Installing the Remote Mount Enhanced Control Head in a DIN Mount
Bracket
When and where to use: Follow these steps to install the Remote Mount Enhanced Control Head in a DIN Mount
Bracket.
Procedure:
1 Slide the Remote Mount Enhanced Control Head onto the DIN Mount Bracket until it snaps into place.
2 Tighten the screws at both sides of the DIN Mount Bracket.
Figure 9: Remote Mount Enhanced Control Head Installation with DIN Mount Bracket
1
1 and 2 – DIN Mount Bracket Kit (PMLN5093)
Inserting the Remote Mount Enhanced Control Head with the DIN
Mount Bracket into the DIN Frame
When and where to use: Follow these steps to insert the remote mount enhanced control head with the DIN mount
bracket.
Procedure:
1 Insert the mounting frame into the DIN Mount Bracket and retain it by bending back the relevant fixing tabs.
2 Use all six tabs, if necessary, to hold it in place.
Note:
The tabs are easily bent back by twisting a large flat-bladed screwdriver into the slot behind the tabs.
For a more secure installation, the top and rear of the frame should also be secured with screws.
The demount tool can be used as an aid to mounting as well as demounting.