Operation

Disconnect all electrical leads
and devices from the generator before starting the
engine.
ATTENTION! When being used for the first
time, motor oil (15 W-40, approx. 0.6 l) and petrol
(unleaded normal petrol) must be put in.
Check the fuel level and the oil, and if necessary
top them up.
Make sure you have adequate ventilation.
Ensure that the spark cable is securely in the
spark plug.
Unplug any electric device connected to the
generator.

Adding oil / petrol

When using the unit for the first time, unscrew
the red oil filler plug
of engine oil (15 W–40). Use the oil funnel
when doing so.
Unscrew the petrol cap
conventional unleaded petrol. The capacity is
max. 15 L.

Start the engine

ATTENTION! When starting with the express
start
you can injure your hand with the sudden
13
kick back.
Wear protective gloves when starting.
Open the petrol tap
wards.
Put the on / off switch
Turn the choke lever
position).
Start the engine with the express start
sharply pulling the handle. If the engine has not
started pull the handle again.
Push the choke lever
has started (in the right position).
Note: The procedure described in this chapter
is suitable for cold and warm starting.
10 GB
and add approx. 0.6 L
8
and fill the tank with
1
by turning the tap down-
14
to the on position.
11
to I
I (in the left
12
by
13
back once the engine
12

To load the generator

Connect the device to the 230 V∼ socket
ATTENTION! This socket can be loaded con-
tinuously (S1) with 2600 W and short term (S2) for
a maximum of 2 minutes with 2800 W.
Note: Some electric devices (sabre saws, drills etc.)
can use more electricity when doing heavy duty tasks.

Storing the engine

Before putting away, let the generator run with-
out load so that the device can „cool down".
Turn the on / off switch
Close the petrol tap
Overload protection
2 x 230 V sockets
26
WARNING! This generator is fitted
with an overload protector.
This cuts off the sockets
load switch
the sockets
6
ATTENTION! If this happens reduce the
amount of electrical output which you are
extracting from the generator or remove
defective devices which are attached.
ATTENTION! Faulty overload switches
should only be replaced with identically
constructed overload switches with the
same performance data. Please use our
customer service department.
Cleaning, maintenance, stor-
age, transport and ordering
replacement parts
Before cleaning and maintenance work, turn off the
engine and pull the spark plug connector
the spark plug