Anschlüsse
Connection for potential equalisation on the
threaded bolt in the housing:
Internal potential equalisation connection
Group 1
Group 2
Group 3
Group 4
Group 5
Group 6
Group 7
Group 8
Important notes
l Check all cables for continuity, short circuits and ground
faults.
l When the data cables are correctly connected, the va‐
lues are: voltage between DH and DG and voltage bet‐
ween DL and DG approx. 2.5 V.
l Attention! The connection plan on the following page is
a standard connection plan. Please follow the deviations
in your project specific connection plan.
00 8802 52, 10/12 (Rev. 3.0)
D
Danger! Potential equalisation required.
Power supply unit UPS
(Order no. 77 3400 00)
Ferrite (order no. 00 0080 34)
Fault message output
l Potential-free output.
l Collective output.
l Contact load: max. 100 mA / 24 V.
l In case of a fault contact opens at the screw clamps.
Fault message output switches in case of:
l Disconnected or defective OSYnet bus user.
l Disconnected or defective RAN bus user.
l Interrupted power supply on the ward.
l Interrupted power supply at the OSY-ControlCenter.
l Interrupted OSYnet bus.
l OSY-ControlCenter does not boot-up.
Assignment for the 9 pole Sub-D connector:
l RxD = 2
l TxD = 3
l GND = 5
Verpackungsbeilagen 11/2017, Seite 83
Connections
2
2 x 2.5 mm
Data Group 1
Data Group 2
Data Group 3
Data Group 4
Data Group 5
Data Group 6
Data Group 7
Data Group 8
Speech Group 1
Speech Group 2
Speech Group 3
Speech Group 4
Speech Group 5
Speech Group 6
Speech Group 7
Speech Group 8
Don't connect, if telephone line 5, 6, 7 or 8 is used.
Otherwise use for: Speech Group 17 - 20.
Don't connect, if telephone line 1, 2, 3 or 4 is used.
Otherwise use for: Speech Group 21 - 24.
Telephone Line 1
Telephone Line 2
Telephone Line 3
Telephone Line 4
Telephone Line 5
Telephone Line 6
Telephone Line 7
Telephone Line 8
GB
Pre-connected
Network switch
pre-connected