42 | Radio Installation
Table 45: Associated Components for Remote Mount
Item
Description
1
Remote Mount Cable – 3 m, 5 m, 7 m, 10 m
2
Remote Head Enhanced or Data Expansion Head
Enhanced
Note:
Vehicle installations require attention to the effects of EMC and over long cable runs additional protection
may be required. Motorola has suitable suppression kits such as Part Number 01015001001 Toroid EMC
Suppression Kit.
Wind the Remote Mount Cable ten times around each toroid.
Place each toroid 30.0±2.5 cm respectively from the expansion head and the control head.
Winding at both ends reduces the effective cable length approximately by 0.8 m.
Fix the toroids firmly to a stable surface once the Remote Mount Cable is connected.
Installing the Remote Mount Enhanced Control Head onto the Remote
Mount Trunnion
When and where to use: Follow these steps to install the Remote Mount Enhanced Control Head onto the Remote
Mount Trunnion.
Procedure:
1 Slide the Remote Mount Enhanced Control Head onto the mounting trunnion until it snaps into place.
2 Tighten the screws at both sides of the trunnion. After a few turns, tilt the control head for an optimum view of the
display. Then, complete the tightening of the screws.
Figure 8: Remote Mount Enhanced Control Head Installation with Remote Mount Trunnion
1
31mm
1 and 2 – Remote Mount Trunnion Kit (PMLN4912)
Send Feedback
| | 68015000584-J
Part Number
RKN4077_, RKN4078_, RKN4079_,
PMKN4020_
PMLN4904_ or PMLN4908_
2
155+/-0,3mm
1