Herunterladen Inhalt Inhalt Diese Seite drucken

attika VISIO GAS serie Installationsanleitung Seite 68

Inhaltsverzeichnis

Werbung

Visio 43/49/65 RD - Visio 43/49/65 T
Gas type
(Natural gas - LNG)
Supply Pressure
Nominal Heat Input
Gross (Hs)
Nominal Heat Input
Net (Hi)
Consumption
Burner Pressure
(hot)
Injector Marking
Pilot
Efficiency Class
NOx Class
Type
Gas type
(Town gas)
Supply Pressure
Nominal Heat Input
Gross (Hs)
Nominal Heat Input
Net (Hi)
Consumption
Burner Pressure
(hot)
Injector Marking
Pilot
Efficiency Class
NOx Class
Type
67 - GB
INSTALLATION MANUAL
G20
I2H, I2E
mbar
20
kW
14.5
kW
13.1
m³/hr
1.36
mbar
18.2
220 Centre, 360 Left, 360 Right
G30-ZP2-312 (31.2 inj)
1
5
C11 / C31
G150.1
mbar
8
kW
10.2
kW
9.1
m³/hr
1.800
mbar
3.5
480 Centre, 1400 Left, 1400 Right
G150.1 CG (inj. 27.1 - 90)
1
5
C11 / C31
G20/G25
G25/G25.3
I2E+
I2L / I2EK
I2(43.46 -45.3 MJ/
m3 (0°C))
20/25
25
14.5 / 13.3
13.3
13.1 / 11.9
11.9
1.36 / 1.45
1.45
18.2 / 21.5
21.6
G20/G25
I2ELL
20
12.0
9.0
1.35
18.2

Quicklinks ausblenden: