Herunterladen Inhalt Inhalt Diese Seite drucken

Energy Savings" Mode; Water Filtering; General Information - Jacuzzi Profile Montageanweisung

Vorschau ausblenden Andere Handbücher für Profile:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 54
• With limitation of electrical consumption
The blower is turned on in conjunction with one of the two hy-
dromassage pumps. After one minute, the pump is turned off and
the other one is turned on, also for one minute. After that, the
pumps and blowers are turned off. During this cycle, the heater
is turned off but it can be turned back on.
• With limitation of electrical consumption
The operating mode is the same, except that the heater stays on.
The pumps and the blower are turned on at preset intervals,
depending on the temperature:
- temperature between 12 and 15 ° C (54-59 °F):
every hour
- temperature between 9 and 12 ° C (48-54 °F):
every 30 minutes
- temperature between 6 and 9 ° C (42-48 °F):
every 15 minutes
- temperatures at or below 6 ° C (42 °F):
continuous
NOTES
- If the temperature of the compartment drops rapidly, the fre-
quency of activation increases.
- If it becomes necessary to turn on the anti-freeze protection
during the filtering or rapid filtering ("Instant Clear") cycles,
those cycles will be suspended and they will resume when the
anti-freeze cycle is complete.
- If this protection is active, the spotlight may still be turned on.

"Energy savings" mode

When this function is set, the electric heater is not turned on until
the water temperature drops at least 10 °C (18 °F) below the set
point.
Press the key "Econo"
Edx, where "x" indicates the duration in hours.
Use the keys "Up"
sired duration, from a minimum of 0 to a maximum of 24, which
means the function is always on.
Press the "Econo"
ue. You will then go to the start time (Es).
First set the hour and confirm with the "Econo" key. Then set
the minutes, and press the "Econo" key again to memorize the
set values and exit programming.
When the function is on, the display will shown the respective
symbol.
. The display shows the message
and/or "Down"
to insert the de-
key again to confirm the selected val-
NOTES
- If a function is turned on (except for the spotlights and/or the
time) when energy savings is present, energy savings is sus-
pended, and the symbol on the display flashes. It restarts au-
tomatically 40 minutes after the function that was started is
turned off.
- The minimum temperature that characterizes energy savings
mode may never be less than 15 °C (59 °F) (minimum main-
tenance temperature).
- If there is a power outage, the set data are stored in memo-
ry. However, when the power comes back on, the function
does not resume. Rather, it is turned on at the set start time.
In addition to the parameters "I1x" (temperature unit of
measure) and "I2x" (limitation of electrical energy con-
sumption), there is also parameter "I3x", the "x" default
value of which is 0. Do not change the setting, otherwise
the electric heater will be turned off.
I

WATER FILTERING

Water filtering is essential to keep the water clean and clear, and
to get rid of suspended particles. This cleaning is provided by the
filtering pump and the cartridge filter located under the overflow
channel (see the chapter on maintenance of the cartridge filter).
The Profile spa is also equipped with a special kind of filter-
ing called "Instant Clear". This is instantaneous filtering, which
differs from the normal cycle due to its brief, intense duration.

General Information

Filtering occurs during a cycle that is run every 12 hours. This
cycle consists of 2 phases. Depending on the configuration of
electrical consumption limitation (see related chapter), they are
divided as follows:
• Start
(with limitation of electrical consumption)
the hydromassage pumps are turned on for 1 minute each, one
at a time. In this phase, the blower runs continuously.
(with limitation of electrical consumption )
the hydromassage pumps and the blower are activated jointly for
1 minute.
• Continuation
This phase is the same for both configurations. In it, the filtering
pump and the ozonator run for the time remaining in the cycle.
31