8 Technical data

Voltage
Built-in batteries
External batteries / adapter
Current
Built-in batteries
External batteries 12 V/ adapter : Display 'ON' 95 mA
External batteries 24 V
Temperature
Operating temperature range
Storage temperature range
Pressure sensor
Indicating range
Linearity of indication
(with reference to sea-level)
Temperature stability
Time accuracy
Baroscope
: 2 V to 6.3 V/DC
: 10 V to 30 V/DC
: Display 'ON' 98 mA
Display 'OFF' 0,064 mA
Display 'OFF' 21 mA
: Display 'ON' 55 mA
Display 'OFF' 8 mA
: 0˚C ... +40˚C
: -20˚C ... +60˚C
: 950 hPa - 1070 hPa
: +/- 1 hPa
: +/- 2 hPa (0˚C ... +40˚C)
: +/- 4 secs. per month
Display and curve plotting
Active viewing area on
display panel
Graphic resolution of display
Timescale
Pressure-scale window
(segment overall range)
Resolution of pressure curve
Pressure resolution in
digital display
Weight
Dimensions (W x H x D)
ENGLISH
: 92 x 74 mm
: 160 x 128 pixel
: 24 hours or 1 week
: 20 hPa over 24 hours
120 hPa over 1 week
: 0.2 hPa per pixel
: 0.1 hPa
: 0.5 kg
: 155 x 135 x 81 mm
Note: 1 hPa = 1 mbar