Ensure that the equipment is not
hung up or held by the mains
cable. There is a risk of electric
shock from damaged mains ca-
bles.
Note that, over time, dirt and sand
may collect on the bottom of the
shaft, which could damage the
pump. If the water level is too low,
the silt in the shaft can quickly dry
out and impede the pump when
warming up.

Operational start-up

Check that the float switch is
working (see chapter: "Opera-
tion – Automatic mode").
Check that the pump is resting
on the pit base
Check that the pressure line has
been attached properly
Check the proper status of the
electrical plug socket and make
sure that the plug socket is suf-
ficiently fused (at least 6 A). In-
sert the pump plug into the plug
socket and the pump is ready
for operation.
Make sure that moisture or wa-
ter never come in contact with
the mains connection.There is a
risk of electrocution.

Operation

Mains connection

The immersion pump acquired by you is
already provided with an grounded plug.
The pump is designed for connection to
an grounded socket with 230V ~50Hz.
10
Only start to operate the device
after all the above conditions have
been observed.

Switching on and off

1. Insert the plug in the socket. The
pump starts working immediately.
2. To switch off, withdraw the plug from
the socket. The pump stops.
If the water level is too low, the
float switch will automatically
switch off the pump.
Supervise the appliance while it is
in operation in order to be immedi-
ately aware if the automatic cut-out
operates or the pump runs dry, to
limit any damage to a minimum.

Automatic mode

In automatic mode, the float switch auto-
matically switches the pump on or off.
In the case of stationary installa-
tion, check regularly (no less then
once every three months) that the
float switch (10) is working.
The On/Off switch point of the float switch
(6) is infinitely variable:
Loosen the screw in the float
switch height adjustment (5) and
move it to the desired position.
Check the float switch (6).
-
It must be positioned so that
it can lift and lower freely. The
switching point heights "On" and
"Off" must be easy to reach.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis