Caution!
Beware of hot water splashing while cleaning the group.
Empty the water drip tray regularly and do not wait until it is full in case the machine is not directly hooked up
to a water drainage.

7.3 Maintenance

Vorsicht!
Make sure that the machine is disconnected from the power supply during maintenance and
when replacing parts.
Replacing the group gasket and the shower screen
Switch off the machine, disconnect the power cord and let the machine cool down.
Follow the steps as indicated below:
1
Brew group in the beginning,
lower
view.
4
Remove the shower screen and
the gasket completely.
7
Insert the shower screen into the
brew group.
Translation of the German original user manual
2
Use a flat screwdriver to pry out
the shower screen and the group
gasket.
5
Keep the new spare parts ready at
hand (the rounded side of the
group gasket with ECM print
faced upwards to the brewing
group).
8
Take the portafilter without filter.
3
The shower screen and the
gasket are now nearly removed.
6
Clean the group with a brush.
Lock the shower screen firmly
into the gasket.
9
Clamp the portafilter into the
brew group.