OPERATION

THE EQUIPMENT MAY ONLY BE OPERATED BY THE TRAINED STAFF!

IN CASE OF EMERGENCY, DISCONNECT THE COMPRESSOR FROM THE MAINS

(PULL OUT THE MAINS PLUG).
THE AIR PUMP HAS HOT SURFACES.
BURNS OR FIRE MAY RESULT IF CONTACT IS MADE.
During prolonged operation of the compressor, the temperature in the cabinet may
increase to over 40°C. At this point the cooling fan automatically switches on. After
cooling the space to under 32°C, the fan switches off.
Automatic start: when pressure in the pressure tank decreases below the switch-on
pressure, the compressor automatically switches on. The compressor automatically
switches off when pressure in the air tank reaches the switch-off pressure.
The working pressure settings for the pressure switch set by the manufacturer
cannot be changed. Compressor operation at a working pressure below the switch-
on pressure indicates high air consumption (see the chapter Malfunctions)
Required drying performance can only be achieved when following the defined
operating conditions!
Drying performance will decline and the achieved dew point will drop if the dryer is
operated at any pressure below the minimum working pressure!
WHEN THE DRYER IS OPERATED AT AMBIENT TEMPERATURE THAT IS HIGHER
THAN MAXIMUM OPERATING TEMPERATURE, THE DRYER MAY BE DAMAGED!

COMMISSIONING

 Make sure all transport stabilizers were removed.
 Check that all pressurized air line connections are secure.
 Check to ensure power is connected correctly to the compressor.
 Check the position of the breaker switch; it should be in the "I" position; if the switch remains in
the "0" position, turn the breaker switch (4) to the "I" position. (Fig. 9)
 Check to see if the DK50-10S/M cabinet (8-10 bar models only) is connected to the compressor
using the cable with the connector. (Fig. 8)
 For DK50-10 S/M (8-10 bar) compressors, turn on the switch (5) on the front of the cabinet to the
"I" position and the green indicator indicates the operational status of the device. (Fig. 9)
The compressor is not equipped with a backup power supply.