tools and it must be protected from water and bad weather
(see note "Spa-Pak and the balance tank" in the previous chapter).
For perfect operation of the system, the Spa-Pak must be installed at
the same level as the balance tank (
ence.
I
The balance tank
When possible, it must be installed near the Hot tub for optimum effi-
ciency (excess water will fall into the balance tank).
For correct operation of the balance tank, comply with the
dimensions provided in the respective tables
If the balance tank is installed outside, a suitable system
must be provided to protect it against the sun's rays and
ultraviolet radiation, to prevent damaging the container.

Electrical safety

The spas of the Experience range are safe products, manufactured in
compliance with standards EN 60335.2.60, EN 61000, EN 55014 and
tested during production to ensure their safety.
I
Installation must be carried out by qualified and authorized personnel,
in compliance with the national provisions in force.
It is the responsibility of the installer to choose the mate-
rials in relation to their use, to carry the work out cor-
rectly, to check the condition of the system to which the
appliance is to be connected and its suitability and to
guarantee safety when in use, regarding maintenance
operations and inspection of the system.
I
The spas of the Experience range are class "1" appliances and
therefore they must be permanently connected, without any inter-
mediate connections, to the electrical system and to the protection
system (earth system).
The appliance must be powered by a differential cir-
cuit breaker; the operating current must not exceed
30mA.
Check that the differential switch is working correctly by
pressing the test button (TEST), which must click.
Parts incorporating electrical components, except
remote control devices, must be located or fixed
so that they cannot fall into the spa.
Live components and equipment must be out of
reach of individuals in the spa.
I
For connection to the mains, it is necessary to install a discon-
necting multiple-pole switch that provides full disconnection under
overvoltage category III conditions (
a place that complies with safety regulations and, in any case, which
cannot be reached by those using the spa.
Compliance with this regulation is obligatory: any other procedure is
prohibited.
If the building's electrical system is not able to gua-
rantee a stabile power supply, it is recommended
i
6) or with a minimal differ-
i
(
7).
i
3-4). It must be positioned in
to install a voltage stabiliser that suitably dimen-
sioned for the required power upstream of the e-
quipment.
I
The disconnection devices must be installed in the power supply
network according to the installation instructions.
I
The installation of electrical devices and equipment (sockets, switch-
es, etc.) near the spa must be in compliance with legal standards and
regulations in the country where the spa is installed.
I
For the purpose of equipotential connection in compliance with spe-
cific national regulations, the installer must use the provided terminal
(EN 60335.2.60 standards) on the electric wiring box (
marked by the symbol
In particular, equipotential connection must be carried out for all metal
parts surrounding the mini-pool, for example, the water and gas pipes
and any surrounding metal under-frames etc.
I
The appliance comes equipped with an LED lighting system, in
compliance with Regulation EN 62471:2009.
CAUTION! Before carrying out any maintenance
operation, disconnect the appliance from the pow-
er supply line.
19
.
i
4), and