Herunterladen Inhalt Inhalt Diese Seite drucken

Opening The Appliance; Installing The Flanged Immersion Heater; Checking The Protective Anode; Descaling The Appliance - STIEBEL ELTRON ESH 10 U-P Plus Bedienung Und Installation

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
INSTALLATION
Maintenance

13.2 Opening the appliance

f Pull off the temperature selector.
f
f Remove the screws from underneath the temperature
f
selector.
f Open the appliance cover by lowering the bolt screws in-
f
wards and pivot the cover upwards, then remove it.

13.3 Installing the flanged immersion heater

Torque value of the flange screws

13.4 Checking the protective anode

f Check the protective anode for the first time 8 years after
f
installation. This requires removal of the flanged immersion
heater. Replace the protective anode if consumed.
f Decide the intervals in which further checks should be car-
f
ried out.
13.4.1 Fitting the protective anode
f To include the steel cylinder in the equipotential bonding,
f
observe the order of the fixing elements when fitting the
protective anode.
18
| ESH 10 U-P Plus | ESH 10 O-P Plus
Nm

13.5 Descaling the appliance

Material losses
!
Never treat the protective anode with descaling agents.
f Remove the flanged immersion heater.
f
f Carefully tap the heating element to remove coarse limescale
f
deposits.
f Immerse the heating element up to the flange plate in desca-
f
ling agent.

13.6 Checking the earth conductor

f Check the earth conductor (in Germany DGUV V3 for exam-
f
ple) across a water connector and the earth conductor con-
tact of the power cable.

13.7 Replacing the power cable

The power cable must only be replaced by a qualified contractor
with an original spare part.
Note
Never remove the plastic thread holding the profile plate.
13.8 Positioning the temperature sensor in its
protective pipe
f When replacing the temperature controller and the high limit
f
safety cut-out, guide the temperature sensors into the pro-
tective pipe.
6±1
L1
Temperature controller
L2
High limit safety cut-out
ESH 10 U-P Plus
ESH 10 O-P Plus
L2
L1
L1
L2
160
180
250
160
www.stiebel-eltron.com

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Esh 10 o-p plus

Inhaltsverzeichnis