Herunterladen Inhalt Inhalt Diese Seite drucken

Installation; Operation - Ingersoll-Rand 5 series Allgemeine Informationen

Druckluftbetriebene kolbenpumpe für schmierstoffe
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 10
periods of time.
Disconnect air line from pump when system sits idle for
AIR AND LUBE REQUIREMENTS
WARNING EXCESSIVE AIR PRESSURE. Can cause personal
injury, pump damage or property damage. Do not exceed
maximum inlet air pressure as stated on motor model
plate.
Filtered and oiled air will allow the pump to operate more ef-
fi ciently and yield a longer life to operating parts and mecha-
nisms.
Use an air regulator on the air supply to control the pump
cycle rate. This will help to prolong the life of the pump.
Supply the air lubricator with a good grade of SAE 90 wt. non-
detergent oil and set the lubricator to a rate not to exceed one
drop per minute.
TRANSPORT AND STORAGE
Store in a dry place, do not remove product from box during
storage.
Do not remove protection caps from inlet and outlet prior to

installation.

Do not drop or damage box, handle with care.
INSTALLATION
Remove protection caps from inlet and outlet of pump.
Exhaust silencer kits are available for these pumps. Mount
exhaust silencers or pipe exhaust away as required to a safe
location.
Install a ground wire to the air motor ground lug.
Connect fl uid hose to pump outlet. In most cases, a pipe seal-
ant should be used on thread connections. Tighten all fi t-
tings.
Mount the pump as required for the application. Many ap-
plications of lubrication pumps require direct mounting to
a standard container, drum cover or wall mounting. Miscel-
laneous accessories (hoses, fi ttings and control handles) are
included with the pump to complete an installation. Refer to
the illustration in the manual.
FLUSHING
NOTICE
Pumps have been tested with a petroleum based
fl uid. If necessary, fl ush the pump with a solvent compatible
with the material to be pumped.
1.
Turn air regulator pressure control knob to "0" pressure set-
ting.
2.
Immerse lower pump end or fl uid inlet hose into a bucket of
solvent.
3.
Turn air regulator pressure control knob and allow pump to
cycle.
4.
Circulate solvent through pump until it is thoroughly
cleaned.
GENERAL INFORMATION / LUBRICATION PISTON PUMP
long periods of time.
PLACING INTO SERVICE
START-UP
1.
Turn air regulator pressure control knob until motor starts to
cycle.
2.
Allow pump to cycle slowly until it is primed and all air is
purged from the fl uid hose or dispensing device.
3.
Turn off dispensing device and allow pump to stall. Re-check
the fi ttings and tighten if necessary.
4.
Open dispensing device and allow pump to re-start.
5.
Adjust the air regulator as required to obtain desired operat-
ing pressure and fl ow.
If the pump is equipped with a solvent cup; keep the solvent
cup fi lled with a compatible solvent. This will keep the mate-
rial from drying on the piston rod, which could drag through
the packings, ruin them and eventually scour the piston rod.
Use Aro Part No. 637153-B Wet-Sol "Plus" Kit to remove dirty or
contaminated solvent and replenish with new solvent.
SHUTDOWN
It is good practice to periodically fl ush entire pump system
with a solvent that is compatible with the material being
pumped, especially if the material being pumped is subject to
"settling-out" when not in use for a period of time.
Disconnect the air supply from the pump if it is to be inactive
for a few hours.
Keep good records of service activity and include pump in
preventive maintenance program.
Check the material and air hoses for any weakness, and re-
place if necessary.
USE ONLY GENUINE ARO REPLACEMENT PARTS TO ASSURE
PERFORMANCE AND PRESSURE RATING.
Repairs should be made only by authorized trained personnel.
Contact your local authorized ARO Service Center for parts
and customer service information. Refer to page 3.