Herunterladen Inhalt Inhalt Diese Seite drucken

Figure 3-7 Sensor; Figure 3-8 Sensor Installation - Siemens SITRANS F Quick Start Betriebsanleitung

Ultraschall-durchflussmessgeräte
Vorschau ausblenden Andere Handbücher für SITRANS F:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Connecting
3.3 Installing the Sensor
Installing the Sensor
1. Apply a continuous 3mm (1/8-inch) bead of couplant compound across the center (the
2. Place the sensor on the pipe center in the middle of one of the areas you have cleaned.
28
long way) of the sensor emitting surface.
Coupling Compound
Emitting Surface
Back End
Figure 3-7
Sensor
Front View
Spring Clip (Not present on some
models)
Sensor Clamping Screw
Spacer Bar
7ME39600M Mounting Frame
Figure 3-8
Sensor Installation
Make sure its cable connector is pointing away from the other cleaned area.
Sensor
Angled Edge
F-Connector
Pipe
Mounting Strap Note: Optional 2nd
Mounting Strap shown. Larger pipes,
over 76cm (30 inches) may need
additional support.
Spacer Bar Platform and Clamping
Screw
Spacer Bar Reference Hole
Orientation of sensor at 9 o'clock position
FST020 IP65 NEMA 4X Quick Start
Operating Instructions, 03/2012, A5E03086489-05

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Sitrans fst020 ip65 nema 4x

Inhaltsverzeichnis