CONNECTIONS
PT100/Tcj-Tck (24Va, 115Va, 230Va)
OUT
ALL
1
2
3
4
5
6
Supply
1-2
N.O. regulator relay OUT
3-4
N.O. alarm relay ALL
*5-6
Power supply 24V
A
TTL input for Copy Card and TelevisSystem connection
MODELLO PT100/Tcj-Tck
Display range:
10 11 12
Analogue input
+
Serial
Digital outputs
Buzzer output
Measurement range
Accuracy
Resolution
TERMINALS
, 115V
and 230V
.
a
a
a
INPUT/OUTPUT CHARACTERISTICS
PT100: -150...650°C
TcJ: -40...750°C
TcK: -40...1350°C
on display with 3½ digits + sign
1 PT100 or 1 TcJ / Tck
(selectable by parameter H00)
TTL for connection to Copy Card or
Televis/Modbus remote control systems
OUT: 1 SPST relay 8(4)A 250 V
ALL: 1 SPST relay 8(4)A 250 V
only on models where this is provided
-150 ... 1350°C (-238 ... 2462°F)
see 'Pt100/TcJ/TcK models' table
see 'Pt100/TcJ/TcK models' table
*10-11-12 Probe PT100 input - 3 wires (Pb1)
*11-12
TcJ/TcK input
* depends on model