TROUBLESHOOTING

Caution!
appliance from the mains.
For permanently high efficiency of drying, it is necessary to maintain the whole appliance, and
mainly ventilator clean – regularly clean the surface of ventilator and cooling fins of cooler.
Troubleshooting can be performed only by qualified personnel.
MALFUNCTIONS
Compressor does not
start
Compressor often
switches on
Low pressure in air
tank (compressor
running constantly)
Prolonged operation
of the compressor
Compressor is noisy
(knocking, metal
noises)
Dryer doesn't dry
(condensed water in
the air) *
)* After a dryer malfunction, the interior surfaces of the air tank must be thoroughly cleaned and all
condensed liquid removed.
Check the dew point of the air leaving the air tank (see Chapter 5 - Technical data) to protect the
equipment from damage!
NP-DK50-1_08-2017-MD
Before proceeding, depressurize the air tank to zero and disconnect the

POSSIBLE CAUSE

No voltage at the pressure switch
Motor winding failure, damaged
thermal overload protection
Faulty capacitor
Seized piston or other rotating part
Pressure switch does not switch
Air leak in compressed air distribution
system
Leaking check valve
Large volume of condensed liquid in
pressure vessel
Low compressor performance
High air usage by appliance, Leak in
compressed air system, Low aggregate
output
Aggregate malfunction
Dryer malfunction
Air leak in compressed air distribution
system
Worn piston ring
Inlet filter is plugged
Defective solenoid valve
Damaged piston bearing, piston rod,
motor bearing
Loose or cracked spring
Cooling fan not working
Damaged dryer
Non-functioning automatic condensate
drain - clean / replace on the filter
Check voltage in socket
Check the circuit breaker – switch into the
"I" on position
Loose conductor at terminal – tighten
Check the electrical cord – replace
defective cord
Replace motor or windings
Replace capacitor
Replace damaged parts
Check the function of the pressure switch
Check compressed air distribution
system – seal loose joints
Clean solenoid valve, replace seals,
replace solenoid valve
Drain condensed liquid
Check the time to fill the air tank
Check compressed air distribution
system – seal loose joint
Replace worn piston ring
Replace old filter with a new filter
Repair or change the valve or coil
Replace damaged bearing
Replace damaged spring
Replace the fan
Check the power source
Replace the dryer
Clean / replace