AIR FOR COMBUSTION

AIR FOR COMBUSTION
For the fi replace to work correctly, it is essential for the com-
For the fi replace to work correctly, it is essential for the com-
bustion air to be introduced into by means of a pipe which links
bustion air to be introduced into by means of a pipe which links
the external environment to one of the specifi c air intake vents
the external environment to one of the specifi c air intake vents
( ( A A ) fi tted on the sides (fi g. 6) and below (fi g. 7).
) fi tted on the sides (fi g. 6) and below (fi g. 7).
To hook up the said piping, a 10 cm connection must be ap-
To hook up the said piping, a 10 cm connection must be ap-
plied to the chosen vent (
plied to the chosen vent (10 10 - fi g. 8
The inner section of the piping be at least 125 cm
The inner section of the piping be at least 125 cm
whole length.
whole length.
The vents not used for the connection to the combustion air
The vents not used for the connection to the combustion air
input piping must be closed with the covers provided.
input piping must be closed with the covers provided.
If the volume of air for combustion is insuffi cient or the type
If the volume of air for combustion is insuffi cient or the type
of building in which the fi replace is installed is particularly
of building in which the fi replace is installed is particularly
airtight, a supplementary air vent must be used.
airtight, a supplementary air vent must be used.
Butterfl y valve
Butterfl y valve
The combustion air fl owing into the fi replace must be regulated
The combustion air fl owing into the fi replace must be regulated
by one of the butterfl y valves provided.
by one of the butterfl y valves provided.
If the butterfl y valve is not correctly fi tted (see page 24), the
If the butterfl y valve is not correctly fi tted (see page 24), the
fi replace cannot be used.
fi replace cannot be used.
The lever to adjust the butterfl y valve can be installed in the
The lever to adjust the butterfl y valve can be installed in the
most suitable position, under the edge of the hearth.
most suitable position, under the edge of the hearth.
Adjusting the butterfl y valve
Adjusting the butterfl y valve
• • "lighting"/max heating capacity position (fi g. 9):
"lighting"/max heating capacity position (fi g. 9):
air valve lever completed pulled out. To light the cold fi replace
air valve lever completed pulled out. To light the cold fi replace
and for maximum fi replace power
and for maximum fi replace power
• • "slow burning" position (fi g. 10):
"slow burning" position (fi g. 10):
air valve lever pushed in.
air valve lever pushed in.
All combustion air vents are closed.
All combustion air vents are closed.
Fig. 9
Fig. 10
THE TECHNOLOGY
- fi g. 8). ).
2 2
along its
along its
12
Fig. 6
Fig. 7
Fig. 8
- 19
-
hot air exit
vents
13
counterweight
inspection
A
combustion air
vents
A
A
10

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Side 50x50Side 2Side 3

Inhaltsverzeichnis