Explosion protection
Non-sparking, energy-limited "nA"
Dust, protection by enclosure "t"
Permissible ambient temperature
● For operation with or without HART
● For operation with PROFIBUS PA or
with FOUNDATION Fieldbus
At ≤ -10 °C (+14 °F), the display refresh rate of the display is limited. For basic devices with explosion protection: When
1)
using Iy module, only T4 is permissible.
7.2
Natural gas as actuator medium
See detailed operating instructions for technical data for natural gas as actuator medium.
7.3
SIPART PS2 with and without HART
7.3.1
Electrical data
Current input I
W
● Rated signal range
● Load voltage at 20 mA
● Test voltage
● Binary input BE1 (terminals
9/10; galvanically
connected to basic device)
2-wire connection (terminals 6/8)
6DR50.. and 6DR53.. Without HART
6DR51.. and 6DR52.. With HART
Current to maintain the
auxiliary power supply
Required load voltage U
(corresponds to Ω at 20 mA)
● Without HART (6DR50..)
Typical
Max.
38
Ex markings
Zone 2:
Zone 22:
IP66
Zones 1, 2 and 22
1)
T4: -30 ... +80 °C (-22 ... +176 °F)
T6: -30 ... +50 °C (-22 ... +122 °F)
Zone 1
1)
T4: -30 ... +80 °C (-22 ... +176 °F)
T6: -30 ... +50 °C (-22 ... +122 °F)
Zones 2 and 22
T4: -20 ... +75 °C (-4 ... +103 °F)
T6: -20 ... +50 °C (-4 ... +122 °F)
Basic device without
explosion protection
≤ 0.2 V (= 10 Ω)
B
6.36 V (= 318 Ω)
6.48 V (= 324 Ω)
II 3 G Ex nA IIC T6/T4 Gc
II 3 D Ex tb IIIC T100°C Dc
Basic device with
explosion protection
Ex d
0/4 ... 20 mA
≤ 0.2 V (= 10 Ω)
DC 840 V, 1 s
Suitable only for floating contact; max. contact load
< 5 μA with 3 V
6.36 V (= 318 Ω)
6.48 V (= 324 Ω)
FM:
NI, Class I, Division 2, ABCD
NI, Class I, Zone 2, IIC,T6/T4
CSA:
Class I, Division 2, ABCD
Class I, Zone 2, IIC
CSA:
Class II, Divison 1
Basic device with
explosion protection
Ex "ia"
≤ 1 V (= 50 Ω)
≥ 3,6 mA
7.8 V (= 390 Ω)
8.3 V (= 415 Ω)
Basic device with
explosion protection
Ex "ic", "nA", "t"
≤ 1 V (= 50 Ω)
7.8 V (= 390 Ω)
8.3 V (= 415 Ω)
SIPART PS2 (6DR5...)