Cable types and minimum thicknesses
Connection
Control panel power supply 230 V AC
Flashing light
Photocell transmitters
Photocell receivers
Command and safety device
Antenna
 If cable lengths differ from those specified in the table, establish the cable sections depending on the actual
power draw of the connected devices and according to the provisions of regulation CEI EN 60204-1.
For multiple, sequential loads along the same line, the dimensions on the table need to be recalculated according
to the actual power draw and distances. For connecting products that are not contemplated in this manual, see
the literature accompanying said products
Standard installation
1. Operator with receiver
2. Slide guide
3. Release device
4. Transmission arm
5. Key-switch selector
6. Photocells
7. Keypad
8. Sensitive safety-edge
5
Cable type
50267-2-1
RX
6
Cable length
1 < 15 m
H05VV-F
3G x 1.5 mm
FROR CEI
20-22
CEI EN
RG58
4
7
6
TX
8
Cable length
15 < 30 m
2
3G x 2.5 mm
2
2 x 0.5 mm
2
2 x 0.5 mm
2
4 x 0.5 mm
2
2 x 0.5 mm
max 10 m
2
3
2
1