Connecting The Power Supply - STIEBEL ELTRON DEM series Bedienung Und Installation

Mini-durchlauferhitzer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

.CZ`<<`.HC
.CZ`<<`.HC
Damage to the appliance and environment
f When making any connections, counterhold them on
the appliance using a size 14 spanner (see chapter
"Installation options / Undersink installation").
Appliance installation
f Install the appliance with the water connections onto the tap.

10.3 Connecting the power supply

DANGER Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
DANGER Electrocution
f Ensure that the appliance is earthed.
The appliance must be able to be separated from the
power supply by an isolator that disconnects all poles
with at least 3 mm contact separation.
Damage to the appliance and environment
Observe the type plate. The specified voltage must match
the mains voltage.
qqq Z`. <é<`VHC HB
DANGER Electrocution
Appliance DEM 3
In its delivered condition, the appliance is designed for
unpressurised water connection and equipped with a
power cable including plug.
Provide a permanent connection if the appliance is to be
used under pressure-tested conditions.
f Remove the plug from the power cable and prepare
the cable for a permanent power supply.
f Connect the power cable in accordance with
the electrical connection diagram (see chapter
"Specification / Wiring diagram").
f Change the type plate. Cross out "0 MPa" and tick
"1 MPa". Please use a ballpoint pen to do this.
DANGER Electrocution
Appliances DEM 4 and DEM 6
In its delivered condition, these appliances are equipped
with a power cable for a permanent power supply.
You can connect a cable with a maximum cross-section of
2
3 x 6 mm
inside the appliance if you decide in favour of a
direct connection to a permanently installed power cable.
f Connect the power cable in accordance with
the electrical connection diagram (see chapter
"Specification / Wiring diagram").