Herunterladen Inhalt Inhalt Diese Seite drucken

Connecting The Power Supply; Commissioning; Taking The Appliance Out Of Use; Recommissioning - STIEBEL ELTRON SHU 10 SLi Bedienung Und Installation

Vorschau ausblenden Andere Handbücher für SHU 10 SLi:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
.CZ`<<`.HC
HBB.ZZ.HC.C&

10.3.7 Connecting the power supply

DANGER Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
You can connect the appliance power as follows:
ª The power cable is provided with a plug for a standard
safety socket. This socket must be freely accessible after the
appliance has been installed.
ª Where the appliance is to be connected permanently to the
AC power supply (appliance junction box), ensure that all
poles can be separated from the power supply with a contact
separation of at least 3 mm.
ª If required, you may connect the SH 15 SLi appliances directly
(permanently) to the mains power supply. For this, fit the
special accessory "Set"; see chapter "Special accessories".
Risk of damage!
!
Observe the type plate. The specified voltage must match
the mains voltage.
Earth conductor
Ensure that the appliance is earthed.

11. Commissioning

DANGER Electrocution
Commissioning must only be carried out by an authorised
contractor in accordance with safety regulations.
Boil dry risk.
!
The high limit safety cut-out responds if the order is
confused (first water, then power). In such cases, replace
the controller and reset the high limit safety cut-out by
pressing the reset button; see chapter "Troubleshooting /
Resetting the high limit safety cut-out".
ª Open the hot water tap or set the mono-lever mixer tap to
"hot" until the water that flows out is free of air bubbles.
ª Check the safety assembly. When cracked open, a full stream
of water must flow.
ª Insert the plug into the mains supply.
ª Select a temperature.
qqq Z`. <é<`VHC HB

12. Taking the appliance out of use

ª Isolate the appliance from the power supply by unplugging it.
ª Drain the appliance, see chapter "Maintenance / Draining the
appliance".

13. Recommissioning

See chapter "Commissioning".

14. Appliance handover

ª Explain the appliance function to users and familiarise them
with its operation.
ª Make users aware of potential dangers, especially the risk of
scalding.
ª Hand over these instructions.

15. Troubleshooting

%| ù
|
¼
The appliance fails to
There is no power.
deliver hot water.
High limit safety cut-
out has responded.
Water can only be
The jet controller in
drawn at a reduced
the tap is scaled up.
rate.
Loud boiling noises
The appliance is scaled
inside the appliance.
up.
Activate the high limit safety cut-out
ª Push the reset button.
á V¼ ¼®
Check the fuse / MCB in your
fuse box / distribution panel.
Remove the cause for this fault
and replace the temperature
controller. Reset the high limit
safety cut-out by pressing its
reset button.
Descale or replace the jet
controller.
Descale the appliance.
Z+e ’ Z+ ’