  • DEUTSCH, seite 18
we recommend you contact your water supply com-
pany and/or your plumber.
I
For indoor installation, it is necessary to remember that water
evaporation from the spa (especially where high temperatures are
involved) can cause very high levels of humidity. Natural or forced
ventilation helps to maintain personal comfort and reduce damage
to the building due to humidity.
Jacuzzi Europe refuses all responsibility for any damage caused
by excessive humidity or by overflowing water. Consult a spe-
cialist for indoor installation.
I
Remember that it is compulsory to install a multiple-pole section
switch with characteristics that are not less than the ones given in
the chapter "Electrical safety" and
I
The installer must use cables with an adequate cross-section,
protected by a sheath and/or with tubes or ducts, with character-
istics not inferior to type H 05 VV-F.
The entry of cables into the mini-pool up to the electrical box (
2) must be provided at point B.
Note: The cross-sections of the leads must take account
not only the system absorption but also the cable path
and the distances, the chosen protection systems and
current specific regulations for fixed electrical systems in
the country where the spa is installed.
I
The installer must comply with the above regulations, and also
use watertight connectors at connection points. He must
also guarantee compliance with the specific current stan-
dards for systems in the country in which the spa is
installed.
It is mandatory to comply with this instruction. Any other proce-
dure is prohibited.

Electrical safety

The Premium spas are safe products, manufactured in compli-
ance with standards 60335-1: 2002, 60335-2-60: 2003,
60825-1: 1994+A1+A2, EN 55014-2, CISPR 22 CLASS B,
EN 61000-3-2, EN 6100-3-3 and tested during production to
user safety.
ensure
I
Installation must be carried out
sonnel , in compliance with current national provisions.
It is the responsibility of the installer to select mate-
rials based on their intended use, to carry out work
properly, to check the condition of the system that
the unit will be connected to and that it ensures safe-
ty of use also concerning maintenance work and the
possibility to examine the system.
I
The Premium spas "I" appliances and therefore they must be
permanently connected, without any intermediate connec-
tions, to the electrical system and to the protection system (earth
system).
i
2.
by qualified and authorized per-
The electrical system of the building must be pro-
vided with a 0.03A differential switch and with an
efficient protection (earth) circuit.
Check for proper operation of the differential switch
by pressing the TEST button, which should trip.
Parts incorporating electrical components, except
remote control devices, must be located or fixed so
that they cannot fall into the spa.
Live components and equipment must be out of
reach of individuals in the spa.
I
For electrical connections, the installation of a multiple-pole sec-
tion switch is compulsory (
that complies with safety regulations and, in any case, which can-
not be reached by those using the spa.
It is mandatory to comply with this instruction. Any other proce-
dure is prohibited.
i
I
The disconnection devices must be installed in the power sup-
ply network according to the installation instructions.
I
The installation of electrical devices and equipment (sockets,
switches, etc.) near the spa must be in compliance with legal stan-
dards and regulations in the country where the spa is installed.
I
For the equipotential connection as required by specific nation-
al standards, the installer must use the terminal provided (standard
EN 60335.2.60)in the electrical box (
symbol
.
In particular, an equipotential condition must be established for all
metallic masses surrounding the spa, for example water and gas
pipes, metallic platforms, and so on.
15
i
2). It must be positioned in a place
i
2), and marked with the