Herunterladen Inhalt Inhalt Diese Seite drucken

Control Descriptions - FIMAR TS1 Benutz Und Wartungsanleitun

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 63
HEAT SEALERS

CONTROL DESCRIPTIONS

The appliance is equipped with the listed con-
trol devices, required to run its main functions.
A1)Main switch: used to turn the appliance
on and off.
A2)Display: it shows warning/alarm messag-
es and working parameters.
A3)Indicator light: when on, the appliance is
electrically powered.
A4)Indicator light: if it is switched on it means
that the sealing plate has reached the set
temperature.
A5)Indicator light: if it is switched on it means that the appliance is in alarm conditions.
A6)Indicator light: if it is switched on it means that film sealing is in progress.
A7)Button: used to set the film sealing time.
A8)Button: used to set the film sealing temperature.
A9)Button: to increase the value of the selected parameter or to scroll the programmes.
A10)Button: to decrease the value of the selected parameter or to scroll the pro-
grammes.
A11)Button (RESET): used to display and set the work programs.
INSTRUCTIONS FOR USE
Work program selection
1. Press and hold the button (A11).
2. Select the program of interest using the buttons (A9-A10).
3. Release the button (A11) when the program of interest appears on the display.
Programming the work parameters
The procedure is used for programming the parameters of a new work program, overwriting
a pre-existing one which will be deleted.
1. Press and hold the button (A11).
2. Select the program to be overwritten using the buttons (A9-A10).
3. Press and hold the button (A7).
4. Set the sealing time using the buttons (A9-A10).
5. Release the button (A7) when the value of interest appears on the display.
6. Press and hold the button (A8).
7. Set the sealing temperature using the buttons (A9-A10).
8. Release the button (A8) when the value of interest appears on the display.
9. Release the button (A11) when the procedure is complete.
The parameters are stored in the new work program.
- 9 -
TS - TSA
English language
EN

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ts2Tsa1Tsa2Tsa3Tsavg

Inhaltsverzeichnis