient entraîner la formation d’odeurs et de résidus.
  • Seite 201: Nettoyage Du Verre De Couvercle - Visio 2

    Français RAIS/ - Manuel d’utilisateur pour VISIO nettoyage du verre de couvercle - VISIO 2 Verrouillez le couvercle avant de le nettoyer. avec la tirette spéciale (fournie avec le poêle), tournez les (2) verrous vers l’extérieur par dessus le verre.
  • Seite 202: Nettoyage Du Verre De Couvercle - Visio 3

    Français RAIS/ - Manuel d’utilisateur pour VISIO nettoyage du verre de couvercle - VISIO 3 Verrouillez le couvercle avant de le nettoyer. avec la tirette spéciale (fournie avec le poêle), tournez les (1) verrous vers l’extérieur par dessus le verre.
  • Seite 203: Nettoyage De La Chambre De Combustion

    Français RAIS/ - Manuel d’utilisateur pour VISIO nettoyage de la chambre de combustion la cendre est raclée/pelletée dans la grille au milieu du poêle. le cendrier sous le poêle peut être extrait et vidé dans un récipient non inflammable jusqu’à ce qu’il ait refroidi.
  • Seite 204: Diagnostic Des Pannes

    Français RAIS/ - Manuel d’utilisateur pour VISIO la chicane de fumée repose sur 2 con- duites; poussez-la vers l’avant, inclinez-la, abaissez-la et enlevez-la ensuite. goupille goupille lorsque la chicane est montée, évacuez la saleté et la poussière, la plaque est fixée sous la plaque et mettez les pièces en place...
  • Seite 205 Français RAIS/ - Manuel d’utilisateur pour VISIO le poêle brûle trop vigoureusement cela peut être dû • à un défaut d’étanchéité des joints du couvercle • trop de tirage dans la cheminée >22 pa, une tirette de régulation doit être montée.
  • Seite 206: Accessoires Visio 2 - Visio 3

    Français RAIS/ - Manuel d’utilisateur pour VISIO accessoires VISIO 2 - VISIO 3 Recouvrement frontal - VISIO 2 Recouvrement frontal - VISIO 2 6 faces - gauche - 6 mm épais 6 faces - droit - 6 mm épais...
  • Seite 207 Français RAIS/ - Manuel d’utilisateur pour VISIO grille de convection - avant grille de convection - lateral 511480470 - blanc 836480470 - blanc 511480490 - noir 836480490 - noir 511480870 - blanc 836480870 - blanc 511480890 - noir 836480890 - noir...
  • Seite 208: Pièces De Rechange Visio 2

    Français RAIS/ - Manuel d’utilisateur pour VISIO pièces de rechange VISIO 2 no.produit Description Ref. nombre poignée pour volet - complète 1240905mon Volet d’air 1240990 poignées de porte 1241015mon poignée froide - complète 1242410 moulures de verre - peintes - VISIO 2l (gauche)
  • Seite 209 FYR MILJØVENNLIGT! 5 miljøvennlige råd til fornuftig fyring - sunt fornuft for både miljø og økonomisk. 1. Effektiv optænding. Bruk små stykker av tre (gran) og pas- sende tennbrikett, f.eks. vokset træfiberruller/sagflis. Skru op lufttilførselen, slik at rikelig med luft blir tilført til ovnen, og gassene fra det oppvarmede trevirke kan brenne raskt.
  • Seite 210 Norsk RAIS/ - Brukerveiledning til VISIO VISIO 2 - VISIO 3 Revision : Dato 27. marts 2015 InnleDnIng ........................... 208 gaRantI ..........................209 SpeSIfIkaSjOneR ........................210 aVStanDeR..........................211 kOnVekSjOn ......................... 215 Valg aV mateRIale fOR VeggeR..................216 SkORSteIn ..........................216 InStallaSjOn ........................
  • Seite 211: Dato

    Norsk RAIS/ - Brukerveiledning til VISIO Innledning attika gratulerer med din nye RaIS/ peisovn. attika en RaIS/ peisovn er mer en bare en varmekilde, den er også et uttrykk for at du legger vekt på design og høy kvalitet i hjemmet.
  • Seite 212: Garanti

    Norsk RAIS/ - Brukerveiledning til VISIO gaRantI attika RaIS/ peisovner kontrolleres i flere omganger når det gjelder sikkerhet, samt kvaliteten på materialer og bearbeidelse av disse. Vi gir garanti på alle modeller, og garan- tiperioden gjelder fra installasjonsdatoen. garantien dekker: •...
  • Seite 213: Spesifikasjoner

    Norsk RAIS/ - Brukerveiledning til VISIO attika RaIS/ VISIO er innsatsovne med heve/senke-dør. VISIO 2 har frontglass og sideglass enten til høyre eller venstre. VISIO 3 har frontglass og 2 sideglass. Spesifikasjoner DtI ref.: 300-elab-2080-en / 300-elab-2080-nS VISIO 2...
  • Seite 214: Avstander

    Norsk RAIS/ - Brukerveiledning til VISIO avstander avstand fra gulv til senter røykuttak topp avstand fra gulv til senter røykuttak bak avstand fra bakside til luftinntak i bunnen (air system) n: avstand fra side til luftinntak i bunnen (air system) VISIO 2 med røykuttak topp...
  • Seite 215 Norsk RAIS/ - Brukerveiledning til VISIO VISIO 2 med røykuttak bak merk at røykuttak kan dreje trinnløs. Røgrør til bage...
  • Seite 216 Norsk RAIS/ - Brukerveiledning til VISIO VISIO 3 med røykuttak topp merk at røykuttak kan dreje trinnløs. 218 - 280 - 480  29,5 39,5 29,5...
  • Seite 217 Norsk RAIS/ - Brukerveiledning til VISIO VISIO 3 med røykuttak bak merk at røykuttak kan dreje trinnløs.
  • Seite 218: Konveksjon

    Norsk RAIS/ - Brukerveiledning til VISIO konveksjon attika RaIS/ -ovner er konnveksjonovner. konveksjon betyr at det oppstår luftsirkulasjon, så varmen fordeles jevnere i hele rommet. kalde luften trekkes inn i bunnen av ovnen og går opp langs ovnens brennkammer der luften varmes opp.
  • Seite 219: Valg Av Materiale For Vegger

    Norsk RAIS/ - Brukerveiledning til VISIO Valg av materiale for vegger Ikke brennbar paneler/murstein bør velges med en isolansværdi større enn 0,03 m k/W. Isolans (termisk motstand) er definert som tykkelsen (i m) dividert med veggens lambda verdi. ta kontakt med din installatør/feier.
  • Seite 220: Installasjon

    Norsk RAIS/ - Brukerveiledning til VISIO Installasjon Det er viktigt at ovnen installeres korrekt av hensyn til både miljø og sikkerhet. Ved installasjon av ovnen skal alle lokale regler og forskrifter, inkludert de som henviser til nasjonale og europeiske standarder, overholdes.
  • Seite 221: Montering Av Reflektorplate - Visio 2

    Norsk RAIS/ - Brukerveiledning til VISIO montering av reflektorplate - VISIO 2 Demonter reflektorplaten og snu Ovnen er utstyret med en den på hovet. monter platen med reflektorplate på baksiden. de samme skruene (som vist). montering av reflektorplate - VISIO 3...
  • Seite 222: Transportsikring - Visio 2 - Visio 3

    Norsk RAIS/ - Brukerveiledning til VISIO bøy de 2 utskjæringene som vist og monter platen oppå ovnen. transportsikring - VISIO 2 - VISIO 3 før ovnen installeres fjernes transportsikringen: • på VISIO 2 er der 1 skrue på siden...
  • Seite 223: Visio 2 - Innbyggning

    Norsk RAIS/ - Brukerveiledning til VISIO sol 50mm Hulmål til VISIO 2 - Fermacell 13 VISIO 2 - Innbyggning ning af Indvendige mål er angivet ved indbygning af Innbygningsmål til VISIO 2 - 12,5 mm fermacell med 25mm brannisolasjon ovn (uden afdækning).
  • Seite 224 Hulmål til VISIO 2 - Super Isol 50mm attika Norsk RAIS/ - Brukerveiledning til VISIO Indvendige mål er angivet ved indbygning af Innbygningsmål til VISIO 2 - kalsium silikat paneler / brannmur (f. eks. 50 mm Super Isol eller fermatec 225) ovn (uden afdækning).
  • Seite 225 Mål er angivet ved indbygning af ovn uden afdækning. attika Norsk RAIS/ - Brukerveiledning til VISIO meRk! Ved innbygging uten fronttildekking (tilbehør) anbefaler RaIS at det er en luftspalte på 5 mm mellom panelene og toppen av ovnen (se skisse nedenfor).
  • Seite 226 Norsk RAIS/ - Brukerveiledning til VISIO Indbygningsmål til Visio 2 - Mursten (124900 Innbygningsmål til VISIO 2 - murvegg Indvendige mål er angivet ved indbygning af ovn (uden afdækn hulmål (høyde x bredde x dybde) min. 432 x 685 x 490 mm (innvendig mål).
  • Seite 227 Opstillings afstand til Visio 2 - Murst attika Norsk RAIS/ - Brukerveiledning til VISIO Luftgab (indv) I siden og bunden af ovn. meRk! Ved innbygging uten fronttildekking (tilbehør) anbefaler RaIS at det er en luftspalte på 5 Mål er angivet ved indbygning af ovn uden afdækn mm mellom mursteine og toppen av ovnen (se skisse nedenfor).
  • Seite 228: Visio 2 - Opstillingsavstande

    Norsk RAIS/ - Brukerveiledning til VISIO VISIO 2 - opstillingsavstande paneler / brannmur - VISIO 2 paneltyper: • 12,5 mm fermacell med 25 mm brannisolasjon • 50 mm kalsium silikat / brannmur Det må bygges inn konveksjonshull over og under ovnen.
  • Seite 229 Norsk RAIS/ - Brukerveiledning til VISIO VISIO 2 - opstillingsavstande - paneler / brannmur avstand fra sideglass til brennbart min. 350 mm (f.eks. dørkarm) min. 130 mm møbleringsavstand fra sideglass min. 850 mm avstand til brennbart fra frontglass min. 300 mm...
  • Seite 230 Norsk RAIS/ - Brukerveiledning til VISIO VISIO 2 - opstillingsavstande - paneler / brannmur ObS!! Isoleret skorstein (medfølger ikke) helt ned til røykavgangsadapter frihøyde over brannkammer min. 698 mm konvektionshul plasseres rett under skråplaten. for å veilede den varme luften...
  • Seite 231 Norsk RAIS/ - Brukerveiledning til VISIO murvegg - VISIO 2 Dersom det bygges inn konveksjonshull over og under ovnen, kan avstanden til brennbart overføres fra paneloppsettet til VISIO 2. hvis det ikke er nok ventilasjon, kan det føre til skade på murveggene.
  • Seite 232 Norsk RAIS/ - Brukerveiledning til VISIO VISIO 2 - opstillingsavstande - murvegg avstand fra sideglass til brennbart min. 350 mm (f.eks. dørkarm) - gjelder kun med konveksjons- hull over/under ovnen. møbleringsavstand fra min. 130 mm sideglass min. 850 mm avstand til brennbart fra frontglass min.
  • Seite 233 Norsk RAIS/ - Brukerveiledning til VISIO VISIO 2 - opstillingsavstande - murvegg frihøyde over brannkammer min. 698 mm mulig konvektionshul plasseres rett under skråplaten. Reflektorplate for å veilede den varme luften ut av konvektionsristene, anbefaler vi å installere en...
  • Seite 234: Visio 3 - Innbyggning

    Norsk RAIS/ - Brukerveiledning til VISIO VISIO 3 - Innbyggning Innbygningsmål til VISIO 3 - paneler / brannmur hulmål (høyde x bredde x dybde) min. 432 x 770 x 443 mm (innvendig mål). Hulmål til VISIO 3 - Fermacell 13...
  • Seite 235 Indbygningsmål til Visio 2 - Mursten (1249006) attika Norsk RAIS/ - Brukerveiledning til VISIO Indvendige mål er angivet ved indbygning af ovn (uden afdækning) Hvis en afdækning indbygges, skal hulmålet øges Innbygningsmål til VISIO 3 - murvegg svarende til tykkelsen af afdækningen.
  • Seite 236: Visio 3 - Opstillingsavstande

    Norsk RAIS/ - Brukerveiledning til VISIO VISIO 3 - opstillingsavstande paneler / brannmur - VISIO 3 paneltyper: • 12,5 mm fermacell med 25 mm brannisolasjon • 50 mm kalsium silikat / brannmur Det må bygges inn konveksjonshull over og under ovnen.
  • Seite 237 Norsk RAIS/ - Brukerveiledning til VISIO VISIO 3 - opstillingsavstande - paneler / brannmur avstand fra sideglass til brennbart avstand fra sideglass til brennbart min. 220 mm (f.eks. dørkarm) min. 220 mm (f.eks. dørkarm) møbleringsavstand fra møbleringsavstand fra sideglass min. 750 mm sideglass min.
  • Seite 238 Norsk RAIS/ - Brukerveiledning til VISIO VISIO 3 - opstillingsavstande - paneler / brannmur ObS!! Isoleret skorstein (medfølger ikke) helt ned til røykavgangsadapter frihøyde over brannkammer min. 698 mm konvektionshul plasseres rett under skråplaten. for å veilede den varme luften...
  • Seite 239 Norsk RAIS/ - Brukerveiledning til VISIO murvegg - VISIO 3 Dersom det bygges inn konveksjonshull over og under ovnen, kan avstanden til brennbart overføres fra paneloppsettet til VISIO 2. hvis det ikke er nok ventilasjon, kan det føre til skade på murveggene.
  • Seite 240 Norsk RAIS/ - Brukerveiledning til VISIO VISIO 3 - opstillingsavstande - murvegg avstand fra sideglass til brennbart avstand fra sideglass til brennbart min. 220 mm (f.eks. dørkarm) min. 220 mm (f.eks. dørkarm) - gjelder kun med konveksjons- - gjelder kun med konveksjons- hull over/under ovnen.
  • Seite 241 Norsk RAIS/ - Brukerveiledning til VISIO VISIO 3 - opstillingsavstande - murvegg frihøyde over brannkammer min. 698 mm mulig konvektionshul plasseres rett under skråplaten. for å veilede den varme luften ut av konvektionsristene, anbefaler vi å installere en ikke-brennbar isolerende plate...
  • Seite 242: Air-System

    Norsk RAIS/ - Brukerveiledning til VISIO air-system I alle nybygg anbefaler vi på det sterkeste at det klargjøres for direkte tilførsel av luft uten- fra. utilstrekkelig tilførsel av luft utenfra kan medføre undertrykk i rommet der ildstedet står, og dermed dårlig forbrenning, dårligere utnyttelse av veden og nedsoting av pipa.
  • Seite 243: Ved

    Norsk RAIS/ - Brukerveiledning til VISIO Ovnen er testet iht. en 13229:2001, en 13229:2001/a1:2003, en 13229:2001/a2:2004 og nS 3058/3059 for fyring med kløvet, tørr bjørk, og godkjent for løvtre/bartre. Veden skal ha en fuktighet på 15-20 % og en maksimal lengde på 30 cm.
  • Seite 244: Tørkning Og Lagring

    Norsk RAIS/ - Brukerveiledning til VISIO tørkning og lagring Ved trenger tid til å tørke. en korrekt lufttørking tar cirka to år. her er noen tips: • Oppbevar treet kappet, kløvd og stablet på et luftig, solrikt sted beskyttet mot regn (sørsiden av huset er spesielt velegnet).
  • Seite 245: Ventilation

    Norsk RAIS/ - Brukerveiledning til VISIO Ventilation Det må ikke være en avtrekksventilasjon / vifte (kjøkken) i samme rom som ovnen da dette kan føre til at ovnen slipper ut røyk inn i rommet. Ovnen trenger permanent og tilstrekkelig luft for å operere trygt og effektivt. Det kan installeres permanent lufttilførsel til rommet til ovnen forbrenningsluft (se avsnittet om air...
  • Seite 246: Opptenning Første Gang

    Norsk RAIS/ - Brukerveiledning til VISIO Opptenning første gang Det lønner seg å begynne forsiktig. Start med et lite bål, slike at peisovnen venner seg til de høye temperaturene. Da får de en god innkjøring og unngår å skade ovnen.
  • Seite 247 Norsk RAIS/ - Brukerveiledning til VISIO • tenn ilden. • Sett spjeldet i pos. 3 (ca. 15 min.), deretter i pos. 2. • lukk døren og sette den på gløtt - løft i dørhåndtaket (luftgab på 1-2 cm). • når ilden har tak i opptenningsved, lukkes døren helt (etter ca.
  • Seite 248: Kontroll

    Norsk RAIS/ - Brukerveiledning til VISIO • hvis det er nødvendig, sett spjeldhåndtaket i posisjon 3 (helt til høyre) i 2-5 min for å få ‘fart’ på ilden. • Sett spjeldet mellem pos. 1 til pos. 2 ( se ‘Innstilling av spjeldet’) meRk! Dersom ilden har brent for langt ned (for lite glødelag), kan det ta lengere tid å...
  • Seite 249 Advarsel Advarsel Advarsel attika Norsk RAIS/ - Brukerveiledning til VISIO Hvis brændet kun ulmer eller ryger, og der tilføres for lidt luft, udvikles der Hvis brændet kun ulmer eller ryger, og der tilføres for lidt luft, udvikles der Hvis brændet kun ulmer eller ryger, og der tilføres for lidt luft, udvikles der ADVARSEL!! uforbrændte røggasser.
  • Seite 250: Rengjøring Og Pleie

    Norsk RAIS/ - Brukerveiledning til VISIO Rengjøring og pleie peisovn og skorstein skal kontrolleres av en feier en gang i året. Ved rengjøring og pleie skal ovnen være kald. hvis glasset er tilsotet: • Rengjør glasset regelmessig og bare når det er kaldt, ellers brenner sot seg fast.
  • Seite 251: Rengjøring Av Dørglass - Visio 2

    Norsk RAIS/ - Brukerveiledning til VISIO Rengjøring av dørglass - VISIO 2 Døren låses før den rengjøres. med spesialnøkkelen (levert med ovnen) vris låsen (2 stk.) over glasset av. frontglasset frigjøres ved å vri beslaget over og under glasset av.
  • Seite 252: Rengjøring Av Dørglass - Visio 3

    Norsk RAIS/ - Brukerveiledning til VISIO Rengjøring av dørglass - VISIO 3 Døren låses før den rengjøres. med spesialnøkkelen (levert med ovnen) vris låsen (1 stk.i hver side) over glasset av. Sideglasset frigjøres ved å vri beslaget over og under glasset av.
  • Seite 253: Rengjøring Av Brennkammer

    Norsk RAIS/ - Brukerveiledning til VISIO Rengjøring av brennkammer asken skrapes/skyfles ned i risten i midten av ovnen. askebakken under ovnen kan tas ut og tømmes i en ikke brennbar beholder til den er fullstendig avkjølt. kald aske kan kastes sammen med vanlig husholdningsavfall.
  • Seite 254: Driftsforstyrrelser

    Norsk RAIS/ - Brukerveiledning til VISIO Røyksjikanen hviler på 2 kanaler; skyv den forover, tilt og senk den og deretter fjern den. stift stift fjern skitt og støv, og sett delene på når sjikanen monteres, festes platen plass i omvendt rekkefølge.
  • Seite 255 Norsk RAIS/ - Brukerveiledning til VISIO hvis det brenner for sterkt i ovnen: kan skyldes • utetthet ved ovnsdørpakningen • for stor skorsteinstrekk >22 pa, reguleringsspjeld bør monteres. hvis det brenner for svakt i ovnen: kan skyldes • for lite ved •...
  • Seite 256: Tilbehør Visio 2 - Visio 3

    Norsk RAIS/ - Brukerveiledning til VISIO tilbehør VISIO 2 - VISIO 3 frontafdækning til VISIO 2 frontafdækning til VISIO 2 6 sidet - venstre - 6 mm tykk 6 sidet - høyre - 6 mm tykk 124142080 - rustfritt...
  • Seite 257 Norsk RAIS/ - Brukerveiledning til VISIO konvektionsrist - front konvektionsrist - side 511480470 - hvit 836480470 - hvit 511480490 - svart 836480490 - svart 511480870 - hvit 836480870 - hvit 511480890 - svart 836480890 - svart 836480470 511480470 836480490...
  • Seite 258: Reservedeler Visio 2

    Norsk RAIS/ - Brukerveiledning til VISIO Reservedeler VISIO 2 pos. antall Varenr. beskrivelse håndtak for spjeld - komplett 1240905mon Spjæld - komplet 1240990 håndtak for dør 1241015mon kaldt håndtak - komplett 1242410 glasslister - malt VISIO 2l (venstre) 124205090...
  • Seite 259: Testrapport Visio (Forside)

    testrapport VISIO (forside)
  • Seite 261 ELDA MILJÖVÄNLIGT! 5 miljövänliga råd för att elda klokt - sunt förnuft både för miljön og plånboken. 1. Effektiv tänding. Använd tunna träbitar/flisor (gran) och lämp- ligt tändblock, t.ex. paraffinerat sågspån. Öppna luftspjället och tilför rikligt med luft, så att gaserna från den uppvärmda veden förbränns snabbt.
  • Seite 262 Svensk RAIS/ - Bruksanvisning til VISIO VISIO 2 - VISIO 3 Revision : Dato 27. mars 2015 IntRODuktIOn ........................260 gaRantI ..........................261 SpecIfIkatIOneR ........................262 aVStånD ..........................263 kOnVektIOn ........................267 Val aV mateRIal föR InbyggnaD ..................268 SkORSten ..........................
  • Seite 263: Introduktion

    Svensk RAIS/ - Bruksanvisning til VISIO Introduktion attika gratulerar till din nya braskamin från RaIS/ attika en RaIS/ kamin är mer än bara en värmekälla, den är också ett uttryck för att du lägger vikt vid design och hög kvalitet i ditt hem.
  • Seite 264: Garanti

    Svensk RAIS/ - Bruksanvisning til VISIO gaRantI attika RaIS/ braskaminer kontrolleras i flera omgångar avseende säkerhet samt kvalitet på material och bearbetning. garantin gäller amtliga modeller och garantiperioden inleds det datum då kaminen installerass. garantin omfattar: • dokumenterade funktionsfel på grund av felaktig bearbetning •...
  • Seite 265: Specifikationer

    Svensk RAIS/ - Bruksanvisning til VISIO VISIO är en insatskamin med höj- och sänkbar lucka. VISIO 2 har frontglas och sidoglas antingen till höger eller till vänster. VISIO 3 har frontglas och 2 sidoglas. Specifikationer DtI ref.: 300-elab-2080-en / 300-elab-2080-nS...
  • Seite 266: Avstånd

    Svensk RAIS/ - Bruksanvisning til VISIO avstånd avstånd från golv till centrum rökutgång topplatta avstånd från golv till centrum rökutgång baksida avstånd från baksida till luftintag i botten (air-system) n: avstånd från sida till luftintag i botten (air-system) VISIO 2 med rökutgång från ovansida Observera at rökstosen kan vridas steglöst.
  • Seite 267 Svensk RAIS/ - Bruksanvisning til VISIO VISIO 2 med rökutgång från baksida Observera at rökstosen kan vridas steglöst. Røg til ba...
  • Seite 268 Svensk RAIS/ - Bruksanvisning til VISIO VISIO 3 med rökutgång från ovansida Observera at rökstosen kan vridas steglöst. 218 - 280 - 480  29,5 39,5 29,5...
  • Seite 269 Svensk RAIS/ - Bruksanvisning til VISIO VISIO 3 med rökutgång från baksida Observera at rökstosen kan vridas steglöst.
  • Seite 270: Konvektion

    Svensk RAIS/ - Bruksanvisning til VISIO konvektion attika RaIS/ kamin är en konvektionskamin. konvektion betyder, att det uppstår en luftcirkulation som gör att värmen fördelas jämnare i hela rummet. kalla luften sugs in vid kaminens botten och stiger upp längs kaminens brännkam- mare, samtidigt som den värms upp.
  • Seite 271: Val Av Material För Inbyggnad

    Svensk RAIS/ - Bruksanvisning til VISIO Val av material för inbyggnad material väljs paneler/mursten med ett isoleringsvärde som är större än brännsäker 0,03 m k/W. Isoleringsvärde definieras som väggens tjocklek (i m) dividerat med väggens lambdavärde. Rådgör med installatören/sotningsmästaren.
  • Seite 272: Installation

    Svensk RAIS/ - Bruksanvisning til VISIO Installation Det är viktigt att kaminen blir korrekt installerad av både miljö och säkerhetsskäl. Vid installation av kaminen ska alla lokala regler och föreskrifter följas, inklusive dem som hänvisar till nationella och europeiska standarder. Du bör kontakta de lokala myndighet- erna och en sotarmästare före installationen.
  • Seite 273: Montering Av Reflektorplåt - Visio 2

    Svensk RAIS/ - Bruksanvisning til VISIO montering av reflektorplåt - VISIO 2 kaminen är utrustad med en Demontera reflektorplåten och vänd reflektorplåt på baksidan. den upp och ner. montera plåten med samma skruvar (enligt anvisning). montering av reflektorplåt - VISIO 3 kaminen är utrustad med en...
  • Seite 274: Transport Säkerhet - Visio 2 - Visio 3

    Svensk RAIS/ - Bruksanvisning til VISIO böj de 2 utskärningarna enligt anvisning och montera plåten ovanpå kaminen. transport säkerhet - VISIO 2 - VISIO 3 Innan kaminen installeras ska transportsäkringen avlägsnas: • på VISIO 2 sitter det 1 skruv på sidan...
  • Seite 275: Visio 2 - Inbyggnad Av Insatskamin

    Svensk RAIS/ - Bruksanvisning til VISIO sol 50mm Hulmål til VISIO 2 - Fermacell 13 VISIO 2 - Inbyggnad av insatskamin ning af Indvendige mål er angivet ved indbygning af Inbyggnadsmått til VISIO 2 - 12,5 mm fermacell med 25 mm brandbats ovn (uden afdækning).
  • Seite 276 Hulmål til VISIO 2 - Super Isol 50mm attika Svensk RAIS/ - Bruksanvisning til VISIO Indvendige mål er angivet ved indbygning af Inbyggnadsmått til VISIO 2 - kalciumsilikat paneler (t.ex. 50 mm Super Isol eller Skamotec 225) ovn (uden afdækning).
  • Seite 277 Mål er angivet ved indbygning af ovn uden afdækning. attika Svensk RAIS/ - Bruksanvisning til VISIO ObS! Vid inbyggnad utan frontbeklädnad (tillbehör) rekommenderar RaIS en luftspalt på 5 mm mellan paneler och kaminens ovansida (se skiss nedan). luftspalt (invändig) längst upp på kaminen.
  • Seite 278 Svensk RAIS/ - Bruksanvisning til VISIO Indbygningsmål til Visio 2 - Mursten (124900 Inbyggnadsmått til VISIO 2 - tegel Indvendige mål er angivet ved indbygning af ovn (uden afdækn hål mått (höjd x bredd x djup) min. 432 x 685 x 490 mm (indv. mått).
  • Seite 279 Opstillings afstand til Visio 2 - Murst attika Svensk RAIS/ - Bruksanvisning til VISIO Luftgab (indv) I siden og bunden af ovn. ObS! Vid inbyggnad utan frontbeklädnad (tillbehör) rekommenderar RaIS en luftspalt på 5 mm Mål er angivet ved indbygning af ovn uden afdækn mellan paneler och kaminens ovansida (se skiss nedan).
  • Seite 280: Visio 2 - Monteringsavstånd

    Svensk RAIS/ - Bruksanvisning til VISIO VISIO 2 - monteringsavstånd paneler - VISIO 2 paneltyper: • 12,5 mm fermacell med 25 mm brandbatts • 50 mm kalciumsilikat paneler Det ska byggas in konvektionshål över och under kaminen. uppbyggnad av snedställd plåt, bakre vägg och sidovägg...
  • Seite 281 Svensk RAIS/ - Bruksanvisning til VISIO VISIO 2 - monteringsavstånd - paneler avstånd från sidoglas till brännbart material min. 350 mm (t.ex. dörrkarm) min. 130 mm möbleringsavstånd från sidoglas min. 850 mm avstånd till brännbart material från frontglas min. 300 mm alternativ Icke brännbar vägg...
  • Seite 282 Svensk RAIS/ - Bruksanvisning til VISIO VISIO 2 - monteringsavstånd - paneler ObS! Isolerad skorsten (medföljer ej) ända ner till adapter för rökutgång fri höjd över brännkammare min. 698 mm. konvektionshål placeras direkt under den snedställda plåten för att rikta den varma luften Reflektorplåt...
  • Seite 283 Svensk RAIS/ - Bruksanvisning til VISIO tegel - VISIO 2 Om man bygger in konvektionshål över och under kaminen, kan avstånden till brännbart överföras från de monterade panelerna til VISIO 2. Om man inte lyckas skapa tillräcklig konvektion kan det uppstå skador på väggar av tegel.
  • Seite 284 Svensk RAIS/ - Bruksanvisning til VISIO VISIO 2 - monteringsavstånd- tegel avstånd från sidoglas till bränn- bart material min. 350 mm (t.ex. dörrkarm) - gäller endast vid kon- vektionshål över/under kaminen. min. 130 mm möbleringsavstånd från sidoglas min. 850 mm avstånd till brännbart material...
  • Seite 285 Svensk RAIS/ - Bruksanvisning til VISIO VISIO 2 - monteringsavstånd- tegel fri höjd över brännkammare min. 698 mm eventuella konvektionshål placeras direkt under den snedställda plåten. Reflektorplåt för att rikta den varma luften ut genom monterade konvek- tionsgaller måste man montera avstånd från reflektorplåt...
  • Seite 286: Visio 3 - Inbyggnad Av Insatskamin

    Svensk RAIS/ - Bruksanvisning til VISIO VISIO 3 - Inbyggnad av insatskamin Inbyggnadsmått til VISIO 3 - paneler hål mått (höjd x bredd x djup) min. 432 x 770 x 443 mm (indv. mått). Hulmål til VISIO 3 - Fermacell 13...
  • Seite 287 Svensk RAIS/ - Bruksanvisning til VISIO Indbygningsmål til Visio 2 - Mursten (1249006) Inbyggnadsmått til VISIO 3 - tegel Indvendige mål er angivet ved indbygning af ovn (uden afdækning) Hvis en afdækning indbygges, skal hulmålet øges hål mått (höjd x bredd x djup) min. 432 x 770 x 443 mm (indv. mått).
  • Seite 288: Visio 3 - Monteringsavstånd

    Svensk RAIS/ - Bruksanvisning til VISIO VISIO 3 - monteringsavstånd paneler - VISIO 3 paneltyper: • 12,5 mm fermacell med 25 mm brandbatts • 50 mm kalciumsilikat paneler Det ska byggas in konvektionshål över och under kaminen. uppbyggnad av bakre vägg och snedställd plåt...
  • Seite 289 Svensk RAIS/ - Bruksanvisning til VISIO VISIO 3 - monteringsavstånd - paneler avstånd från sidoglas till avstånd från sidoglas till brännbart material min. brännbart material min. 220 mm (t.ex. dörrkarm) 220 mm (t.ex. dörrkarm) möbleringsavstånd från möbleringsavstånd från sidoglas min. 750 mm sidoglas min.
  • Seite 290 Svensk RAIS/ - Bruksanvisning til VISIO VISIO 3 - monteringsavstånd - paneler ObS! Isolerad skorsten (medföljer ej) ända ner till adapter för rökutgång fri höjd över brännkammare min. 698 mm konvektionshål placeras direkt under den snedställda plåten för att rikta den varma luften ut genom monterade konvek- Reflektorplåt...
  • Seite 291 Svensk RAIS/ - Bruksanvisning til VISIO tegel - VISIO 3 Om man bygger in konvektionshål över och under kaminen, kan avstånden till brännbart överföras från de monterade panelerna til VISIO 3. Om man inte lyckas skapa tillräcklig konvektion kan det uppstå skador på väggar av tegel.
  • Seite 292 Svensk RAIS/ - Bruksanvisning til VISIO VISIO 3 - monteringsavstånd- tegel avstånd från sidoglas till bränn- avstånd från sidoglas till bränn- bart material min. 220 mm (t.ex. bart material min. 220 mm (t.ex. dörrkarm) - gäller endast vid kon- dörrkarm) - gäller endast vid kon-...
  • Seite 293 Svensk RAIS/ - Bruksanvisning til VISIO VISIO 3 - monteringsavstånd - tegel fri höjd över brännkammare min. 698 mm eventuella konvektionshål placeras direkt under den snedställda plåten för att rikta den varma luften ut genom monterade konvek- tionsgaller måste man montera Reflektorplåt...
  • Seite 294: Air-System

    Svensk RAIS/ - Bruksanvisning til VISIO air-system Vid montering av air-system säkerställer man att luftjusteringssystemet hämtar frisk luft utifrån. för att säkerställa att air-systemet fungerar måste man byggnadsmässigt se till så att det inte kan uppstå undertryck i bostaden.
  • Seite 295: Bränsle

    Svensk RAIS/ - Bruksanvisning til VISIO bränsle kaminen är testad i enlighet med en13240:2001, en13240:2001/a2:2004 och nS 3058/3059 för förbränning av kluven, torr björkved samt godkänd för lövträd/barrträd. Veden ska ha en fuktighet av 15–20 % och en maxlängd på 30 cm.
  • Seite 296: Torkning Och Förvaring

    Svensk RAIS/ - Bruksanvisning til VISIO torkning och förvaring Ved behöver tid för att torka. en korrekt lufttorkning tar ca 2 år. här är några tips: • förvara virket kapat, kluvet och staplat på en luftig och solig plats med skydd mot regn (sydsidan på...
  • Seite 297: Ventilation

    Svensk RAIS/ - Bruksanvisning til VISIO Ventilation Det får inte finnas ventilationsanläggning/fläkt (kök) i samma rum som kaminen då detta kan bidra till att kaminen avger rökgaser i rummet. kaminen behöver konstant och tillräcklig lufttillförsel för att fungera på ett säkert och ef- fektivt sätt.
  • Seite 298: Första Upptändningen

    Svensk RAIS/ - Bruksanvisning til VISIO första upptändningen Det lönar sig att börja försiktigt. börja med en liten brasa så att kaminen får vänja sig vid den höga temperaturen. Detta ger en bra inkörning och du undviker att skada kaminen.
  • Seite 299 Svensk RAIS/ - Bruksanvisning til VISIO • tänd brasan. • placera spjället i position 3 (i ca. 15 min.), därefter i position 2. • Stäng luckan helt och lyft i luckans handtag (luftspalt på 1-2 cm). • när elden brinner ordentligt i tändveden stängs luckan helt (efter ca.
  • Seite 300: Kontroll

    Svensk RAIS/ - Bruksanvisning til VISIO • Vid behov placeras spjällets handtag i position 3 (helt mot höger) i 2-5 min för att få fart på elden. • Därefter placeras spjället mellan position 1 och position 2 (se ”Inställning av spjället”).
  • Seite 301 Advarsel Advarsel Advarsel attika Svensk RAIS/ - Bruksanvisning til VISIO Hvis brændet kun ulmer eller ryger, og der tilføres for lidt luft, udvikles der Hvis brændet kun ulmer eller ryger, og der tilføres for lidt luft, udvikles der Hvis brændet kun ulmer eller ryger, og der tilføres for lidt luft, udvikles der VARNING!! uforbrændte røggasser.
  • Seite 302: Rengjøring Och Skötsel

    Svensk RAIS/ - Bruksanvisning til VISIO Rengjøring och skötsel peisovn og skorstein skal kontrolleres av en feier én gang i året. Ved rengjøring og skötsel skal ovnen være kald. Om glasset er tilsotet: • Rengör glaset regelbundet och endast när det är kallt, annars bränner soten sig fast.
  • Seite 303: Rengöring Av Luckans Glas - Visio 2

    Svensk RAIS/ - Bruksanvisning til VISIO Rengöring av luckans glas - VISIO 2 luckan låses innan rengöring. med specialnyckeln (levereras med kaminen) vrids låsen (2 st.) över glaset utåt. frontglaset frigörs genom att vrida beslaget över och under glaset utåt.
  • Seite 304: Rengöring Av Luckans Glas - Visio 3

    Svensk RAIS/ - Bruksanvisning til VISIO Rengöring av luckans glas - VISIO 3 luckan låses innan rengöring. med specialnyckeln (levereras med kaminen) vrids låsen (1 st. per sida) över glaset utåt. Sidoglaset frigörs genom att vrida beslaget över och under glaset utåt.
  • Seite 305: Rengjøring Av Brennkammer

    Svensk RAIS/ - Bruksanvisning til VISIO Rengjøring av brennkammer askan skrapas/skyfflas ner i gallret mitt i kaminen. asklådan under kaminen kan tas ut och tömmas i en icke brännbar behållare tills askan har svalnat. kald aske kan kastes sammen med vanlig husholdningsavfall.
  • Seite 306: Driftstörningar

    Svensk RAIS/ - Bruksanvisning til VISIO baffelplåten vilar på 2 kanaler - skjut den framåt, tippa och sänk den, därefter kan den lyftas ut. stift stift ta bort smuts och damm och sätta när baffelplåten monteras sätts delarna i omvänd ordning.
  • Seite 307 Svensk RAIS/ - Bruksanvisning til VISIO Om förbränningen i kaminen är för stark kan bero på • otätheter vid luckans packning • draget i skorstenen är för stort > 22 pa, regleringsspjäll bör monteras Om förbränningen i kaminen är för svag kan bero på...
  • Seite 308: Tillbehör Visio 2 - Visio 3

    Svensk RAIS/ - Bruksanvisning til VISIO tillbehör VISIO 2 - VISIO 3 frontbeklädnad til VISIO 2 frontbeklädnad til VISIO 2 6-sidig - vänster - 6 mm tjocklek 6-sidig - højre - 6 mm tjocklek 124142080 - rostfritt 124143080 - rostfritt...
  • Seite 309 Svensk RAIS/ - Bruksanvisning til VISIO konvektionsgaller - front konvektionsgaller - side 511480470 - vit 836480470 - vit 511480490 - svart 836480490 - svart 511480870 - vit 836480870 - vit 511480890 - svart 836480890 - svart 836480470 511480470 836480490...
  • Seite 310: Reservedelar Visio 2

    Svensk RAIS/ - Bruksanvisning til VISIO Reservedelar VISIO 2 pos. antall Varenr. beskrivning handtag för luftspjäll - komplet 1240905mon luftspjäll - komplet 1240990 handtag til lucka 1241015mon kall handtag - komplet 1242410 glaslistor - målat VISIO 2l (vänster) 124205090 glaslistor - rostfritt Visio 2l (vänster)
  • Seite 311: Prestandadeklaration

    prestandadeklaration...
  • Seite 313: Attika Feuer Ag

    ATTIKA FEUER AG Brunnmatt 16 CH-6330 Cham Switzerland www.attika.ch RAIS A/S Industrivej 20 DK-9900 Frederikshavn Denmark www.rais.com...

Diese Anleitung auch für:

V i s i o 3

Inhaltsverzeichnis