Horizontal wall terminal, type C11

Dimensions of flue pipe:
The fireplace is supplied with an outlet spigot Ø100/Ø150 mm or Ø130/Ø200 mm, depending on the
model. This flue dimension can be used for the entire flue. Alternatively, a Ø130/Ø200 adapter can be
fitted, so that this flue dimension can be used for the rest of the flue.
Flue terminal:
Ø130 / Ø200 Item no. USDHC 130
Ø100 / Ø150 Item no. USDHC 100
Maximum length of flue pipe to outer wall (H)
= 3 X vertical flue pipe length (V) -1 for Ø130 / Ø200 pipe.
= 2 X vertical flue pipe length (V) for Ø100 / Ø150 pipe.
Maximum permitted length (V + H) = 15 m.
Minimum vertical height of flue pipe for Visio Gas = 0.5 m.
Visio 3, 4, 6 and 7:
Vertical length
Maximum length
of flue pipe (V) in
of horizontal flue
metres
pipe (H) in metres
Ø130/Ø200
0.5
1.5
1
3
1.5
4.5
2
6
2.5
7.5
3
9
3.5
10.5
4
11
4.5
10.5
5
10
5.5
9.5
6.5
8.5
7
8
7.5 <
7.5
INSTALLATION MANUAL
Maximum length
of horizontal flue
pipe (H) in metres
Ø100/Ø150
1
2
3
4
5
6
7
8
9
10
9.5
8.5
8
7.5
Visio 5:
Vertical length
Maximum length
of flue pipe (V)
of horizontal flue
in metres
pipe (H) in metres
Ø130/Ø200
1
2
2
4
3
6
4
8
5
10
6
9
7
8
8
7
GB - 18