Herunterladen Inhalt Inhalt Diese Seite drucken

Jump Starting - ULTIMATE SPEED ULG 12 A2 Originalbetriebsanleitug

Kfz-ladegerät mit starthilfefunktion
Vorschau ausblenden Andere Handbücher für ULG 12 A2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

  • DEUTSCH, seite 39
In this event, verify the connection clamps
are correctly connected to the battery and
7
the correct battery type is selected. If the display
is still continuously lit, the battery may be de-
fective.
Digital Display button
tween the digital display of voltage and charging
progress in percent (Battery %). Use this button to
switch between the following displays:
– Battery %: indicates the charging progress for
the connected battery in percent.
– Voltage: indicates the voltage of the connected
battery.
– Alternator %: output power in percent
Battery Type button
the battery type to be charged. You can choose from
battery types. The battery type must absolutely be
correctly selected before starting the charging pro-
cess:
– 12 V Regular: these batteries (lead-acid batteries)
are typically used in cars, lorries and motorcycles.
They have vent caps and are often labelled
"low-maintenance" or "maintenance-free". This
battery type is designed to quickly transfer en-
ergy (e.g. starting an engine). "Regular" batter-
ies should not be used for "Deep Cycle"
applications.
– 12 V Deep Cycle: These batteries are commonly
also labelled "Deep Cycle" or "Marine". This
type of battery is typically larger than other
battery types. It delivers less short-term energy
but transmit energy longer. These batteries with-
stand numerous discharge cycles.
– 12 V AGM / Gel: The AGM battery type is typi-
cally a good Deep Cycle battery. They provide
the best "life" when recharged before being
drained more than 50 %. When fully discharged
they withstand about 300 charging cycles. The
GEL battery type is similar to AGM. The charg-
ing voltage is lower than for other lead-acid
batteries. Using the wrong charger for a Gel
battery will result in a reduction in power or a
shorter life.
,
6
: Use to switch be-
1
: Use this button to set
2
– 6 V Regular: Select this mode for conventional
6 V batteries.
Charge Start button
between the following options
– Fast Charge: charges quickly (recommended in
low outdoor temperatures / winter)
– Normal Charge: normal charging process (nor-
mal speed)
– Start: briefly delivers 75 ampere to bridge a weak
or drained battery to jump start an engine
Attention: This mode can only be exited by unplug-
ging the mains plug
9

Jump starting

Always make all the connections
as described and in the correct order. The vehicle's
electronics may otherwise be damaged.
Proceed against the specifications at your own risk
and responsibility.
Attention: This function is not suitable for batteries
below 45 Ah. This function could damage batteries
below 45 Ah.
Diesel vehicles and large-volume engines in part re-
quire amperages above 75 A for jump starting.
Note: The charger features an analysis program
to protect the battery from damage (e.g. sulphation
or rapid voltage drops), particularly during jump
starting. The device will not switch on the jump
starter with severely drained or heavily stressed bat-
teries to protect the battery. During this process the
battery is already being charged with lower currents
(Charging lights up). The display continues to read
"0". In this event the jump start function cannot be
used. This will protect the battery from damage.
You should then first charge the battery. You may
also use the "Fast Charge" or "Normal Charge"
function for this purpose.
Connect the car charger's mains cable
power.
Connect the red connector clamp
positive battery terminal. (The positive terminal
is marked with a "+" symbol and a red mark.)
Operation
: Use this button to switch
3
.
9
to the
7
GB
to
11

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis