76
10
DATA SHEET
10.1
TYPE
CLEAR SOFT Water softener
10.2
TECHNICAL SPECIFICATIONS
/
The water to be softened must conform to the European drinking water regulations!
/
The nominal pressure denotes the pressure class, to which the water softener must fulfil. The maxi-
mum operating pressure is lower, in order to ensure the optimum function of the water softener.
Technical specification
Connection diameter nominal
Nominal capacity
Capacity per kg regenerating salt
Volume of exchanger resin
Nominal pressure
Operating pressure
Flow pressure at nominal flow rate
Pressure loss at nominal flow rate
Nominal flow rate
Short-term flow
Water consumption per regeneration
Electrical connection
Power consumption: Operation
Water and ambient temperature
Operating weight when filled with salt
Salt container capacity
Shipping weight
For further information, please refer to the chapter 10.3 "DIAGRAMS".
Regeneration
CLEAR SOFT
DN 25 / 1"
0.45 mol
5 mol
approx. 2.5 l
PN 10
2 - 7 bar
min. 2 bar
1 bar
1,2 m³/h
max. 3,5 m³/h
approx. 12.5 l
230 V / 50 Hz
2 W
max. 15 W
max. 30 °C
approx. 45 kg
25 kg
approx. 23 kg