7.4 Maintenance

(If you have any questions, please contact your specialised dealer.)
Replacing the group gasket and the shower screen:
Switch off the machine (power switch in lower position) and disconnect the power cord.
1
Open the steam valve and release the steam. Then close it again.
2
Let the machine cool down to room temperature.
Follow the steps as indicated below:
1
Brew group in the beginning.
4
Completely remove the shower
screen and the gasket.
7
Insert the shower screen into the
brew group.
Instruction manual Profitec Pro 500
2
Use a flat screwdriver to pry out
the shower screen and the group
gasket.
5
Keep the new spare parts ready
at hand (the rounded side of the
group gasket upwards into the
brew group).
8
Take the filter holder without filter.
20
3
The shower screen and the
gasket are now nearly removed.
6
Clean the brew group with a
brush.
Lock the shower screen firmly into
the gasket.
9
Clamp the filter holder into the
brew group.

Quicklinks ausblenden: