Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning & Maintenance - Parkside PHG-2000 Bedienungs- Und Sicherheitshinweise

Vorschau ausblenden Andere Handbücher für PHG-2000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 57
brushed off with a soft wire brush.
Set the temperature to 450°C
hook nozzle (fig. B2)
Shaping plastic tubes
Install the reflector nozzle.
To prevent a kink in the tube, fill it with sand
and close it on both sides. Heat
the tube with consistent side-to-side
motions.
Set the temperature to 450°C
flat reduction nozzle (fig. B3)
removing paint or varnish / cleaning off
adhesives
Install the flat reduction nozzle.
Soften the paint or varnish with hot air while
lifting it with the scraper. Long heat exposure
burns paint and varnish and
makes removal difficult. Keep the scraper
sharp and clean. Many adhesives (e.g.,
labels) are
softened by heat. Bonds can then be broken
or excess adhesive removed.
Set the temperature to 450°C
reduction nozzle (fig. B4)
Shrinking
Install the reduction nozzle.
Use the reduction nozzle to heat small
surfaces. The reduction nozzle's diameter is
20 mm. Heat the shrinkable tubing
consistently.
Set the temperature to 450°C
Soldering
For point soldering, install the reduction
nozzle.
When using flux free soldering compound,
put flux or soldering paste on the location
to be soldered. Depending on the material,
heat the solder location for 50–120
seconds. Add solder. The solder must melt
HAM6005 Ma-D # 0902-24.indd 9
Using the appliance / Cleaning & maintenance
at the work piece temperature. After the
soldering area has cooled, remove the flux.
Set the temperature to 600°C
Operation
Fig. A
You can work manually with this hot air gun
or you can put it in a vertical position.
Check if the mains switch is on position "0"
before you connect the apparatus;
• Keep the main lead always away from
the hot air stream and the mouth piece;
• Put the mains switch in position 'I or II' to
let your hot air gun operate:
"1" = 450 degrees, air flow 300 l/min.
"0" = Off
"2" = 600 degrees, air flow 500 l/min.
When the temperature is excess 600° C, the
heats switches it off automatically, however,
the heater continues to run. When the heater
has cooled to operating temperature, the
heater is switched on again.
Switching off:
Slide the switch to 0.
Tip: For best results, test all work first on an
inconspicuous part of the work piece.
4. Cleaning & MainTenanCe
Always disconnect the apparatus
before carrying out inspection or
cleaning. Never use water or other
liquids to clean the electrical parts
of the hot air gun.
Never use easy inflammable liquids for
cleaning the hot air gun, especially for
the mouthpiece.
GB
9
24-02-09 16:30:09

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis