Herunterladen Inhalt Inhalt Diese Seite drucken

Comet KF Steel 12/100 Bedienungsanleitung Seite 26

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 71
Directive 97/23/EC for pressure equipment (PED). The compliance with this requirement is assured by
a special electronic device that constantly checks:
• that for temperatures above 110 °C/230 °F, the pressure set is below 32 bar/464 psi;
• that for pressures above 32 bar/464 psi, the temperature set is no greater than 110 °C/230 °F.
If the above limits are exceeded, the burner stops and the warning light (48) comes on.
Steam operation will only resume if the pressure is reduced to below 32 bar/464 psi.
• Turn the high pressure cleaner on again by turning the master switch (1) to
to below 32 bar/464 psi by turning the knob (8) anticlockwise.
• Set the temperature between 110°C/230°F and 140°C/284°F using the temperature adjustment
knob (25).
• Press the cleaner gun lever (24) and wait for steam to be produced.
• If the burner stops working during use of the cleaner and the warning light (32) lights up, turn the
knob (8) anticlockwise to lower the pressure below 32 bar/464 psi.
• You can check the pressure level on the pressure gauge (10).
• When the fuel is low, the burner will stop working and the warning light (28) will light up.
• The burner will only start working approximately 3 seconds after the cleaner gun has been opened
and will stop working when the cleaner gun is closed or when it reaches the set temperature.
• If the flame goes out, the burner will stop working and the warning light (33) will light up.
The Manufacturer recommends the use of detergents which are at least 90% biodegradable.
Refer to the label on the detergent for instructions on how to use it.
• Turn the master switch (1) to "0" .
• Put the hose (37) in the external tank (FIG. 5) which has already been prepared with detergent to the
strength required: in this case too, follow the instructions given for the dosage on the detergent pack
label.
• Turn the knob for adjusting the detergent (20) anticlockwise.
Switch the cleaner on again by turning the master switch (1) to
lever (24) to start distribution of detergent (these versions distribute the detergent at high pressure).
The KF STEEL models
preventing the build up of lime scale as a result of using the cleaner with hot water.
• Turn the master switch (1) to "0". Unscrew the cap (9) and fill the tank with liquid, making sure it does
not spill over. We recommend using a funnel reserved exclusively for this purpose (maximum tank
capacity 2 L/0.53 US gal). Replace the cap and check the level regularly.
Only use water softeners recommended by the Manufacturer.
• Release the cleaner gun lever (24) to stop the high pressure jet and the high pressure cleaner moves to
by-pass operating mode, and if it remains in this condition it will stop automatically after approximately
13 seconds (Total Stop).
• The cleaner will resume normal operation the as soon as the lever on the gun is pressed.
WARNING
• If you stop the high pressure jet and put the gun down, enable the locking handle (27). STEP K IN FIG. 4.
26
OPERATION WITH DETERGENT
OPERATION WITH WATER SOFTENER
of the product are fitted with a high-performance water softener as standard,
STOPPING THE CLEANER – TOTAL STOP MODE
and set the pressure
or
; operate the cleaner gun

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis