18.7.
Inlet filter replacement
(Fig.15)
 Pull out the rubber plug (2) by hand.
 Remove the dirty inlet filter (1).
 Insert a new filter and replace the rubber plug.
18.8.
Filter element replacement
(Fig.16)
 Remove the hose (1) from the quick connector.
 Use a wrench (2) to release the filter vessel (3) and remove.
 Pull down on the filter element (4) to remove.
 Insert a new filter element.
 Re-install the filter vessel.
 Gently tighten the filter vessel with the wrench.
 Install the hose back on the quick connector.
1
Fig.16
18.9.

Filter element replacement in the KJF-1 unit

Before proceeding, vent the air tank to zero pressure and disconnect the equipment from
power.
(Fig.17)
Replace the filter inside the automatic condensate drain when
the condensate unit is in regular operation.
Release the catch (1) on the filter vessel by pulling
downward, rotate the filter cover (2) to the left and remove.
Unscrew the filter bracket (3) by turning it to the left.
Replace and secure the new filter by rotating the filter
bracket to the right back against the filter body.
Replace the filter cover and secure it by turning to the right
until the catch locks.
18.10. Cooler and fan check (Fig.3)
The equipment altogether, and especially the compressor fan, cooler fan (21) and cooler (14), must be kept
clean to ensure efficient drying performance; vacuum or blow down the cooling fins and fans with
compressed air to remove any dust from the surface.