Memorizing the programming
It is OBLIGATORY to conclude the programming procedures with this function so as not to lose
any saved settings!
Press + to select 5.

Adjusting the sensitivity

The door must be properly balanced. If the sensitivity is too low it could cause the door to malfunction.
By default, the sensitivity is set to a medium level. To increase or reduce sensitivity:
1
2
3
4
5
6
 The last phase of programming must always be memorized (function 5).
Once memorization is complete, perform two opening and closing cycles to confi rm that the settings have
been saved.
Press P for about fi ve seconds, 1 appears.
Press + and select 4.
Press P, appears .
Press + o - to set the suitable sensitivity level.
Minimum level of Maximum sensitivity
Press P to save the procedure.
Press P. The display segments rotate clockwise.
The programming has been memorized.