Herunterladen Inhalt Inhalt Diese Seite drucken

Warnings For The Compressed Air Special Oil; Triggering Device; Actuating System; Additional Instructions For Fastener Driving Tools Operated By Compressed Air - Parkside PDT 40 E4 Bedienungs- Und Sicherheitshinweise Originalbetriebsanleitung

Druckluft-tacker
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 63
Warnings for the compressed air
special oil
May be fatal if swallowed and enters
airways. IF SWALLOWED: Immedia-
tely call a poison center or doctor/phy-
sician. Do NOT induce vomiting. Store
locked up. Avoid release to the environ-
ment. Content and packaging have to
be disposed of in accordance with local
national regulations.

Triggering device

This fastener driving tool is operated by actuating
the trigger using finger pressure. Some fastener dri-
ving tools are fitted with an additional safety yoke
which enables the driving operation to be carried out
only after the muzzle of the tool is pressed against a
workpiece. These tools are marked with an inverted
triangle (
) and may not be used unless fitted with
an effective trigger lock

Actuating system

RISK OF INJURY!
Do not use the device on scaffoldings
or ladders.
Fastener driving tools equipped with contact ac-
tuation must be marked with the symbol »Do not
use on scaffoldings, ladders« and must not be
used for specific applications for example: when
moving from one driving location to another in-
volves the use of scaffoldings, stairs, ladders, or
ladder- like constructions, e.g. roof laths, closing
boxes or crates,fitting transportation safety sys-
tems e.g. on vehicles and wagons.
A dditional instructions for fastener
driving tool operated by compres-
sed air
RISK OF INJURY!
Do not use the device if the trigger lock 10 is
damaged or has been removed. Otherwise
injuries may result.
10
GB/CY
.
10
When loosening the hose coupling, hold the
hose firmly in your hand to prevent injuries cau-
sed by a rebounding hose.
Be absolutely certain to use a ¼ threaded nipple
and a quick-release coupling for the compressed
air connection.
Never place your hands near the mouth when
the device is ready to operate. Otherwise injuries
may result.
Pay attention to damage. Check the device
for damage before bringing it into use. If the
device exhibits defects, it must not be operated
under any circumstances.
Do not use any pointed objects. Never insert
pointed and/ or metal objects into the inside of
the device.
Only connect the air-powered staple gun to lines
which are guaranteed not to exceed the maxi-
mum operating pressure by more than 10 %, e.g.
with a pressure control valve in the compressed
air line (pressure regulator) with downstream or
built-in pressure limiting valve.
When using the air-powered staple gun be sure
not to exceed the max. pressure.
Only operate the air-powered staple gun at the
pressure required for the respective operation to
prevent needlessly high noise levels, increased
wear and malfunctions this causes.
FIRE AND EXPLOSION HAZARD!
Never use hydrogen, oxygen, car-
bon dioxide or other bottled gasses
to power this tool as doing so may
result in an explosion and thus may
cause severe injuries.

Original accessories/tools

Use only the accessories and attachments
detailed in the operating instructions. The
use of fasteners or other accessories other than
those recommended in the operating instructions
could lead to you suffering an injury.

Werbung