ELECTRICITY SUPPLY

A splash proof socket is required for the power supply, in accordance with the le-
gal regulations for wet rooms!
The mains voltage may not be interrupted (e.g. by light switches)!
If the water softener is not permanently supplied with power,
/
no regeneration takes place,
/
no alarm is given in case of faults,
/
water losses or even water damage can occur, if there is an interruption during regeneration.
5.4

MOUNTING THE BUILT-IN ROTARY FLANGE (JQE)

Install using the supplied built-in rotary flange. The built-in rotary flange is used as a connecting element
between the pipe and the water softener. It is suitable for both horizontal and vertical pipes. The installa-
tion height depends on the pipe layout.
The built-in rotary flange must be installed in the direction of flow. This is marked by a
cast in arrow (see fig. 3).
Failure to comply with this means the water softener cannot work.
The built-in rotary flange must be fitted so that mechanical stresses cannot occur!
Otherwise mechanical damage can result, the pipe may burst or the built-in rotary flange can break. This
can result in major water damage. In this case, persons close to the water softener are exposed to a health
risk due to the large quantities of water.
Therefore, during installation, ensure that no large forces act on the pipe, built-in rotary flange and water
softener.
Profiled flange gasket
Fig. 3: Built-in rotary flange
Flow direction arrow