PRODUCT MAINTENANCE
To ensure that the compressor works correctly, perform the following maintenance tasks at regular
intervals.

16.2. Cleaning the product

Clean the product using regular detergents or an alcohol-based cleaner. The product cannot be
cleaned using any substances containing an abrasive substance, chemical solvents or other
aggressive substances.
16.3. Draining condensate from the vessel
During standard operation, the condensate is captured in the filter and subsequently automatically
released into the condensate vessel. Remove the vessel from its holder, loosen the cap and drain
the condensate at the defined intervals. Then close the vessel and place it back.
Risk of slipping on a wet floor in case of the collecting vessel overflow.
Monitor the level in the vessel using the markings and empty at least once a
day.

16.4. Replacement of filter element in filter

Disassemble the cabinet cover before replacing the filter element. The earthing cable must be
disconnected after partially removing the cabinet cover (See chap. 16.9).
Remove the hose (1) from the quick connector.
Use a wrench (2) to release the filter vessel (3) and remove.
Pull down on the filter element (4) to remove.
Insert a new filter element.
Re-install the filter vessel.
Gently tighten the filter vessel with the wrench.
Install the hose back on the quick connector
Connect the earthing cable to the cabinet cover and install the cabinet cover.